Chang-Soo Kim

Dr. Chang-Soo Kim


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2016 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
SAShihab Adnan
Shihab Adnan
KLKwang-Man Lee
Kwang-Man Lee
MGMohammad Tayeb Ghasr
Mohammad Tayeb Ghasr
MOMatthew J. O'KEefe
Matthew J. O'KEefe
DDDelbert E. Day
Delbert E. Day
CKChang-Soo Kim
Chang-Soo Kim
A biodegradable glass material is utilized as a novel functional element of solid-state devices. A water-soluble borate glass substrate serves as the structural platform on which thin film device is built. The glass substrate completely dissolves in a saline solution in approximately 40 h. Intentional failure of the spiral device (RLC resonator circuit) as a result of rapid structural disintegration by dissolution is demonstrated in DC, AC, and RF ranges that agrees well with simulation. Adopting water-soluble glass elements is expected to be a viable approach to develop reliable all-inorganic biodegradable devices that are fully functional during an intended operational lifetime followed by rapid degradation.

20 January 2009 in IEEE Sensors Journal
Verified
Journal Article
Open access
RARaghu Ambekar
Raghu Ambekar
JPJongwon Park
Jongwon Park
DHDavid B. Henthorn
David B. Henthorn
CKChang-Soo Kim
Chang-Soo Kim
A new class of optical oxygen sensor that can be photopatternable by traditional UV lithography is presented. They are fabricated using photopatternable spin-on silicone (polydimethylsiloxane, PDMS) with oxygen sensitive luminescent dyes. It has a good adhesion property and can be applied on glass or on photopolymer (SU-8) without any additional surface treatments. The optimum mixture composition for patternable oxygen sensitive membranes is investigated and its optical properties are characterized. Proof-of-concepts for two applications, intensity-based oxygen sensing with SU-8 based structure and self-calibration fluidic oxygen sensor, are described. These photopatternable optical membranes will find many applications wherever small patterns of oxygen sensitive membranes are required.

22 March 2006
Verified
Conference Paper
Closed access
JPJongwon Park
Jongwon Park
CKChang-Soo Kim
Chang-Soo Kim
SZShanrui Zhang
Shanrui Zhang
MCMinsu Choi
Minsu Choi
Recent developments for biosensors have been mainly focused on miniaturization and exploratory use of new materials. It should be emphasized that the absence of a novel "in-situ self-calibration/diagnosis technique" that is not connected to an external apparatus is a key obstacle to the realization of a biosensor for continuous use with minimum attendance. In order to address this issue, a novel solid-state glucose oxidase-coupled amperometric biosensor with integrated electrochemical actuation system has been designed and validated. There are two key components of the proposed glucose biosensor: solid-state GOD-coupled thin-1m amperometric sensing element and O2 depleting/saturating built-in electrochemical actuator. The actuator can be used to accomplish in-situ 1-point self-calibration by depleting O2 (i.e., by simulating glucose-free environment). Also, it can be used at the same time to extend the proposed sensor's linear detection range by increasing O2 (i.e., by enhancing glucose sensitivity). A prototype sensor was fabricated and a series of lab experiments was conducted. Collected data assures that the proposed sensor effectively establishes the zero calibration point and significantly enhances its measurement sensitivity and confidence

18 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MBMousumi Bose
Mousumi Bose
JHJason Hagerty
Jason Hagerty
JBJason Boes
Jason Boes
CKChang-Soo Kim
Chang-Soo Kim
WSWilliam Stoecker
William Stoecker
PNPaul Nam
Paul Nam
Optical oxygen sensors based on photoluminescence quenching have gained increasing attention as a superior method for continuous monitoring of oxygen in a growing number of applications. A simple and low-cost fabrication technique was developed to produce sensor arrays capable of two-dimensional oxygen tension measurement. Sensor patches were printed on polyvinylidene chloride film using an oxygen-sensitive ink cocktail, prepared by immobilizing Pt (II) meso-tetra(pentafluorophenyl)porphine (PtTFPP) in monodispersed polystyrene microparticles. The dispersion media of the ink cocktail, high molecular weight polyvinyl pyrrolidone suspended in 50% ethanol (v/v in water), allowed adhesion promotion and compatibility with most common polymeric substrates. Ink phosphorescence intensity was found to vary primarily with fluorophore concentration and to a lesser extent with polystyrene particle size. The sensor performance was investigated as a function of oxygen concentrations employing two different techniques: a multi-frequency phase fluorometer and smart phone-based image acquisition. The printed sensor patch showed fast and repetitive response over 0-21% oxygen concentrations with high linearity (with R 2 > 0.99) in a Stern-Volmer plot, and sensitivity of I 0 /I 21 > 1.55. The optical sensor response on a surface was investigated further using two-dimensional images which were captured and analyzed under different oxygen environment. Printed sensor patch along with imaging read-out technique make an ideal platform for early detection of surface wounds associated with tissue oxygen.

1 January 2017 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
AFAltamash Fakki
Altamash Fakki
SASalahaldein Ahmed
Salahaldein Ahmed
JPJongwon Park
Jongwon Park
CKChang-Soo Kim
Chang-Soo Kim
There is an ever increasing need for simple, low-cost instruments for ubiquitous medical and environmental measurements in conjunction with networks and Internet-of-things. This work demonstrates that the optical mouse, one of the most common optoelectronic computer peripherals, can be used for chemical quantification. Particularly, we explore the feasibility of using the preassembled optical platform of mouse for oxygen and pH quantification. The image sensor and the light-emitting diode (LED) serve as photodetector and excitation/illumination light source, respectively, while the preinstalled microoptics (e.g., lens and waveguide) provide a fixed optical arrangement convenient for sample analysis. This novel, cost-effective approach demonstrates the potential application of optical mouse for bioanalytical devices in conjunction with commercial sensor strips or simple microfluidic elements. This is one viable option for seamless integration of bioanalytical capability into existing personal computers and associate networks without significant additional hardware.

6 February 2023 in IEEE Sensors Letters
Verified
Journal Article
Closed access
DCDevdatt Chattopadhyay
Devdatt Chattopadhyay
JPJonghyun Park
Jonghyun Park
CKChang-Soo Kim
Chang-Soo Kim
A new class of potentially implantable solid-state sensors is demonstrated utilizing biodegradable glass as main structural material. The device behavior is manipulated via chemical decomposition, and then physically disintegrated in a controlled manner. It is based on the capacitive sensing mechanism, comprising an elastic insulator between two borate-rich glass substrates. This meso-scale pressure sensor is characterized over a range of pressure of up to 14 MPa in a phosphate buffer solution environment. The sensor exhibits good sensitivity and reversibility responding to compressive pressures and remains fully functional before a desired, sudden failure caused by dissolution. The operational lifetime can be modified by altering the chemical composition or thickness of the biodegradable glass component. The proposed device concept is a viable option toward various temporary implantable devices without needing an additional surgical procedure to remove them after their duty.