Dražen Čular

Prof. Dr. Dražen Čular

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
Dražen ČularDražen Čular
Dražen Čular
WDWissem Dhahbi
Wissem Dhahbi
IKIvo Kolak
Ivo Kolak
AIAntonio Dello Iacono
Antonio Dello Iacono
TBTea Bešlija
Tea Bešlija
JPJohnny Padulo
Johnny Padulo
Čular, D, Dhahbi, W, Kolak, I, Iacono, AD, Bešlija, T, Laffaye, G, and Padulo, J. Reliability, sensitivity, and minimal detectable change of a new specific climbing test for assessing asymmetry in reach technique. J Strength Cond Res 35(2): 527–534, 2021—The aims of this study were to establish intertrial and intersession reliability, sensitivity, and minimal detectable change of a new climbing test specifically for assessing asymmetry in reach technique (TEST). Twenty-four young climbers (16 males and 8 females) participated in this study. The protocol consisted of performing, in counterbalanced random order, 3 tests; TEST, maximum handgrip force, and squat on the bench, in 2 sessions (with 3 trials for each session). TEST performance was expressed as: TEST performance for left hand (TESTL), TEST performance for right hand (TESTR), and absolute symmetry index (ASI). For intertrial and intersession reliability assessment, TESTL and TESTR showed excellent reliability (intraclass correlation coefficients ranged: 0.96–1.00; SEM% ranged: 0.07–1.23; and coefficient of variation—CV%: 1.28–2.53). In addition, SEMs were smaller than the smallest worthwhile change (SWC) values (SWC% = 1.07 and 0.99 for TESTL and TESTR, respectively), and the minimal detectable change (MDC95) for both sides was small ( SWC% = 8.40 and CV% = 41.98). Pairwise test comparisons revealed no difference between sides. Considering the high reliability and the satisfactory sensitivity, TEST can be used to define individual asymmetry in the performance of the reach technique to the left or the right body side in climbers. However, interpreting data using the ASI index requires caution because it had poor absolute reliability and marginal sensitivity.

14 July 2020 in Frontiers in Sports and Active Living
Verified
Journal Article
Open access
PDF file
Luca Paolo ArdigòLuca Paolo Ardigò
Luca Paolo Ardigò
Stefano PalermiStefano Palermi
Stefano Palermi
Johnny PaduloJohnny Padulo
Johnny Padulo
WDWissem Dhahbi
Wissem Dhahbi
Luca RussoLuca Russo
Luca Russo
MTMario Tomljanovic
Mario Tomljanovic
Post-exercise recovery is a complex process involving a return of performance and a physiological or perceptual feeling close to pre-exercise status. The hypothesis of this study is that the device investigated here is effective in evaluating the recovery state of professional cyclists in order to plan effective training. Ten professional male cyclists belonging to the same team were enrolled in this study. Participants performed a 7-day exercise program [D1, D4, and D7: low-intensity training; D2 and D5: passive recovery; D3: maximum oxygen consumption (VO2Max) test (for maximum mechanical power assessment only); and D6: constant load test]. During the week of monitoring, each morning before getting up, the device assessed each participant's so-called Organic Readiness {OR [arbitrary unit (a.u.)]}, based on blood pressure (BP), heart rate (HR), features of past exercise session, and following self-perceived condition. Based on its readings and algorithm, the device graphically displayed four different colors/values, indicating general exercise recommendations: green/3 = “you can train hard,” yellow/2 = “you can train averagely,” orange/1 = “you can train lightly,” or red/0 = “you should recover passively.” During the week of research, morning OR values and Bonferroni post-hoc comparisons showed significant differences between days and, namely, values (1) D2 (after low intensity training) was higher than D4 (after VO2Max test; P = 0.033 and d = 1.296) and (2) D3 and D6 (after passive recovery) were higher than D4 (after VO2Max test; P = 0.006 and d = 2.519) and D5 (after low intensity training; P = 0.033 and d = 1.341). The receiver operating characteristic analysis area under curve (AUC) recorded a result of 0.727 and could differentiate between D3 and D4 with a sensitivity and a specificity of 80%. Preliminarily, the device investigated is a sufficiently effective and sensitive/specific device to assess the recovery state of athletes in order to plan effective training.

