Background: Addressing intraoperative bleeding remains a significant challenge in the field of robotic surgery. This research endeavors to pioneer a groundbreaking solution utilizing convolutional neural networks (CNNs). The objective is to establish a system capable of forecasting instances of intraoperative bleeding during robot-assisted radical prostatectomy (RARP) and promptly notify the surgeon about bleeding risks. Methods: To achieve this, a multi-task learning (MTL) CNN was introduced, leveraging a modified version of the U-Net architecture. The aim was to categorize video input as either “absence of blood accumulation” (0) or “presence of blood accumulation” (1). To facilitate seamless interaction with the neural networks, the Bleeding Artificial Intelligence-based Detector (BLAIR) software was created using the Python Keras API and built upon the PyQT framework. A subsequent clinical assessment of BLAIR’s efficacy was performed, comparing its bleeding identification performance against that of a urologist. Various perioperative variables were also gathered. For optimal MTL-CNN training parameterization, a multi-task loss function was adopted to enhance the accuracy of event detection by taking advantage of surgical tools’ semantic segmentation. Additionally, the Multiple Correspondence Analysis (MCA) approach was employed to assess software performance. Results: The MTL-CNN demonstrated a remarkable event recognition accuracy of 90.63%. When evaluating BLAIR’s predictive ability and its capacity to pre-warn surgeons of potential bleeding incidents, the density plot highlighted a striking similarity between BLAIR and human assessments. In fact, BLAIR exhibited a faster response. Notably, the MCA analysis revealed no discernible distinction between the software and human performance in accurately identifying instances of bleeding. Conclusion: The BLAIR software proved its competence by achieving over 90% accuracy in predicting bleeding events during RARP. This accomplishment underscores the potential of AI to assist surgeons during interventions. This study exemplifies the positive impact AI applications can have on surgical procedures.
YUYoung Research Group of the Italian Society of Urodynamics
Young Research Group of the Italian Society of Urodynamics
+10
Background: Minimally invasive surgery could improve cosmetic outcomes and reduce the risks of surgical injury with less postoperative pain and a quicker patient’s discharge. Recently, transvaginal natural orifice transluminal endoscopic surgery (vNOTES) has been introduced in urogynecology with exciting results. Evidence Acquisition: After PROSPERO registration (n°CRD42023406815), we performed a comprehensive literature search on Pubmed, Embase, and Cochrane CENTRAL, including peer-reviewed studies evaluating transvaginal natural orifice transluminal endoscopic surgery. No limits on time or type of study were applied. Evidence synthesis: Overall, 12 manuscripts were included in the analysis. Seven studies evaluated uterosacral ligament suspension, four studies evaluated sacral colpopexy, three evaluated sacrospinous ligament suspension, and one study evaluated lateral suspension. Overall success rates were high (>90%); however, definitions of success were heterogeneous. In terms of complication, most of the studies reported low-grade complications (Clavien–Dindo I and II); only two patients needed mesh removal because of mesh exposure. The risk of bias of the trials was rated in the medium to high-risk category. Conclusions: The present review highlights important initial results for vNOTES. Future randomized clinical trials are needed to better define its role in the management of urogynecological procedures.
More than ever, precision surgery is making its way into modern surgery for functional organ preservation. This is possible mainly due to the increasing number of technologies available, including 3D models, virtual reality, augmented reality, and artificial intelligence. Intraoperative surgical navigation represents an interesting application of these technologies, allowing to understand in detail the surgical anatomy, planning a patient-tailored approach. Automatic superimposition comes into this context to optimally perform surgery as accurately as possible. Through a dedicated software (the first version) called iKidney, it is possible to superimpose the images using 3D models and live endoscopic images during partial nephrectomy, targeting the renal mass only. The patient is 31 years old with a 28 mm totally endophytic right-sided renal mass, with a PADUA score of 9. Thanks to the automatic superimposition and selective clamping, an enucleoresection of the renal mass alone was performed with no major postoperative complication (i.e., Clavien–Dindo < 2). iKidney-guided partial nephrectomy is safe, feasible, and yields excellent results in terms of organ preservation and functional outcomes. Further validation studies are needed to improve the prototype software, particularly to improve the rotational axes and avoid human help. Furthermore, it is important to reduce the costs associated with these technologies to increase its use in smaller hospitals.
Selective clamping during robot-assisted partial nephrectomy (RAPN) may reduce ischemia-related functional impairment. The intraoperative use of 3D-virtual models (3DVMs) can improve surgical planning, resulting in a greater success rate for selective clamping. Our goal is to introduce a new generation of 3DVMs, which consider the perfusion volumes of the kidney. Patients listed for RAPN from 2021 to 2022 were recruited. A selective clamping strategy was designed and intraoperatively performed based on the specifically generated 3DVMs. The effectiveness of selective clamping was evaluated using near-infrared-fluorescence imaging (NIRF) and 3DVM. Perfusion areas extensions were compared, and relevant preoperative characteristics were analyzed. In 61 of 80 (76.25%) cases, selective clamping was performed. The concordance between the 3DVM areas and the NIRF-enhanced areas was verified (k = 0.91). According to the distribution of perfused areas crossing the tumor, there were one, two, three, four, and five crossing areas, with relative perfusion rates of 13.75%, 35%, 32.5%, 13.75%, and 5%, respectively. Lesion diameter and mesorenal location were the only factors related to a higher number (>3) of perfusion volumes crossing the lesion. The implementation of mathematical algorithms to 3DVMs allows for precise estimation of the perfusion zone of each arterial branch feeding the organ, leading to the performance of safe and effective pedicle management planning.