Bolin Pan

Dr. Bolin Pan

Biomedical Engineering, King's College London, London, City of London, UK

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2023 in British Journal of Radiology
Verified
Journal Article
Open access
ARAndrew J Reader
Andrew J Reader
BPBolin Pan
Bolin Pan
Image reconstruction for positron emission tomography (PET) has been developed over many decades, with advances coming from improved modelling of the data statistics and improved modelling of the imaging physics. However, high noise and limited spatial resolution have remained issues in PET imaging, and state-of-the-art PET reconstruction has started to exploit other medical imaging modalities (such as MRI) to assist in noise reduction and enhancement of PET’s spatial resolution. Nonetheless, there is an ongoing drive towards not only improving image quality, but also reducing the injected radiation dose and reducing scanning times. While the arrival of new PET scanners (such as total body PET) is helping, there is always a need to improve reconstructed image quality due to the time and count limited imaging conditions. Artificial intelligence (AI) methods are now at the frontier of research for PET image reconstruction. While AI can learn the imaging physics as well as the noise in the data (when given sufficient examples), one of the most common uses of AI arises from exploiting databases of high-quality reference examples, to provide advanced noise compensation and resolution recovery. There are three main AI reconstruction approaches: (i) direct data-driven AI methods which rely on supervised learning from reference data, (ii) iterative (unrolled) methods which combine our physics and statistical models with AI learning from data, and (iii) methods which exploit AI with our known models, but crucially can offer benefits even in the absence of any example training data whatsoever. This article reviews these methods, considering opportunities and challenges of AI for PET reconstruction.

23 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BPBolin Pan
Bolin Pan
PMPaul K. Marsden
Paul K. Marsden
ARAndrew J. Reader
Andrew J. Reader
Multiplexed positron emission tomography (PET) imaging provides perfectly registered simultaneous functional and molecular imaging of more than one biomarker. However, the separation of the multiplexed PET signals within a single PET scan is challenging due to the fact that all PET tracers emit positrons, which, after annihilating with a nearby electron, give rise to 511 keV photon pairs that are detected in coincidence. Compartment modelling can separate single-tracer PET signals from multiplexed signals based on the differences in bio-distribution kinetics and radioactive decay. However, the compartment-modelling-based method requires staggered injections and assumes that each tracer’s input function is known. In this paper, we propose a deep-learning-based method to simultaneously separate dual-tracer PET signals without explicitly knowing the input functions. We evaluate the proposed deep-learning-based separation method on dual-tracer [18F]FDG and [11C]MET PET simulations and compare its separation performance to that of the compartment-modelling-based method, assessing performance dependence on the time interval between tracer injections as well as on the amount of training data. It is shown that the proposed method implicitly denoises the separated images and offers reduced variance in the separated images compared to compartment modelling.

1 July 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
BPBolin Pan
Bolin Pan
PMPaul K. Marsden
Paul K. Marsden
ARAndrew J. Reader
Andrew J. Reader
Background: Multiplexed positron emission tomography (mPET) imaging can measure physiological and pathological information from different tracers simultaneously in a single scan. Separation of the multiplexed PET signals within a single PET scan is challenging due to the fact that each tracer gives rise to indistinguishable 511 keV photon pairs, and thus no unique energy information for differentiating the source of each photon pair. Methods: Recently, many applications of deep learning for mPET image separation have been concentrated on pure data-driven methods, e.g., training a neural network to separate mPET images into single-tracer dynamic/static images. These methods use over-parameterized networks with only a very weak inductive prior. In this work, we improve the inductive prior of the deep network by incorporating a general kinetic model based on spectral analysis. The model is incorporated, along with deep networks, into an unrolled image-space version of an iterative fully 4D PET reconstruction algorithm. Results: The performance of the proposed method was evaluated on a simulated brain image dataset for dual-tracer [ $$^{18}$$ 18 F]FDG+[ $$^{11}$$ 11 C]MET PET image separation. The results demonstrate that the proposed method can achieve separation performance comparable to that obtained with single-tracer imaging. In addition, the proposed method outperformed the model-based separation methods (the conventional voxel-wise multi-tracer compartment modeling method (v-MTCM) and the image-space dual-tracer version of the fully 4D PET image reconstruction algorithm (IS-F4D)), as well as a pure data-driven separation [using a convolutional encoder-decoder (CED)], with fewer training examples. Conclusions: This work proposes a kinetic model-informed unrolled deep learning method for mPET image separation. In simulation studies, the method proved able to outperform both the conventional v-MTCM method and a pure data-driven CED with less training data.

