Andreas Ernst

Mr. Andreas Ernst


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2013 in Micromachines
Verified
Journal Article
Open access
PDF file
SBStefan Bammesberger
Stefan Bammesberger
SKSabrina Kartmann
Sabrina Kartmann
LTLaurent Tanguy
Laurent Tanguy
DLDong Liang
Dong Liang
KMKlaus Mutschler
Klaus Mutschler
PKPeter Koltay
Peter Koltay
We present a disposable, normally closed, non-contact dispensing valve for the sub-µL range. The miniaturized solenoid valve (diameter: 8 mm, height: 27.25 mm) is compatible to standard Luer-Lock interfaces. A highly dynamic actuation principle enables opening times down to 1 ms. The dispensing performance was evaluated for water (η = 1.03 mPas) and a 66% (w/w) glycerol/water solution (η = 16.98 mPas), at pressures varying from 200 to 800 mbar. The experimentally determined minimal dispensing volume was 163 nL (CV 1.6%) for water and 123 nL (CV 4.5%) for 66% (w/w) glycerol/water. The low-cost polymer valve enables high precision dispensing of liquid volumes down to the lower end of the sub-µL range comparable to high-end non-disposable micro-dispensing valves.

3 August 2012 in Sensors
Verified
Journal Article
Open access
PDF file
AEAndreas Ernst
Andreas Ernst
KMKlaus Mutschler
Klaus Mutschler
LTLaurent Tanguy
Laurent Tanguy
NPNils Paust
Nils Paust
RZRoland Zengerle
Roland Zengerle
PKPeter Koltay
Peter Koltay
In this paper a multi-disciplinary simulation of a capacitive droplet sensor based on an open plate capacitor as transducing element is presented. The numerical simulations are based on the finite volume method (FVM), including calculations of an electric field which changes according to the presence of a liquid droplet. The volume of fluid (VOF) method is applied for the simulation of the ejection process of a liquid droplet out of a dispenser nozzle. The simulations were realised using the computational fluid dynamic (CFD) software CFD ACE+. The investigated capacitive sensing principle enables to determine the volume of a micro droplet passing the sensor capacitor due to the induced change in capacity. It could be found that single droplets in the considered volume range of 5 nL < Vdrop < 100 nL lead to a linear change of the capacity up to ΔQ < 30 fC. The sensitivity of the focused capacitor geometry was evaluated to be Si = 0.3 fC/nL. The simulation results are validated by experiments which exhibit good agreement.