Kyung Sook Kim

Dr. Kyung Sook Kim


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
IKIn Soo Ko
In Soo Ko
HKHeung-Sik Kang
Heung-Sik Kang
HHHeo Hoon
Heo Hoon
CKChangbum Kim
Changbum Kim
GKGyujin Kim
Gyujin Kim
KLKi Bong Lee
Ki Bong Lee
The construction of Pohang Accelerator Laboratory X-ray Free-Electron Laser (PAL-XFEL), a 0.1-nm hard X-ray free-electron laser (FEL) facility based on a 10-GeV S-band linear accelerator (LINAC), is achieved in Pohang, Korea by the end of 2016. The construction of the 1.11 km-long building was completed by the end of 2014, and the installation of the 10-GeV LINAC and undulators started in January 2015. The installation of the 10-GeV LINAC, together with the undulators and beamlines, was completed by the end of 2015. The commissioning began in April 2016, and the first lasing of the hard X-ray FEL line was achieved on 14 June 2016. The progress of the PAL-XFEL construction and its commission are reported here.

30 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DSDaeho Sung
Daeho Sung
DNDaewoong Nam
Daewoong Nam
MKMyong-Jin Kim
Myong-Jin Kim
SKSeonghan Kim
Seonghan Kim
KKKyung Sook Kim
Kyung Sook Kim
SKSangsoo Kim
Sangsoo Kim
We developed a single-shot coherent X-ray imaging instrument at the hard X-ray beamline of the Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL). This experimental platform was established to conduct a variety of XFEL experiments, including coherent diffraction imaging (CDI), X-ray photon correlation spectroscopy (XPCS), and coherent X-ray scattering (CXS). Based on the forward-scattering geometry, this instrument utilizes a fixed-target method for sample delivery. It is well optimized for single-shot-based experiments in which one expects to observe the ultrafast phenomena of nanoparticles at picosecond temporal and nanometer spatial resolutions. In this paper, we introduce a single-shot coherent X-ray imaging instrument and report pump–probe coherent diffraction imaging (PPCDI) of Ag nanoparticles as an example of its applications.

1 January 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AMAlessandro Marras
Alessandro Marras
JMJonathan Correa Magdalena
Jonathan Correa Magdalena
SLSabine Lange
Sabine Lange
VVVahagn Vardanyan
Vahagn Vardanyan
TGTim Gerhardt
Tim Gerhardt
CWCornelia B. Wunderer
Cornelia B. Wunderer
In this paper the back-side-illuminated Percival 2-Megapixel (P2M) detector is presented, along with its characterization by means of optical and X-ray photons. For the first time, the response of the system to soft X-rays (250 eV to 1 keV) is presented. The main performance parameters of the first detector are measured, assessing the capabilities in terms of noise, dynamic range and single-photon discrimination capability. Present limitations and coming improvements are discussed.

1 July 2012 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
NDNguyen Van Do
Nguyen Van Do
PKPham Duc Khue
Pham Duc Khue
KTKim Tien Thanh
Kim Tien Thanh
GKGuinyun Kim
Guinyun Kim
MLMan-Woo Lee
Man-Woo Lee
WNWon Namkung
Won Namkung

22 September 2023 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
TCTae-Kyu Choi
Tae-Kyu Choi
JPJaeku Park
Jaeku Park
GKGyujin Kim
Gyujin Kim
HJHoyoung Jang
Hoyoung Jang
SPSang-Youn Park
Sang-Youn Park
SCSae Hwan Chun
Sae Hwan Chun
Self-seeded hard X-ray pulses at PAL-XFEL were used to commission a resonant X-ray emission spectroscopy experiment with a von Hamos spectrometer. The self-seeded beam, generated through forward Bragg diffraction of the [202] peak in a 100 µm-thick diamond crystal, exhibited an average bandwidth of 0.54 eV at 11.223 keV. A coordinated scanning scheme of electron bunch energy, diamond crystal angle and silicon monochromator allowed us to map the Ir Lβ2 X-ray emission lines of IrO2 powder across the Ir L 3-absorption edge, from 11.212 to 11.242 keV with an energy step of 0.3 eV. This work provides a reference for hard X-ray emission spectroscopy experiments utilizing self-seeded pulses with a narrow bandwidth, eventually applicable for pump–probe studies in solid-state and diluted systems.

31 October 2023 in IUCrJ
Verified
Journal Article
Open access
PDF file
IRIan Robinson
Ian Robinson
JGJack P. Griffiths
Jack P. Griffiths
RKRobert Koch
Robert Koch
TATadesse Abebaw Assefa
Tadesse Abebaw Assefa
ASAna F. Suzana
Ana F. Suzana
Emil BozinEmil Bozin
Emil Bozin
X-ray structural science is undergoing a revolution driven by the emergence of X-ray Free-electron Laser (XFEL) facilities. The structures of crystalline solids can now be studied on the picosecond time scale relevant to phonons, atomic vibrations which travel at acoustic velocities. In the work presented here, X-ray diffuse scattering is employed to characterize the time dependence of the liquid phase emerging from femtosecond laser-induced melting of polycrystalline gold thin films using an XFEL. In a previous analysis of Bragg peak profiles, we showed the supersonic disappearance of the solid phase and presented a model of pumped hot electrons carrying energy from the gold surface to scatter at internal grain boundaries. This generates melt fronts propagating relatively slowly into the crystal grains. By conversion of diffuse scattering to a partial X-ray pair distribution function, we demonstrate that it has the characteristic shape obtained by Fourier transformation of the measured F(Q). The diffuse signal fraction increases with a characteristic rise-time of 13 ps, roughly independent of the incident pump fluence and consequent final liquid fraction. This suggests the role of further melt-front nucleation processes beyond grain boundaries.