The compound parabolic concentrator is a promising technology for efficient solar irradiation exploitation at low- and medium-temperature levels. This collector type can be used in a series of applications, such as solar cooling, desalination, and industrial process heat applications. This work presents a novel compound parabolic concentrator that presents satisfying efficiency and low cost due to the use of flat glazing and not an evacuated tube receiver. More specifically, the goal of the present investigation is based on the energy and exergy analysis of a compound parabolic collector with flat glazing, which has a concentration ratio of 2.81. The collector is examined thermally and exegetically, aiming to calculate the efficiency of different operating inlet temperatures. Moreover, the solar unit is studied by a developed computational fluid dynamics model in the SolidWorks Flow Simulation tool. Emphasis is given to the calculation of the convection losses of the receiver tube with the internal air inside the collector. The heat convection coefficient is calculated, and the distribution of the thermal losses, convection, and radiation is presented. Furthermore, the temperature levels of the absorber, the cover glass, and the top thermal loss coefficient are found. The thermal efficiency of the solar unit was 77.4% for inlet temperature at 10 °C and 32.6% for inlet temperature at 110 °C. It was calculated that the maximum exergetic performance of the solar unit is 10.19% for operation at 90 °C, while the thermal efficiency for this case is 41.57%. Additionally, the temperature distributions for different cases are included in the present work.
This study presents a combined thermal and optical, three-dimensional analysis of an asymmetric compound parabolic collector (ACPC) with an integrated hybrid photovoltaic/thermal (PV/T) receiver with the aim of establishing a sustainable approach in two ways: firstly, by determining the optimal tilt angle for operations, and secondly, by introducing an innovative simulation method which reduces computational cost while calculating thermal performance. Initially the Incident Angle Modifier () was calculated for a wide range of incident angles, and the ray-tracing results were verified using three different simulation tools (Tonatiuh, COMSOL, and SolidWorks) with mean deviations being lower than 4%. The optimal tilt angle of the collector was determined for seven months of the year by conducting a detailed ray-tracing analysis for the mean day of each month considering whole day operation. In the thermal analysis part, the authors introduced novel numerical modeling for numerical simulations. This modeling method, designed with sustainability in mind, enables lighter computational domains for the air gap while achieving accurate numerical results. The approach was established using two distinct simulation tools: COMSOL and SolidWorks. From the optical analysis, it was found that in all months examined there is a four-hour time range around solar noon in which the optimum tilt angle remains constant at a value of 30°. The numerical models constructed for the thermal analysis were verified with each other (6.15% mean deviation) and validated through experimental results taken from the literature regarding the examined collector (<6% mean deviation). In addition, the two simulation tools exhibited a deviation of around 6% between each other. Finally, the thermal performance of the collector was investigated for the mean day of September at solar noon by adopting the optimal tilt angle for that month according to the optical analysis, considering inlet temperatures from 20 °C up to 80 °C.
High-temperature heat pumps consist of a promising choice for substituting conventional boilers and producing hot water with temperature levels in the range of 70–80 °C. The use of high-temperature heat pumps makes it possible to exploit the existing radiators in existing buildings to achieve effective heating of the indoor space and keep thermal comfort at high standards. The goal of this work is the detailed investigation of a high-temperature heat pump, with the R1234ze(E) as the working medium for producing heating at 80 °C for space-heating purposes, in Greek climate conditions. The analysis was conducted at two locations, one in the south (Athens—Zone B) and one in the north (Thessaloniki—Zone C), in order to examine the performance of the study’s technology in the most representative locations of Greece. The thermodynamic analysis of the heat pump was performed with a developed model in Engineering Equation Solver by exploiting real data from the compressor manufacturer and by practically using a gray box model. The heating thermal loads were calculated with a dynamic analysis using TRNSYS software. According to the final results, the high-temperature heat pump was beneficial when compared to a conventional oil boiler from energy, financial, and environmental points of view. The net savings were found at EUR 6448 for Athens and EUR 13,161 for Thessaloniki; the simple payback period resulted in 8.03 years for Athens and 6.11 years for Thessaloniki, while the CO2 emissions avoidance was found at 35% for Athens and 32% for Thessaloniki. Last but not least, the lifetime CO2 emissions reduction was calculated at 20,882 kgCO2 for Athens and 35,278 kgCO2 for Thessaloniki.
The objective of this work is the integration of a linear cavity receiver in an asymmetric compound parabolic collector. Two different numerical models were developed; one for the conventional geometry and one for the cavity configuration. Both models were examined for inlet temperatures from 20 °C up to 80 °C, considering water as the operating fluid with a typical volume flow rate of 15 lt/h. Emphasis was given to the comparison of the thermal and optical performance between the designs, as well as in the temperature levels of the fluids and the receiver. The geometry of the integrated cavity receiver was optimized according to two independent parameters and two possible optimum designs were finally revealed. The optimization took place regarding the optical performance of the collector with the cavity receiver. The simulation results indicated that the cavity design leads to enhancements of up to 4.40% and 4.00% in the optical and thermal efficiency respectively, while the minimum possible enhancement was above 2.20%. The mean enhancements in optical and thermal performance were found to be 2.90% and 2.92% respectively. Moreover, an analytical solution was developed for verifying the numerical results and the maximum deviations were found to be less than 5% in all the compared parameters. Especially, in thermal efficiency verification, the maximum deviation took a value of less than 0.5%. The design and the simulations in the present study were conducted with the SolidWorks Flow Simulation tool.
Hydrogen has received increased attention in the last decades as a green energy carrier and a promising future fuel. The integration of hydrogen, as well as the development of cogeneration plants, makes the energy sector more eco-friendly, and sustainable. The aim of this paper is the investigation of a solar-fed cogeneration system that can produce power and compressed green hydrogen. The examined unit contains a parabolic trough collector solar field, a thermal energy storage tank, an organic Rankine cycle, and a proton exchange membrane water electrolyzer. The installation also includes a hydrogen storage tank and a hydrogen compressor. The unit is analyzed parametrically in terms of thermodynamic performance and economic viability in steady-state conditions with a developed and accurate model. Taking into account the final results, the overall energy efficiency is calculated at 14.03%, the exergy efficiency at 14.94%, and the hydrogen production rate at 0.205 kg/h. Finally, the payback period and the net present value are determined at 9 years and 122 k€, respectively.
A special kind of flat plate collectors was examined in detail through CFD analysis. The distinctiveness of the current model has to do with the piping system was applied which is a serpentine flow conduit. The operation of the collector was examined at four different inclination angles (0?, 15?, 30?, and 45?) and several values of the inlet water temperature (10-80?C per 10?C) by providing the same heat perpendicular to the cover in each case. The thermal efficiency as well as the temperature fields of the collector was determined first. Furthermore, the overall heat losses were calculated and compared to these arisen from the Cooper-Dunkle assumption while the mean divergence between these two solutions was around 5%. Moreover, the natural convection inside the gap as well as the tube to water convection was examined and the heat transfer coefficients were validated from theoretical models in horizontal position. In particular, the simulation results found to diverge from the theoretical ones about 12.5% and 7% as regards the pipe flow and the air-gap, respectively. In addition, a remarkable flow phenomenon was observed at the bends of the pipe and the nature of it was explained in detail. Last but not least, the inclination angle seems that affects significantly the collector?s performance since the higher the slope the lower the convection losses. Solidworks and its simulation program Flow Simulation were used to design and simulate the whole collector.