Yong Hyun Chung

Dr. Yong Hyun Chung


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2010 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
CBCheol-Ha Baek
Cheol-Ha Baek
SLSeung-Jae Lee
Seung-Jae Lee
YCYong Choi
Yong Choi
YCYong Hyun Chung
Yong Hyun Chung
The purpose of this study was to optimize a large-angle pinhole collimator using Monte Carlo simulation for nuclear survey imaging. Simulations using GATE (Geant4 Application for Tomographic Emission) were performed to model the pinhole gamma camera system. A gamma camera consists of a cone-shaped pinhole collimator with a tungsten aperture and a CsI(Tl) scintillation crystal 6.0 mm thick and 50.0 mm × 50.0 mm in area. The focal length and the acceptance angle of the pinhole collimator were set to 14.5 mm and 120°, respectively. The intrinsic spatial resolution and sensitivity were simulated by changing the pinhole diameter and channel height. The point source of Tc-99m was located 30.0 mm above the center of the pinhole, and the projection data was estimated for pinhole diameter values from 0.5 mm to 4.0 mm while the channel heights were fixed between knife-edge and 3.0 mm. The optimal ranges of channel height and pinhole diameter were determined through evaluation of the intrinsic resolution and sensitivity tradeoff curves. The simulation results allowed us to determine the optimal values of pinhole diameter and channel height to be 1.5 mm and 0.5 mm, respectively, to get intrinsic resolution below 2.0 mm FWHM with a reasonable sensitivity for the system configured in this study. The resolution and sensitivity were measured experimentally, and the simulated and measured data were in good agreement. The results demonstrated that the pinhole collimator designed in this study could be utilized to create a large-angle radiation monitoring system.

29 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
MBMin Kyu Baek
Min Kyu Baek
YCYoon Soo Chung
Yoon Soo Chung
SLSeongyeon Lee
Seongyeon Lee
IKInsoo Kang
Insoo Kang
Jae Joon AhnJae Joon Ahn
Jae Joon Ahn
YCYong Hyun Chung
Yong Hyun Chung
Nuclear power is a sustainable energy source, but radiation management is required for its safe use. Radiation-detection technology has been developed for the safe management of radioactive materials in nuclear facilities but its performance may vary depending on the size and complexity of the structure of nuclear facilities. In this study, a nuclear monitoring system using a multi-sensor network was designed to monitor radioactive materials in a large nuclear facility. Additionally, an artificial-intelligence-based localization algorithm was developed to accurately locate radioactive materials. The system parameters were optimized using the Geant4 Application for Tomographic emission (GATE) toolkit, and the localization algorithm was developed based on the performance evaluation of the Artificial Neural Network (ANN) and Decision Tree (D-Tree) models. In this article, we present the feasibility of the proposed monitoring system by converging the radiation detection system and artificial intelligence technology.

15 June 2009 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
SLSeung-Jae Lee
Seung-Jae Lee
CBCheol-Ha Baek
Cheol-Ha Baek
YCYong Hyun Chung
Yong Hyun Chung
YCYong Choi
Yong Choi
WLWonho Lee
Wonho Lee

1 August 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
CBCheol-Ha Baek
Cheol-Ha Baek
HKHyun-Il Kim
Hyun-Il Kim
JHJi Yeon Hwang
Ji Yeon Hwang
SASu Jung An
Su Jung An
KKKwang Hyun Kim
Kwang Hyun Kim
YCYong Hyun Chung
Yong Hyun Chung

1 January 2006
Verified
Conference Paper
Closed access
JCJennifer S. Cho
Jennifer S. Cho
NVNam T. Vu
Nam T. Vu
YCYong Hyun Chung
Yong Hyun Chung
ZYZeta T. Yu
Zeta T. Yu
RSRobert W. Silverman
Robert W. Silverman
ACArion F. Chatziioannou
Arion F. Chatziioannou
A new device is being developed that will allow imaging of the distribution of charged particles in microfluidic circuits, using a scintillator, a lens and a charge coupled device (CCD). Microfluidic chips are an emerging technology that will facilitate the study of molecular processes in pico-liter levels in a finely controlled manner. The ability to quantify low amounts of radioactivity in a microfluidic chip will provide researchers with a platform to investigate molecular processes in a controlled in-vitro environment. The new detector system consists of a plastic scintillator, a C-mount compact lens, and a Sony ICX285AL interline-transfer CCD cooled with a Peltier device. A microfluidic chip filled with fluoro-deoxy-glucose (FDG) solution was coupled to a plastic scintillator and the set up was placed inside a light-tight box for imaging. Preliminary studies were performed to test the feasibility of using the scintillator-based CCD detector system for this application. The CCD performance parameters were characterized by the photon transfer curve. The camera gain constant and read-out noise were measured to be 0.746 e-/ADU (analog-to-digital unit) and 8 e-, respectively. The dark current was also investigated with different temperatures and binning factors. The spatial resolution was measured and line pairs of FDG in a microfluidic chip were discernable down to a 0.5 mm separation. The system was able to quantify the activity level reliably down to 5 nCi/mm2.

1 January 2013 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
HKHyun-Il Kim
Hyun-Il Kim
CBCheol-Ha Baek
Cheol-Ha Baek
SASu Jung An
Su Jung An
SKSung-Woo Kwak
Sung-Woo Kwak
YCYong Hyun Chung
Yong Hyun Chung