15 May 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Dražen ČularDražen Čular
Dražen Čular
VIVladimir Ivančev
Vladimir Ivančev
AZAlessandro M. Zagatto
Alessandro M. Zagatto
MMMirjana Milić
Mirjana Milić
TBTea Beslija
Tea Beslija
Johnny PaduloJohnny Padulo
Johnny Padulo
Cycling test such Wingate anaerobic test (WAnT) is used to measure anaerobic power (AP), but not anaerobic capacity (AC, i.e., the metabolic energy demand). However, in sports that do not involve cycling movements (Karate), the continuous jump for 30 s (vertical jumps for 30 s) has been extensively used to measure anaerobic performance in all young athletes. Limited information’s are available concerning its validity and reliability especially in children. As such, the current study aimed to test validity and reliability of a continuous jumps test (the CJ30s), using WAnT as a reference. Thirteen female Karate kids (age: 11.07 ± 1.32 years; mass: 41.76 ± 15.32 kg; height: 152 ± 11.52 cm; training experience: 4.38 ± 2.14 years) were tested on three separate sessions. The first and second sessions were used to assess the reliability using Intra-class correlation coefficient (ICC) of CJ30s, whereas on the third session WAnT was administered. Following CJ30s and WAnT, we assessed AP (1/CJ30s, as jump height [JH], fatigue index [FI], and blood lactate [BL]; 2/WAnT, as mechanical power [P], FI, and BL) and AC as the excess post-exercise oxygen consumption (EPOC). Large/highly significant correlations were found between CJ30s and WAnT EPOCs (r = 0.730, P = 0.003), and BLs (r = 0.713, P = 0.009). Moderate/significant correlations were found between CJ30s and WAnT FIs (r = 0.640, P = 0.014), CJ30s first four jumps mean JH and WAnT peak P (r = 0.572, P = 0.032), and CJ30s mean JH and WAnT mean P (r = 0.589, P = 0.021). CJ30s showed excellent and moderate reliability (ICC) for AP (maximal JH 0.884, mean JH 0.742, FI 0.657, BL 0.653) and AC (EPOC 0.788), respectively. Correlations observed especially in terms of AC between CJ30s and WAnT provide evidence that former may adequately assess anaerobic performance for the young combat athlete. CJ30 is a reliable test and allow an easy assessment of AP and AC in karate children.

14 October 2019 in Research Quarterly for Exercise and Sport
Verified
Journal Article
Closed access
MJMario Jeličić
Mario Jeličić
VIVladimir Ivančev
Vladimir Ivančev
Dražen ČularDražen Čular
Dražen Čular
NČNedim Čović
Nedim Čović
ESEmilija Stojanović
Emilija Stojanović
ZMZoran Milanović
Zoran Milanović
Purpose: The purpose of this study was to determine the reliability, validity, and usefulness of 30–15 Intermittent Fitness Test (30-15IFT) in female basketball players. Methods: Nineteen female basketball players (17.82 ± 1.94 yr, 175.4 ± 7.3 cm, 67.9 ± 7.7 kg) competing in the National Croatian League performed one trial of a continuous treadmill running test and two trials of the 30-15IFT. The 30-15IFT involves 30-s runs across a 40-m course interspersed with 15 s of walking, with running speed increasing every 45 s. The continuous treadmill running test was used as the criterion for validation. Results: High to very high reliability across test–retest trials were observed for maximal oxygen uptake (VO2max) (CV = 4.9%, ICC = 0.85), the 30-15IFT end-running velocity (VIFT) (CV = 6.0%, ICC = 0.85), and maximal heart rate (HRmax) (CV = 4.8%, ICC = 0.96). Criterion validity was supported for the 30-15IFT with strong to very strong relationships with VO2max (r =0.69), VIFT (r =0.74), and HRmax (r =0.73) attained during the continuous treadmill running test. The typical error (TE) of the 30-15IFT was greater than the smallest worthwhile change for VO2max (1.16 > 0.42 ml/kg/min), VIFT (0.56 > 0.20 km/h), and HRmax (2.15 > 1.89 bpm) adjudging usefulness of the test as marginal. The TE of 0.56 km/h (90% CI = 0.44–0.77 km/h) demonstrates changes in the performance of one to two stages (0.5–1.0 km/h) are meaningful. Conclusions: The 30-15IFT possesses acceptable reliability and validity to assess maximal aerobic fitness capacity in female basketball players. While the usefulness of the 30-15IFT was marginal, meaningful changes in performance consisted of only one to two stages. The present findings support the 30-15IFT as a practical testing option for basketball practitioners to assess fitness capacities in female players.

