Ultrapermeable membranes (UPMs) have the potential of improving water production efficiency. However, operating at high water fluxes will intensify concentration polarization and membrane fouling. Inspired by the V-formation of birds in nature we propose a transformative membrane module that enables a doubled mass transfer coefficient with a moderately increased friction loss coefficient. Moreover, we present a practical technological pathway for the UPM systems to achieve 338% improvement of average water flux and 18% energy savings relative to state-of-the-art seawater desalination plants. The work makes it practical to operate at a high average water flux of 84 L m−2 h−1 with a controlled concentration polarization for the UPM systems. It breaks through the module development bottlenecks for the next-generation UPM systems and has enormous potential application for alleviating water scarcity crisis in the coming decades.
Directly solving sophisticated partial differential equation constrained optimization problems is not only extremely time-consuming, but also very hard to find unique optimal solutions. Here, we propose stable and efficient surrogate models for seawater reverse osmosis desalination processes that enable thorough quantitative description of hydrodynamics and local transport characteristics in narrow flow channels. Without iteratively solving complex multi-physics simulation problem taking several hours, the proposed multi-scale design optimization framework significantly reduces the problem complexity by computing the surrogate models in seconds. Moreover, a fast-converging active subspace particle swarm optimization framework is proposed to address the optimal design problem. Compared to the standard particle swarm optimization algorithm, the proposed method enhances the average optimum by 14% and the standard deviation of optimum results for multiple runs is reduced by no less than ten times. The optimized desalination system achieves 9% reduction on energy consumption and 30% improvement on water production efficiency.
In recent years, high permeability membranes (HPMs) have attracted wide attention in seawater reverse osmosis (SWRO) desalination. However, the limitation of hydrodynamics and mass transfer characteristics for conventional spiral wound modules defeats the advantage of HPMs. Feed spacer design is one of the effective ways to improve module performance by enhancing permeation flux and mitigating membrane fouling. Herein, we propose a multiscale modeling framework that integrates a three-dimensional multi-physics model with a permeable wall and an impermeable wall, respectively, at a sub-millimeter scale and a system-level model at a meter scale. Using the proposed solution framework, a thorough quantitative analysis at different scales is conducted and it indicates that the average errors of the friction coefficient and the Sherwood number using the impermeable wall model are less than 2% and 9%, respectively, for commercial SWRO membrane (water permeability 1 L m−2 h−1 bar−1) and HPMs (3 L m−2 h−1 bar−1, 5 L m−2 h−1 bar−1 and 10 L m−2 h−1 bar−1) systems, compared to the predictions using the permeable wall model. Using both the permeable and impermeable wall models, the system-level simulations, e.g., specific energy consumption, average permeation flux, and the maximum concentration polarization factor at the system inlet are basically the same (error < 2%), while the impermeable wall model has a significant advantage in computational efficiency. The multiscale framework coupling the impermeable wall model can be used to guide the efficient and accurate optimal spacer design and system design for HPMs using, e.g., a machine learning approach.
The development of advanced feed spacers under different working conditions can enhance the performance of the reverse osmosis (RO) desalination process. The 3D-printed experimental results on triply periodic minimal surfaces (TPMS)-based spacers in previous literature indicate that the spacers have higher permeation flux of water compared to those of the common commercial spacers. In this paper, a hybrid modeling approach is developed and applied to predict and evaluate the performance of TPMS-based spacers. The effect of feed channels’ height and porosity on the performance of spacers in brackish water RO (BWRO) process is studied by using a high-throughput approach. The predicted pressure drop by new simulations using the TPMS-based spacers (≈0.09–0.27 bar) from inlet to outlet in a typical two-stage BWRO system is reduced by more than 89% than that of using the commercial spacer (≈2.57 bar). Using the designed advanced spacers, the average permeation flux of water increases more than 8.6% compared to that of the commercial one. With the increase in feed channel height and porosity, the performance of spacers is gradually improved. TPMS-based spacers have significant industrial application prospects.
31 December 2024 in International Journal of Heat and Mass Transfer