It is significant for people with diabetes to know their body’s real-time glucose level, which can guide the diagnosis and treatment. Therefore, it is necessary to research continuous glucose monitoring (CGM) as it gives us real-time information about our health condition and its dynamic changes. Here, we report a novel hydrogel optical fiber fluorescence sensor segmentally functionalized with fluorescein derivative and CdTe QDs/3-APBA, which can continuously monitor pH and glucose simultaneously. In the glucose detection section, the complexation of PBA and glucose will expand the local hydrogel and decrease the fluorescence of the quantum dots. The fluorescence can be transmitted to the detector by the hydrogel optical fiber in real time. As the complexation reaction and the swelling–deswelling of the hydrogel are all reversible, the dynamic change of glucose concentration can be monitored. For pH detection, the fluorescein attached to another segment of the hydrogel exhibits different protolytic forms when pH changes and the fluorescence changes correspondingly. The significance of pH detection is compensation for pH errors in glucose detection because the reaction between PBA and glucose is sensitive to pH. The emission peaks of the two detection units are 517 nm and 594 nm, respectively, so there is no signal interference between them. The sensor can continuously monitor glucose in 0–20 mM and pH in 5.4–7.8. The advantages of this sensor are multi-parameter simultaneous detection, transmission-detection integration, real-time dynamic detection, and good biocompatibility.
Fiber Bragg grating (FBG) array, consisting of a number of sensing units in a single optical fiber, can be practically applied in quasi-distributed sensing networks. Serious signal crosstalk occurring between large-serial of identical FBGs, however, has limited the further increase in the number of sensing units, thus restricting applications only for short-distance sensing networks. To reduce the signal crosstalk, we design two novel types of 10-kilometer-long FBG arrays with 10 000 equally spaced gratings, written on-line using a customized grating inscription system, which is affiliated to a drawing tower. Main factors causing signal crosstalk, such as spectral shadowing and multiple reflections, are firstly investigated in theory. Consistent with the theoretical findings, experimental results are proving that ultra-weak (the reflectivity of ∼−40 dB) and multi-wavelength gratings of a number more than 10 000 can be readily identified, with satisfied low crosstalk. The maximum attenuation of grating signal and minimum signal-to-noise ratio (SNR) in a single-wavelength array are 10.69 dB and 5.62 dB, respectively. As a comparison, by increasing the number of central wavelengths to three, the attenuation can be effectively reduced to 5.54 dB and the minimum SNR has been improved to 8.14 dB. The current study significantly enhances the multiplexing capacity of FBG arrays and demonstrates promising potentials for establishing large-capacity quasi-distributed sensing networks.
A Fabry-Perot interferometric sensor for temperature measurement was fabricated based on a silica glass solid-core photonic crystal fiber with a central air-bore. By splicing a stub of photonic crystal fiber to a standard single-mode fiber, an intrinsic Fabry-Perot cavity was formed inside the photonic crystal fiber. Sensing experiment results show that the sensor can work stably for a consecutive 24 h under temperatures up to 1100 °C, and the short-term operation temperature can reach as high as 1200 °C (<30 min). In the measurement range of 300–1200 °C, the temperature sensitivity of the peak wavelength shift can reach as high as 15.61 pm/°C, with a linearity of 99.76%. The presented interferometric sensor is compact in size and possesses advantages such as an extended working range and high sensitivity, showing promising application prospects.
This article presents a high-speed distributed vibration sensing based on Mach-Zehnder-OTDR (optical time-domain reflectometry). Ultra-weak fiber Bragg gratings (UWFBG), whose backward light intensity is 2-4 orders of magnitude higher than that of Rayleigh scattering, are used as the reflection markers. A medium-coherence laser can substitute conventional narrow bandwidth source to achieve an excellent performance of distributed vibration sensing since our unbalanced interferometer matches the interval of UWFBGs. The 3 m of spatial resolution of coherent detection and multiple simultaneous vibration sources locating can be realized based on OTDR. The enhanced signal to noise ratio (SNR) enables fast detection of distributed vibration without averaging. The fastest vibration of 25 kHz and the slowest vibration of 10 Hz can be detected with our system successfully, and the linearity is 0.9896 with a maximum deviation of 3.46 nƐ.
We demonstrate distributed acoustic sensor using broadband weak fiber Bragg grating (bwFBG) array for large temperature tolerance in an φ-OTDR system with a balanced Michelson interferometer. The system was tested with large difference in local temperature, 18 °C and 50 °C, simultaneously, and achieves a relatively flat frequency response from 20 Hz to 1200 Hz.