Anthony Gunderman

Mr. Anthony Gunderman


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AGAnthony Gunderman
Anthony Gunderman
RMRudy Montayre
Rudy Montayre
ARAshish Ranjan
Ashish Ranjan
YCYue Chen
Yue Chen
This paper provides an overview of current robot-assisted high-intensity focused ultrasound (HIFU) systems for image-guided therapies. HIFU is a minimally invasive technique that relies on the thermo-mechanical effects of focused ultrasound waves to perform clinical treatments, such as tumor ablation, mild hyperthermia adjuvant to radiation or chemotherapy, vein occlusion, and many others. HIFU is typically performed under ultrasound (USgHIFU) or magnetic resonance imaging guidance (MRgHIFU), which provide intra-operative monitoring of treatment outcomes. Robot-assisted HIFU probe manipulation provides precise HIFU focal control to avoid damage to surrounding sensitive anatomy, such as blood vessels, nerve bundles, or adjacent organs. These clinical and technical benefits have promoted the rapid adoption of robot-assisted HIFU in the past several decades. This paper aims to present the recent developments of robot-assisted HIFU by summarizing the key features and clinical applications of each system. The paper concludes with a comparison and discussion of future perspectives on robot-assisted HIFU.

19 April 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AGAnthony Gunderman
Anthony Gunderman
SSSaikat Sengupta
Saikat Sengupta
ESEleni Siampli
Eleni Siampli
DSDimitri Sigounas
Dimitri Sigounas
CKChristopher Kellner
Christopher Kellner
YCYue Chen
Yue Chen
Objective : We aim to develop and evaluate an MR-conditional concentric tube robot for intracerebral hemorrhage (ICH) evacuation. Methods: We fabricated the concentric tube robot hardware with plastic tubes and customized pneumatic motors. The robot kinematic model was developed using a discretized piece-wise constant curvature (D-PCC) approach to account for variable curvature along the tube shape, and tube mechanics modeling with friction to compensate torsional deflection of the inner tube. The MR-safe pneumatic motors were controlled using a variable gain PID algorithm. The robot hardware was validated in a series of systematic bench-top and MRI experiments, and the robot's evacuation efficacy was tested in MR-guided phantom trials. Results: The pneumatic motor was able to achieve a rotational accuracy of 0.32°±0.30° with the proposed variable gain PID control algorithm. The kinematic model provided a positional accuracy of the tube tip of 1.39±0.54 mm. The robot was able to evacuate an initial 38.36 mL clot, leaving a residual hematoma of 8.14 mL after 5 minutes, well below the 15 mL guideline suggesting good post-ICH evacuation clinical outcomes. Conclusion: This robotic platform provides an effective method for MR-guided ICH evacuation. Significance: ICH evacuation is feasible under MRI guidance using a plastic concentric tube, indicating potential feasibility in future animal studies.

10 February 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MAMilad Azizkhani
Milad Azizkhani
AGAnthony Gunderman
Anthony Gunderman
Isuru S. GodageIsuru S. Godage
Isuru S. Godage
YCYue Chen
Yue Chen
The objective of this letter is to investigate the dynamic control of a soft robotic arm. First, a modular soft robotic hardware and an affordable actuator-space encoder were presented. We then discussed the soft robot modeling, and adaptive passivity control strategy with stability proof. The proposed controller was tested in different operation scenarios, and compared to the standard PD feedback linearization control and passivity control. In all experimental settings, the adaptive passivity control scheme was able to achieve superior performance, even with significant modeling uncertainties and disturbances. The theoretical analysis and experimental validations of the proposed controller will pave the way toward the practical implementations of the soft robotic system in the dynamic scenarios.

10 April 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
AGAnthony Gunderman
Anthony Gunderman
MMMishek Musa
Mishek Musa
BGBenjamin O. Gunderman
Benjamin O. Gunderman
FBFilip Banovac
Filip Banovac
KCKevin Cleary
Kevin Cleary
YCYue Chen
Yue Chen
Radiofrequency ablation (RFA) is an effective minimally-invasive treatment used for a variety of solid tumor cancers, including lung, breast, kidney, pancreatic, and liver. However, effective RFA for abdominal tumors relies on accurate ablation needle targeting, which can be a challenging task due to respiratory motion. This paper presents the design, fabrication, modeling, and benchtop characterization of a CT-guided parallel robot, and a novel respiration motion compensation protocol (RMCP) for effective robot-assisted abdominal RFA needle placement. The robot consists of a Stewart platform with a friction drive roller insertion module for autonomous needle deployment. Strain energy models are used to predict needle insertion force, the primary technical contribution of this work, providing a mean error of 0.49±0.28 N. The free-space accuracy characterization experiments indicate that the robotic platform is able to provide a needle tip position and orientation accuracy of 2.00±0.75 mm and 0.81±0.48±, respectively. A dynamic targeting experiment using an ex-vivo liver indicates an improvement in position and orientation error of 57% and 30%, respectively, when using the proposed RMCP. Finally, an animal study using a sexually-mature swine undergoing assisted respiration at nine breaths per minute indicates a 77% reduction in additional insertion displacement when using the RMCP.

13 December 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
AGAnthony Gunderman
Anthony Gunderman
MAMilad Azizkhani
Milad Azizkhani
SSSaikat Sengupta
Saikat Sengupta
KCKevin Cleary
Kevin Cleary
YCYue Chen
Yue Chen
Magnetic resonance (MR) conditional actuators and encoders are the key components for MR-guided robotic systems. In this article, we present the modeling and control of our MR-safe pneumatic radial inflow motor and encoder. A comprehensive model is developed that considers the primary dynamic elements of the system, including: 1) motor dynamics, 2) pneumatic transmission line dynamics, and 3) valve dynamics. After model validation, we present a simplified third order model that facilitates design of a first order sliding mode controller (TO-SMC). Finally, the motor hardware is tested in a 7T MRI. No image distortion or artifacts were observed. We posit the MR-safe motor and dynamic model will lower the entry barriers for researchers interested in MR-guided robots and promote wider adoption of MR-guided robotic systems.

8 April 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
AGAnthony Gunderman
Anthony Gunderman
SSSaikat Sengupta
Saikat Sengupta
ZHZhefeng Huang
Zhefeng Huang
DSDimitri Sigounas
Dimitri Sigounas
COChima Oluigbo
Chima Oluigbo
YCYue Chen
Yue Chen
Stereotactic neurosurgery is a well-established surgical technique for navigation and guidance during treatment of intracranial pathologies. Intracerebral hemorrhage (ICH) is an example of various neurosurgical conditions that can benefit from stereotactic neurosurgery. As a part of our ongoing work toward real-time MR-guided ICH evacuation, we aim to address an unmet clinical need for a skull-mounted frameless stereotactic aiming device that can be used with minimally invasive robotic systems for MR-guided interventions. In this paper, we present NICE-Aiming, a Neurosurgical, Interventional, Configurable device for Effective-Aiming in MR-guided robotic neurosurgical interventions. A kinematic model was developed and the system was used with a concentric tube robot (CTR) for ICH evacuation in (i) a skull phantom and (ii) in the first ever reported ex vivo CTR ICH evacuation using an ex vivo ovine head. The NICE-Aiming prototype provided a tip accuracy of 1.41±0.35 mm in free-space. In the MR-guided gel phantom experiment, the targeting accuracy was 2.07±0.42 mm and the residual hematoma volume was 12.87 mL (24.32% of the original volume). In the MR-guided ex vivo ovine head experiment, the targeting accuracy was 2.48±0.48 mm and the residual hematoma volume was 1.42 mL (25.08% of the original volume).