Nicholas Wojtynek

Nicholas Wojtynek

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2020 in WIREs Nanomedicine and Nanobiotechnology
Verified
Journal Article
Closed access
PDF file
NWNicholas Wojtynek
Nicholas Wojtynek
AMAaron Mohs
Aaron Mohs

1 August 2020 in Molecular Cancer Therapeutics
Verified
Journal Article
Open access
PDF file
MOMadeline T. Olson
Madeline T. Olson
NWNicholas Wojtynek
Nicholas Wojtynek
GTGeoffrey Talmon
Geoffrey Talmon
TCThomas C. Caffrey
Thomas C. Caffrey
PRPrakash Radhakrishnan
Prakash Radhakrishnan
AMAaron Mohs
Aaron Mohs
Surgical resection is currently the only potentially curative option for patients with pancreatic cancer. However, the 5-year survival rate after resection is only 25%, due in part to high rates of R1 resections, in which cells are left behind at the surgical margin, resulting in disease recurrence. Fluorescence-guided surgery (FGS) has emerged as a method to reduce incomplete resections and improve intraoperative assessment of cancer. Mucin-16 (MUC16), a protein biomarker highly overexpressed in pancreatic cancer, is a potential target for FGS. In this study, we developed a fluorescent MUC16-targeted antibody probe, AR9.6-IRDye800, for image-guided resection of pancreatic cancer. We demonstrated the efficacy of this probe to bind human pancreatic cancer cell lines in vitro and in vivo. In an orthotopic xenograft model, AR9.6-IRDye800 exhibited superior fluorescence enhancement of tumors and lower signal in critical background organs in comparison to a nonspecific IgG control. The results of this study suggest that AR9.6-IRDye800 has potential for success as a probe for FGS in pancreatic cancer patients, and MUC16 is a feasible target for intraoperative imaging.

17 January 2023 in Separations
Verified
Journal Article
Open access
PDF file
YCYashpal Singh Chhonker
Yashpal Singh Chhonker
NWNicholas Wojtynek
Nicholas Wojtynek
PAPrachi Agrawal
Prachi Agrawal
AMAaron Mohs
Aaron Mohs
DMDaryl J Murry
Daryl J Murry
A selective, sensitive, and rapid liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitation of ICG in rat plasma. The chromatographic separation was achieved using an ACE excel C18 (3 µm, 50 × 3.0 mm) column, with a mobile phase composition of 0.1% formic acid and 0.1% formic acid in acetonitrile, using a gradient flow at a rate of 0.3 mL/min. The MS was operated at a unit resolution in the multiple reaction monitoring mode, using the precursor ion → product ion combinations of 753.3 → 330.2 m/z (ICG) and 747.45 → 717.50 (Cy7.5 amine) with a run time of 5 min. The assay was linear over a concentration range of 1–1000 ng/mL with a regression coefficient (r2) of 0.998 or better. The inter and intra-batch precision (% relative standard deviation, %RSD) was lower than 13.5%, with accuracy (%Bias) between −10.03% and 11.56%. The ICG was stable under laboratory storage and handling conditions. The validated method was successfully applied to preclinical pharmacokinetic (PK) studies of ICG at a dose of 0.39 mg/kg in rats. PK parameters suggested the highest plasma concentration within 2 min of intravenous dosing with restricted systemic distribution and rapid clearance.

3 April 2023
Verified
Other
Open access
MOMadeline T. Olson
Madeline T. Olson
NWNicholas Wojtynek
Nicholas Wojtynek
GTGeoffrey Talmon
Geoffrey Talmon
TCThomas C. Caffrey
Thomas C. Caffrey
PRPrakash Radhakrishnan
Prakash Radhakrishnan
AMAaron Mohs
Aaron Mohs
Supplementary Figure S2 shows the biodistribution of fluorescent conjugates in subcutaneous xenografts at 144 h post-injection.


3 April 2023
Verified
Other
Open access
MOMadeline T. Olson
Madeline T. Olson
NWNicholas Wojtynek
Nicholas Wojtynek
GTGeoffrey Talmon
Geoffrey Talmon
TCThomas C. Caffrey
Thomas C. Caffrey
PRPrakash Radhakrishnan
Prakash Radhakrishnan
AMAaron Mohs
Aaron Mohs
Supplementary Figure S1 shows the fluorescence imaging dynamics of AR9.6-IRDye800 in a Colo357 subcutaneous xenograft model.