In an attempt to improve the performance of underactuated robotic hands in grasping, we investigate the influence of the underlying coupling mechanism on the robustness of underactuated hands to external disturbance. The coupling mechanisms used in underactuated mechanisms can be divided into two main classes based on the self-adaptive transmission used to route actuation to the degrees of freedom, namely single-acting and double-acting transmissions. The kinematic coupling constraint is always active in double-acting mechanisms, while there are specific combinations of external disturbances and mechanism parameters that render the constraint inactive in single-acting mechanisms. This paper identifies unique behaviors in terms of mechanism reconfiguration and variation in grasping contact forces that result from the underactuated hand’s response to external disturbance forces and show that these behaviors are a function of the coupling mechanism, actuation mode, and contact constraints. We then present an analysis of how these behaviors influence grasping ability of the hand and discuss implications for underactuated hand design and operation.
15 August 2019 in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
Image dehazing is an essential preprocessing stage for several applications such as surveillance, long-range imaging, automatic driver-assistance system (ADAS), and remote sensing. Haze particles degrade visible-band images more severely than the infrared images due to scattering phenomena. Therefore, infrared data can be effectively utilized to enhance the visibility of color images captured in a hazy environment. In this brief, for the first time, a multispectral transmission map fusion approach is presented, wherein a haze-aware weight generation scheme is used to improve transmission map in specific regions. This achieves significant quantitative improvement as compared with the existing methods. In addition, the method is extremely suitable for hardware implementation. Therefore, a low-cost very large-scale integration (VLSI) architecture is also presented. The application-specified integrated circuit (ASIC) and field-programmable gate array (FPGA) implementations dissipate 3.45- and 57-mW power at 150 MHz, respectively. Both ASIC and FPGA achieve a high throughput of 450 and 308 Mpixels/s, respectively. The design does not require any external memory such as dynamic random access memory, thus making it suitable for on-chip processing that can be closely integrated with an image sensor.
With the goal of improving the performance of underactuated robotic hands in grasping, we investigate the influence of the underlying coupling mechanism on the robustness of underactuated hands to external disturbance. This paper identifies unique behaviors in the hand’s response as a function of the coupling mechanism and the actuation mode the hand is operated in. Specifically, we show that in conditions when the actuator position is fixed, hands with single-acting mechanisms exhibit a bimodal behavior in contrast to hands with double-acting mechanisms that exhibit a unimodal behavior. We then present an analysis of how these behaviors influence grasping capability of the hand and then discuss implications for underactuated hand design and operation.
The purpose of this study was to investigate if a new tendon transfer surgical procedure that uses an implanted passive engineering mechanism for attaching multiple tendons to a single donor muscle in place of directly suturing the tendons to the muscle improves hand function in physical interaction tasks such as grasping. The tendon transfer surgery for high median ulnar palsy was used as an exemplar, where all four flexor digitorum profundus (FDP) tendons are directly sutured to the extensor carpi radialis longus (ECRL) muscle to restore flexion. The new procedure used a passive hierarchical artificial pulley system to connect the muscle to the tendons. Both the suture-based and pulley-based procedures were conducted on N = 6 cadaver hands. The fingers’ ability to close around four objects when the ECRL tendon was pulled was tested. Post-surgery hand function was evaluated based on the actuation force required to create a grasp and the slip between the fingers and the object after the grasp was created. When compared with the suture-based procedure, the pulley-based procedure (i) reduced the actuation force required to close all four fingers around the object by 45 % and (ii) improved the fingers’ individual adaptation to the object’s shape during the grasping process and reduced slip by 52 % after object contact (2.99° ± 0.28° versus 6.22° ± 0.66°). The cadaver study showed that the implanted engineering mechanism for attaching multiple tendons to one muscle significantly improved hand function in grasping tasks when compared with the current procedure.