The new revision of the main instrument transformer standard, IEC 61869-1:2023, premiered requirements for the performance of instrument transformers in terms of transfer accuracy at higher frequencies. Five accuracy class extensions were introduced to establish an explicit performance level. Each of the extension levels has a distinct bandwidth and accuracy performance associated with it. While these requirements are mainly aimed at non-conventional instrument transformers, the hypothesis of this paper is that conventional high-voltage instrument transformers can have a performance conformant to the above-mentioned requirements. Specifically, the focus of this paper will be on open-core inductive voltage transformers, which inherently exhibit an improved frequency response in comparison to their conventional closed-core counterparts. The main aim of this paper is to present a relevant transformer model based on a lumped parameter equivalent diagram. This model considers the actual mutual coupling (both capacitive and inductive) of the transformer windings. The model is created in EMTP software, and the output yields a frequency response characteristic of the transformer. The model will be validated with test results obtained through measurements on actual 123 kV, 245 kV, and 420 kV inductive voltage transformers.

13 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZJZvonimir Jurković
Zvonimir Jurković
Bruno JurisicBruno Jurisic
Bruno Jurisic
TOMISLAV ZUPANTOMISLAV ZUPAN
TOMISLAV ZUPAN
A multi-step approach for the fast calculation of the magnetic field inside transformer tank shields, based on the 2D FEM, is presented in the paper. Due to the limitations of the 2D FEM, the proposed approach utilizes several 2D FEM models and calculates the magnetic field in multiple steps to account for the 3D geometry of the problem. In the first step, a distribution of the magnetic flux density that enters the tank shields is calculated using the quasi-3D model of the transformer. This quasi-3D model is obtained by superimposing the solution of multiple axisymmetric 2D FEM models, and assumes a considerably simplified transformer geometry. To account for the tank shield geometry that is neglected in the quasi-3D FEM model, an additional 2D FEM model with tank shields is introduced. After the distribution of the magnetic flux density that enters the tank shields is calculated, it is imposed in the final 2D FEM model with a non-linear tank shield which is used to calculate the magnetic flux density distribution inside the tank shields. The proposed approach enables a fast calculation of magnetic field distributions, both in the vertical and horizontal directions. The results of the proposed approach are compared against the 3D FEM. The relative error of the maximum magnetic flux density is under 2%, while the NRMSE of the magnetic flux density distribution within the tank shields is under 10%. The key contribution of the proposed approach is a low computation time. In the presented case study, the total computation time of the proposed approach is ~30 s, while the computation time of the 3D FEM is ~1 h. As the computation time is significantly reduced, while the accuracy is acceptable, the proposed approach can be a good alternative to the 3D FEM for design purposes. Therefore, it has industrial value.

23 February 2023 in Journal of Energy - Energija
Verified
Journal Article
Open access
PDF file
Bruno JurisicBruno Jurisic
Bruno Jurisic
TOMISLAV ZUPANTOMISLAV ZUPAN
TOMISLAV ZUPAN
MJMario Jurić
Mario Jurić
BFBožidar Filipović-Grčić
Božidar Filipović-Grčić
KMKatarina Musulin
Katarina Musulin
During their lifespan all the primary equipment installed in power system is subjected to transients. Therefore, it is necessary to adequately dimension and protect the equipment. However, in the networks with high share of renewables, power electronics, cables or near GIS, the failure can occur even though good practice of insulation coordination are fulfilled. In this paper high frequency power transformer model is presented. Such model is based on measurements of admittance matrix and is adequate for simulation of fast front transient in EMTP like software. Additionally, simulations of lightning and switching overvoltages are given for the observed power transformer unit.

28 November 2019
Verified
Book Chapter
Closed access
PDF file
Bruno JurisicBruno Jurisic
Bruno Jurisic
TŽTomislav Župan
Tomislav Župan
LŠLeonardo Štrac
Leonardo Štrac

12 November 2025 in arXiv
Verified
Preprint
Open access
PDF file
IRIva Radecic
Iva Radecic
BFBozidar Filipovic-Grcic
Bozidar Filipovic-Grcic
PAPaul Akiki
Paul Akiki
AXAlain Xemard
Alain Xemard
Bruno JurisicBruno Jurisic
Bruno Jurisic
HVDC networks offer several advantages over traditional HVAC systems, particularly for long-distance power transmission and integration of renewable energy sources, such as reduced losses and enhanced stability and control, but also increase the risk of oscillations. This study investigates electrical resonant phenomena associated with HVDC stations through numerical EMT simulations. The findings indicate that electrical resonance is primarily pronounced in weak networks with long cables, as confirmed by the Nyquist criterion applied to frequency responses. Two real cases were successfully simulated in the time domain by introducing network changes, such as temporary faults and alterations in network's power strength, to activate the identified resonances. Notably, in a strong network with short cables, electrical resonance occurred alongside interactions between the network and the converter's protection system. The analysis of voltage waveforms revealed that the amplitude of the induced resonant harmonic dissipates quickly, indicating sufficient damping in the network configuration. Furthermore, the study confirmed the network's sensitivity to changes in converter parameters modeled using available MMC model.

9 November 2025 in arXiv
Verified
Preprint
Open access
PDF file
NSNina Stipetic
Nina Stipetic
BFBožidar Filipović-Grčić
Božidar Filipović-Grčić
IZIgor Ziger
Igor Ziger
SJSilvio Jancin
Silvio Jancin
Bruno JurisicBruno Jurisic
Bruno Jurisic
AXAlain Xémard
Alain Xémard
Unearthed neutral is commonly used in networks which require continuous power supply. This is common in MV circuits of industrial and power plants. Unearthed networks can remain in operation during an earth-fault, but fast determination of the faulty line is key for prevention of further fault escalation. Signal injection is one of the fault location methods often used in LV unearthed networks. The possibility of applying this method in MV networks depends on how to inject the signal into unearthed phases. In such networks, it is possible to use a group of three inductive voltage transformers (IVTs) for signal injection. After the simulations have shown promising results of signal injection and earth-fault detection in MV network, an experimental test was performed. This paper describes the experimental setup and shows the measurement results of signal injection method at MV level supported by EMT simulations.