30 October 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
JPJohnny Padulo
Johnny Padulo
Luca Paolo ArdigòLuca Paolo Ardigò
Luca Paolo Ardigò
MBMassimo Bianco
Massimo Bianco
Dražen ČularDražen Čular
Dražen Čular
DMDejan Madic
Dejan Madic
WDWissem Dhahbi
Wissem Dhahbi
Main aim of this study was examining validity and reliability of using a new specific Parkour repeated sprint ability test (SPRSA) for assessing repeated sprint ability while facing obstacles and establishing between-day reliability and sensitivity of SPRSA related to its physiological and performance responses. Thirteen high-level traceurs (three females) performed in random order and twice eight tests for assessing a total of 23 variables: SPRSA (a typical maximal-speed shuttle run interspersed with four Parkour competition-common fundamentals) and seven established fitness tests, core stability, hand-grip, vertical-jump, long-jump, pull-up, 300-m shuttle run (as a field test for anaerobic capacity), and Leger test. Except for muscular elasticity index of vertical jump test (intra-class Correlation Coefficient model 3,1 [ICC3,1] = 0.54 [fair]), fitness tests’ ICC3,1s resulted excellent (ICC3,1: 0.93–1.00). SPRSA total time and time of its fastest sprint (SPRSA peak time) were significantly correlated with the majority of core stability (r: −0.79 to 0.59; P < 0.01–0.05), jumping (r: −0.78 to 0.67; P < 0.01–0.05), pull-up tests (r: −0.86; P < 0.01), 300-m shuttle run test total time (r: 0.77–0.82; P < 0.01), and Leger test-estimated VO2 max (r: −0.78; P < 0.01). Principal component analysis (PCA) of the 23 variables led to extraction of four significant components (each due to different variables’ combinations), which explained 90.2% of 23 variables’ total variance. SPRSA (i.e., total and peak time) showed high reliability (ICC3,1: 0.991–0.998 and standard-error-of-measurement %: 0.07–0.32). Finally, SPRSA showed high sensitivity (smallest-worthwhile-change %: 0.29–0.68). Considering its excellent logical and strong ecological validity, SPRSA may serve as a valid specific field test for Parkour sport. In addition, thanks to its high reliability and sensitivity, this test is suitable for monitoring, evaluating, and programming training processes for Parkour practitioners in repeated sprint ability involving crossing obstacles.

Johnny PaduloJohnny Padulo
Johnny Padulo
Nebojša TrajkovićNebojša Trajković
Nebojša Trajković
Dražen ČularDražen Čular
Dražen Čular
ZGZoran Grgantov
Zoran Grgantov
DMDejan M M Madic
Dejan M M Madic
Luca RussoLuca Russo
Luca Russo
There is a strong need for a new, probably cheaper, smaller, and more portable isometric dynamometer. With this aim, we investigated the concurrent validity and reliability of a low-cost portable dynamometer to measure the isometric strength of the lower limb. Seventeen young participants (age 16.47 ± 0.51 years) were randomly assessed on three different days for knee flexion and extension isometric forces with two different devices: a commonly used isokinetic dynamometer (ISOC) and a portable isometric dynamometer prototype (ISOM). No significant differences were observed between the ISOC and the ISOM (all comparisons p > 0.05). Test–retest comparison showed the ISOM to have high reliability (ICC 0.879–0.990). This study showed that measurements with the ISOM could be performed without systematic bias and with high reliability. The ISOM is a device that is able to assess knee isometric strength with excellent concurrent validity and reliability.