Mei Chen

Dr. Mei Chen

College of Environmental Science and Engineering, Nankai University, Tianjin 300350, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2023 in Chemical Engineering Journal
Verified
Journal Article
Closed access
Mei ChenMei Chen
Mei Chen
YLYanli Li
Yanli Li
XSXinyi Sun
Xinyi Sun
RDRuobin Dai
Ruobin Dai
JZJunjian Zheng
Junjian Zheng
ZWZhiwei Wang
Zhiwei Wang

6 August 2024 in Water Research
Verified
Journal Article
Closed access
XSXinyi Sun
Xinyi Sun
Mei ChenMei Chen
Mei Chen
YLYanli Li
Yanli Li
JWJinning Wang
Jinning Wang
MZMinliang Zhang
Minliang Zhang
XWXin Wang
Xin Wang

27 June 2023 in Water Research
Verified
Journal Article
Closed access
TWTuo Wang
Tuo Wang
Mei ChenMei Chen
Mei Chen
JZJiaxuan Zhu
Jiaxuan Zhu
NLNan Li
Nan Li
Xin WangXin Wang
Xin Wang

15 September 2023 in Chemical Engineering Journal
Verified
Journal Article
Closed access
YLYanli Li
Yanli Li
XWXunhao Wang
Xunhao Wang
ZLZhouyan Li
Zhouyan Li
Mei ChenMei Chen
Mei Chen
JZJunjian Zheng
Junjian Zheng
XWXin Wang
Xin Wang

27 December 2023 in Environmental Science and Ecotechnology
Verified
Journal Article
Open access
JWJinning Wang
Jinning Wang
Mei ChenMei Chen
Mei Chen
JZJiayao Zhang
Jiayao Zhang
XSXinyi Sun
Xinyi Sun
NLNan Li
Nan Li
Xin WangXin Wang
Xin Wang
Bioelectrochemical systems (BES) have emerged as a dual-function technology for treating wastewater and recovering energy. A vital element of BES is the rapid formation and maintenance of electroactive biofilms (EABs). Previous attempts to accelerate EAB formation and improve electroactivities focused on enhancing the bacterial adhesion process while neglecting the rate-limiting step of the bacterial transport process. Here, we introduce membrane filtration into BES, establishing a dynamic membrane filtration system that enhances overall performance. We observed that optimal membrane flux considerably reduced the startup time for EAB formation. Specifically, EABs established under a 25 L m-2 h-1 flux (EAB25 LMH) had a formation time of 43.8 ± 1.3 h, notably faster than the 51.4 ± 1.6 h in the static state (EAB0 LMH). Additionally, EAB25 LMH exhibited a significant increase in maximum current density, approximately 2.2 times higher than EAB0 LMH. Pearson correlation analysis indicated a positive relationship between current densities and biomass quantities and an inverse correlation with startup time. Microbial analysis revealed two critical findings: (i) variations in maximum current densities across different filtration conditions were associated with redox-active substances and biomass accumulation, and (ii) the incorporation of a filtration process in EAB formation enhanced the proportion of viable cells and encouraged a more diverse range of electroactive bacteria. Moreover, the novel electroactive membrane demonstrated sustained current production and effective solid-liquid separation during prolonged operation, indicating its potential as a viable alternative in membrane-based systems. This approach not only provides a new operational model for BES but also holds promise for expanding its application in future wastewater treatment solutions.

26 September 2024 in Chemical Engineering Journal
Verified
Journal Article
Closed access
YLYanli Li
Yanli Li
Mei ChenMei Chen
Mei Chen
XSXinyi Sun
Xinyi Sun
MZMinliang Zhang
Minliang Zhang
JWJinning Wang
Jinning Wang
XWXin Wang
Xin Wang