10 August 2021 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Closed access
BPBolin Pan
Bolin Pan
SASimon R. Arridge
Simon R. Arridge
FLFelix Lucka
Felix Lucka
Ben CoxBen Cox
Ben Cox
NHNam Huynh
Nam Huynh
MBMarta M. Betcke
Marta M. Betcke
Curvelet frame is of special significance for photoacoustic tomography (PAT) due to its sparsifying and microlocalisation properties. We derive a one-to-one map between wavefront directions in image and data spaces in PAT which suggests near equivalence between the recovery of the initial pressure and PAT data from compressed/subsampled measurements when assuming sparsity in Curvelet frame. As the latter is computationally more tractable, investigation to which extent this equivalence holds conducted in this paper is of immediate practical significance. To this end we formulate and compare DR, a two step approach based on the recovery of the complete volume of the photoacoustic data from the subsampled data followed by the acoustic inversion, and p 0 R , a one step approach where the photoacoustic image (the initial pressure, p 0 ) is directly recovered from the subsampled data. Effective representation of the photoacoustic data requires basis defined on the range of the photoacoustic forward operator. To this end we propose a novel wedge-restriction of Curvelet transform which enables us to construct such basis. Both recovery problems are formulated in a variational framework. As the Curvelet frame is heavily overdetermined, we use reweighted l 1 norm penalties to enhance the sparsity of the solution. The data reconstruction problem DR is a standard compressed sensing recovery problem, which we solve using an ADMM-type algorithm, SALSA. Subsequently, the initial pressure is recovered using time reversal as implemented in the k-Wave Toolbox. The p 0 reconstruction problem, p 0 R , aims to recover the photoacoustic image directly via FISTA, or ADMM when in addition including a non-negativity constraint. We compare and discuss the relative merits of the two approaches and illustrate them on 2D simulated and 3D real data in a fair and rigorous manner.

11 April 2024 in Frontiers in Nuclear Medicine
Verified
Journal Article
Open access
BPBolin Pan
Bolin Pan
PMPaul K. Marsden
Paul K. Marsden
ARAndrew J. Reader
Andrew J. Reader
Introduction: In multiplexed positron emission tomography (mPET) imaging, physiological and pathological information from different radiotracers can be observed simultaneously in a single dynamic PET scan. The separation of mPET signals within a single PET scan is challenging due to the fact that the PET scanner measures the sum of the PET signals of all the tracers. The conventional multi-tracer compartment modeling (MTCM) method requires staggered injections and assumes that the arterial input functions (AIFs) of each tracer are known.Methods: In this work, we propose a deep learning-based method to separate triple-tracer PET images without explicitly knowing the AIFs. A dynamic triple-tracer noisy MLEM reconstruction was used as the network input, and dynamic single-tracer noisy MLEM reconstructions were used as training labels.Results: A simulation study was performed to evaluate the performance of the proposed framework on triple-tracer ([F18]FDG+Rb82+[Tc99m]sestamibi) PET myocardial imaging. The results show that the proposed methodology substantially reduced the noise level compared to the results obtained from single-tracer imaging. Additionally, it achieved lower bias and standard deviation in the separated single-tracer images compared to the MTCM-based method at both the voxel and region of interest (ROI) levels.Discussion: As compared to MTCM separation, the proposed method uses spatiotemporal information for separation, which improves the separation performance at both the voxel and ROI levels. The simulation study also demonstrates the feasibility and potential of the proposed DL-based method for the application to pre-clinical and clinical studies.

31 January 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
BPBolin Pan
Bolin Pan
PMPaul K Marsden
Paul K Marsden
ARAndrew J Reader
Andrew J Reader
Multiplexed positron emission tomography (mPET) imaging allows simultaneous observation of physiological and pathological information from multiple tracers in a single PET scan. Although supervised deep learning has demonstrated superior performance in mPET image separation compared to purely model-based methods, acquiring large amounts of paired single-tracer data and multi-tracer data for training poses a practical challenge and needs extended scan durations for patients. In addition, the generalisation ability of the supervised learning framework is a concern, as the patient being scanned and their tracer kinetics may potentially fall outside the training distribution. In this work, we propose a self-supervised learning framework based on the deep image prior (DIP) for mPET image separation using just one dataset. In particular, we integrate the multi-tracer compartmental model into the DIP framework to estimate the parametric maps of each tracer from the measured dynamic dual-tracer activity images. Consequently, the separated dynamic single-tracer activity images can be recovered from the estimated tracer-specific parametric maps. In the proposed method, dynamic dual-tracer activity images are used as the training label, and the static dual-tracer image (reconstructed from the same patient data from the start to the end of acquisition) is used as the network input. The performance of the proposed method was evaluated on a simulated brain phantom for dynamic dual-tracer [18F]FDG+[11C]MET activity image separation and parametric map estimation. The results demonstrate that the proposed method outperforms the conventional voxel-wise multi-tracer compartmental modeling method (vMTCM) and the two-step method DIP-Dn+vMTCM (where dynamic dual-tracer activity images are first denoised using a U-net within the DIP framework, followed by vMTCM separation) in terms of lower bias and standard deviation in the separated single-tracer images and also for the estimated parametric maps for each tracer, at both voxel and ROI levels.