Wang Hui

Wang Hui


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2023 in Annals of Medicine
Verified
Journal Article
Open access
ZZZhang Zhijun
Zhang Zhijun
SHShu He
Shu He
YZYu Zhong
Yu Zhong
HZHairong Zou
Hairong Zou
LCLu Cai
Lu Cai
WHWang Hui
Wang Hui
This study aimed to compare the repeatability and diagnostic efficiency of shear wave elastography (SWE) while using coupling gel and gel pads in the diagnosis of superficial breast lesions. Two experienced sonographers, trained in SWE, used different methods to perform the maximum Young's modulus (Emax) measurement of the lesion while using coupling gel SWE and gel pad SWE at different time points. All 80 lesions were in the superficial layer of the breast. The interclass correlation coefficient (ICC) was calculated to evaluate the intraobserver and interobserver repeatability. Meanwhile, the receiver operating characteristic curve (ROC curve) was used to calculate the sensitivity, specificity and area under the curve of the two methods. In the 80 breast lesions, the intraobserver and interobserver reproducibility of SWE measurements using coupling gel were considered good, and the ICCs were 0.728 (95% CI: 0.509-0.813) and 0.702 (95% CI: 0.492-0.795), respectively. The intraobserver and interobserver reproducibility of the SWE measured by the gel pad were also considered good, and the ICCs were 0.745 (95% CI: 0.501-0.801) and 0.713 (95% CI: 0.498-0.802), respectively. The sensitivity, specificity and area under the curve were 0.711 and 0.737, 0.929 and 0.905, and 0.873 and 0.878, respectively. In the SWE measurement of superficial breast lesions, the use of a gel pad does not affect the repeatability and diagnostic efficiency of the measurement.

22 March 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
ZLZheng-Ying Li
Zheng-Ying Li
LCLu Cai
Lu Cai
ZZZhi-Jun Zhang
Zhi-Jun Zhang
HZHai-Rong Zou
Hai-Rong Zou
MHMei He
Mei He
WHWang Hui
Wang Hui
Objectives: The endometrium of most unexplained infertility (UI) patients has been altered histologically. Shear wave elastography (SWE) is utilized to assess the signature of living tissue. This study aimed to explore the value of SWE in evaluating endometrial receptivity (ER) in UI patients. Methods: In total, 59 UI patients (UI group) and 52 normal control women (NC group) who received fertility consultation in our hospital were included between January 2022 and June 2023. We divided them into the late-proliferative phase of UI group (LPUI; n = 59), mid-secretory phase of UI group (MPUI; n = 41), late-proliferative phase of NC group (LPNC; n = 52), and mid-secretory phase of NC group (MPNC; n = 45). Transvaginal ultrasonography and SWE were performed during the LP and MP. Endometrial thickness (EMT), uterine artery pulsatility index (UA-PI), endometrial mean elasticity (E-mean), and mean shear wave velocities (SWV-mean) were measured. Results: There were significant differences in E-mean, SWV-mean, EMT, and UA-PI between the UI group and the NC group during both the LP and MP (p MPNC vs MPUI < 0.05, p LPNC vs LPUI < 0.05). E-mean and SWV-mean decreased with increasing EMT but increased with increasing UA-PI (p < 0.05). The most effective parameter for evaluating ER in UI patients is the E-mean (AUC = 0.89). Conclusions: UI patients exhibited thinner endometrium, increased endometrial stiffness, and poor endometrial blood perfusion. E-mean was the most effective parameter to evaluate ER in UI patients. The study preliminarily proved that SWE is a promising non-invasive tool for evaluating the condition of endometrium. Critical relevance statement: This study aimed to explore the significance of endometrial elasticity measured by SWE in evaluating patients with UI. The findings revealed a correlation between EMT, UA-PI, and E-mean. Endometrial elasticity can serve as an effective indicator for predicting ER. Key points: 1. To explore the significance of endometrial elasticity in assessing patients with UI. 2. The endometrium of UI patient exhibited thinness, stiffness, and poor blood perfusion. 3. Endometrial elasticity serves as a valuable indicator for evaluating endometrial receptivity. Graphical

24 May 2024 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
HZHairong Zou
Hairong Zou
WHWang Hui
Wang Hui
YZYu Zhong
Yu Zhong
ZZZhang Zhijun
Zhang Zhijun
ZWZhigang Wang
Zhigang Wang
TSTingting Shang
Tingting Shang

14 October 2022 in Renal Failure
Verified
Journal Article
Open access
ZZZhang Zhijun
Zhang Zhijun
SHShu He
Shu He
WHWang Hui
Wang Hui
YZYu Zhong
Yu Zhong
HZHairong Zou
Hairong Zou
XGXuan Gao
Xuan Gao
To reduce the empirical dependence of ultrasound measurement of the cephalic vein diameter, improve the repeatability of measurements for inexperienced operators, and provide a new method for inexp...

19 February 2025 in Annals of Medicine
Verified
Journal Article
Open access
LCLu Cai
Lu Cai
ZLZhengying Li
Zhengying Li
ZZZhang Zhijun
Zhang Zhijun
WWWei Wang
Wei Wang
YCYiyi Cao
Yiyi Cao
WHWang Hui
Wang Hui
To investigate the correlation between idiopathic neonatal hyperbilirubinemia and ductus venosus closure time and to examine prenatal factors influencing DV closure in neonates. A total of 103 full-term hyperbilirubinemic neonates born between September 2022 and September 2023 were selected as the hyperbilirubinemia group, while 169 full-term healthy neonates were chosen as the control group. Neonates with other perinatal or maternal abnormalities were excluded. Ultrasonographic examinations monitored ductus venosus closure time. ductus venosus blood flow, umbilical vein blood flow, ductus venosus shunt fraction, middle cerebral artery pulsitility index, and estimated fetal weight at term were retrospectively analyzed to compare differences between the two groups. The correlation between neonatal serum total bilirubin and ductus venosus closure time, as well as prenatal influences on ductus venosus closure time in neonates, were evaluated. The hyperbilirubinemia group had significantly longer ductus venosus closure time than the control group (p < 0.05). A positive association was found between ductus venosus closure and elevated neonatal serum total bilirubin. Prenatal factors influencing ductus venosus closure time included ductus venosus shunt fraction and fetal weight, where lower fetal weight and higher ductus venosus shunt fraction were associated with a delayed ductus venosus closure in neonates. Ductus venosus closure time is positively correlated with idiopathic neonatal hyperbilirubinemia, suggesting a potential role in its development. Fetal weight and the ductus venosus shunt fraction during the fetal period appear to influence the timing of ductus venosus closure in neonates.

29 April 2025 in International Journal of Public Health and Medical Research
Verified
Journal Article
Open access
PDF file
YCYuanjie Chen
Yuanjie Chen
YGYawen Gui
Yawen Gui
XYXinyi Yu
Xinyi Yu
HMHaoran Ma
Haoran Ma
JGJiayi Guo
Jiayi Guo
WHWang Hui
Wang Hui
Shear wave elastography (SWE) is a new ultrasonic elastography technique that can quantitatively obtain the elastic modulus of biological tissue without additional operator pressure. Because SWE technology has the advantages of quantitative measurement, good repeatability and real-time dynamic observation, it has been widely used in the evaluation of liver, thyroid, breast, gynecology, musculoskeletal system, urinary system and other diseases. Especially in recent years, SWE has been more widely used in the musculoskeletal system. This article introduces the progress in the research and application of elastography in the musculoskeletal system and reviews the progress in the clinical research and application of SWE in the evaluation of muscles and tendons, peripheral nerves, joints and ligaments, soft tissues and muscle masses.