Faisal Iqbal

Mr. Faisal Iqbal

Korea University of Technology and Education
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
FIFaisal Iqbal
Faisal Iqbal
HDHussamud Din
Hussamud Din
BLByeungleul Lee
Byeungleul Lee
This paper presents the design, fabrication, and characterization of a highly sensitive, single drive multi-axis gyroscope. The multi-axis gyroscope allows for a wide bandwidth in all three axes (X, Y, Z) and exhibits high linearity. The fabricated multi-axis gyroscope was fabricated with a structural thickness of 30 µm and packaged at 100 mtorr using wafer level packaging. The fabricated multi-axis gyroscope has a small footprint of 1426 × 1426 µm2, making it one of the smallest multi-axis gyroscopes. A custom printed circuit board (PCB) was designed for the evaluation of the multi-axis gyroscope. The experimental results demonstrate that the gyroscope has a high sensitivity of 12.56   μ V / dps ,   17.13   μ V / dps and 25.79   μ V / dps in the roll (X-sense), pitch (Y-sense) and yaw (Z-sense) modes respectively. The scale-factor non-linearity of the gyroscope is less than 0.2 % for roll and pitch mode and 0.001 % for the yaw mode, in the full-scale range of ± 1500   deg / s . The multi-axis gyroscope demonstrates an angle random walk of 2.79   dps / Hz , 2.14   dps / Hz , and   1.42   dps / Hz , for the roll, pitch and yaw rate with the in-run bias stability 1.62   deg / s , 1.14   deg / s and 0.84   deg / s respectively.

14 December 2016 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
MSMuhammad Ali Shah
Muhammad Ali Shah
FIFaisal Iqbal
Faisal Iqbal
ISIbrar Ali Shah
Ibrar Ali Shah
BLByeungleul Lee
Byeungleul Lee
This paper reports on designing a single-structure triaxes MEMS capacitive gyroscope which is capable of measuring the three angular velocities on a single drive. A Z-shaped beam for the support of folded coupling spring has been applied to suppress the unwanted mode and decrease the stress effect at the spring ends. The unique coupling spring has changed the driving motion, due to which slide film damping in the driving mode has been reduced. This reduction can lead to higher performance of the sensor with less requirements on vacuum level which decreases the cost of fabrication. Simulation analysis has been performed in COMSOL Multiphysics and Matlab Simulink to finalize the design for fabrication. After finite element analysis, the driving, x-sensing, z-sensing, and y-sensing are, respectively, found to be 13.30 KHz, 13.40 KHz, 13.47 KHz, and 13.51 KHz.

29 July 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
HDHussamud Din
Hussamud Din
FIFaisal Iqbal
Faisal Iqbal
BLByeungleul Lee
Byeungleul Lee
In this paper, a new design technique is presented to estimate and reduce the cross-axis sensitivity (CAS) in a single-drive multi-axis microelectromechanical systems (MEMS) gyroscope. A simplified single-drive multi-axis MEMS gyroscope, based on a mode-split approach, was analyzed for cross-axis sensitivity using COMSOL Multiphysics. A design technique named the “ratio-matching method” of drive displacement amplitudes and sense frequency differences ratios was proposed to reduce the cross-axis sensitivity. Initially, the cross-axis sensitivities in the designed gyroscope for x and y-axis were calculated to be 0.482% and 0.120%, respectively, having an average CAS of 0.301%. Using the proposed ratio-matching method and design technique, the individual cross-axis sensitivities in the designed gyroscope for x and y-axis were reduced to 0.018% and 0.073%, respectively. While the average CAS was reduced to 0.045%, showing a reduction rate of 85.1%. Moreover, the proposed ratio-matching method for cross-axis sensitivity reduction was successfully validated through simulations by varying the coupling spring position and sense frequency difference variation analyses. Furthermore, the proposed methodology was verified experimentally using fabricated single-drive multi-axis gyroscope.

15 April 2020 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
HDHussamud Din
Hussamud Din
FIFaisal Iqbal
Faisal Iqbal
BLByeungleul Lee
Byeungleul Lee

9 April 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
FIFaisal Iqbal
Faisal Iqbal
BLByeungleul Lee
Byeungleul Lee
Microelectromechanical systems (MEMS) resonators require fast, accurate, and cost-effective testing for mass production. Among the different test methods, frequency domain analysis is one of the easiest and fastest. This paper presents the measurement uncertainties in electrostatically actuated MEMS resonators, using frequency domain analysis. The influence of the applied driving force was studied to evaluate the measurement variations in resonant characteristics, such as the natural frequency and the quality factor of the resonator. To quantify the measurement results, measurement system analysis (MSA) was performed using the analysis of variance (ANOVA) method. The results demonstrate that the resonant frequency ( f r ) is mostly affected by systematic error. However, the quality (Q) factor strongly depends on the applied driving force. To reduce the measurement variations in Q factor, experiments were carried out to study the influence of DC and/or AC driving voltages on the resonator. The results reveal that measurement uncertainties in the quality factor were high for a small electrostatic force.

1 April 2016
Verified
Conference Paper
Closed access
MSMuhammad Ali Shah
Muhammad Ali Shah
FIFaisal Iqbal
Faisal Iqbal
BLByeung-Leul Lee
Byeung-Leul Lee
This paper reports the design and analysis of a single drive mass three axis Microelectromechanical systems (MEMS) gyroscope. The proposed MEMS gyroscope contains a unique and simple coupling spring to couple the driving masses. Due to the use of this coupling spring, the stress effect on the spring ends is reduced as it is attached at two points with the driving mass. Moreover, the unwanted motions of the driving mass can be suppressed due to the use of the two spring beams for the support of the central spring. After FEA simulation using COMSOL Multiphysics tool, a first driving mode of the proposed design has been achieved. Other modes were achieved for the pitch, roll and yaw sensing parts. The simulated resonant frequencies are 15.20 kHz for the driving mode, 15.21 kHz for the pitch sensing mode, 15.32 kHz for the roll sensing mode and 15.59 kHz for the yaw sensing mode, respectively.