Snoring, a symptom which may indicate the presence of the obstructive sleep apnoea syndrome (OSA), is also common in the general population. Recent studies have suggested that the acoustic characteristics of snoring sound may differ between simple snorers and OSA patients. We have studied a small number of patients with simple snoring and OSA, analysing the acoustic characteristics of the snoring sound. Seventeen male patients, 10 with OSA (apnoea/hypopnoea index (AHI) 26.2 events x h(-1)) and seven simple snorers (AHI 3.8 events x h(-1)), were studied. Full night polysomnography was performed and the snoring sound power spectrum was analysed. Spectral analysis of snoring sound showed the existence of two different patterns. The first pattern was characterized by the presence of a fundamental frequency and several harmonics. The second pattern was characterized by a low frequency peak with the sound energy scattered on a narrower band of frequencies, but without clearly identified harmonics. The seven simple snorers and two of the 10 patients with OSA (AIH 13 and 14 events x h(-1), respectively) showed the first pattern. The rest of the OSA patients showed the second pattern. The peak frequency of snoring was significantly lower in OSA patients, with all but one OSA patient and only one simple snorer showing a peak frequency below 150 Hz. A significant negative correlation was found between AHI and peak and mean frequencies of the snoring power spectrum (p<0.0016 and p<0.0089, respectively). In conclusion, this study demonstrates significant differences in the sound power spectrum of snoring sound between subjects with simple snoring and obstructive sleep apnoea patients.
1 January 1992 in IEEE Transactions on Biomedical Engineering
Many bioelectric signals result from the electrical response of physiological systems to an impulse that can be internal (ECG signals) or external (evoked potentials). In this paper an adaptive impulse correlated filter (AICF) for event-related signals that are time-locked to a stimulus is presented. This filter estimates the deterministic component of the signal and removes the noise uncorrelated with the stimulus, even if this noise is colored, as in the case of evoked potentials. The filter needs two inputs: the signal (primary input) and an impulse correlated with the deterministic component (reference input). We use the LMS algorithm to adjust the weights in the adaptive process. First, we show that the AICF is equivalent to exponentially weighted averaging (EWA) when using the LMS algorithm. A quantitative analysis of the signal-to-noise ratio improvement, convergence, and misadjustment error is presented. A comparison of the AICF with ensemble averaging (EA) and moving window averaging (MWA) techniques is also presented. The adaptive filter is applied to real high-resolution ECG signals and time-varying somatosensory evoked potentials.
1 January 1996 in Medical & Biological Engineering & Computing
Accurate signal estimation by means of coherent averaging techniques needs temporal alignment methods. A known low-pass filtering effect is yielded when alignment errors are present. This is very critical in the estimation of low-level high-frequency potentials in high-resolution ECG analysis. A comparative study of the performance of three alignment methods (the double-level method, a new time-delay estimation method based on normalized integrals, and matched filtering) is presented in this paper. A real signal and additive random noise for several signal-to-noise ratios (SNR's) are selected to make an ensemble of computer-simulated beats. The relation between the standard deviation of temporal misalignment versus SNR is discussed. A second study with real ECG signals is also presented. Several morphologies of QRS and P waves are tested. The results are in agreement with the computer simulation study. Nevertheless, the power spectrum of the noise process can affect the results. Matched filter estimation has been tested in the presence of power line interference (50 Hz), with poor results. An application of the three alignment methods as a function of the SNR is proposed. The new time-delay estimation method has been observed to be robust, even in the presence of nonwhite noise.