Mauricio B C Salles

Prof. Mauricio B C Salles

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2011 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
CRC. Rahmann
C. Rahmann
HHH.-J. Haubrich
H.-J. Haubrich
AMA. Moser
A. Moser
RPRodrigo Palma
Rodrigo Palma
LVL. Vargas
L. Vargas
MSMauricio B C Salles
Mauricio B C Salles
In this paper, a novel adaptive strategy to obtain technically justified fault-ride-through requirements for wind turbines (WTs) is proposed. The main objective is to promote an effective integration of wind turbines into power systems with still low penetration levels of wind power based on technical and economical considerations. The level of requirement imposed by the strategy is increased stepwise over time, depending on system characteristics and on wind power penetration level. The idea behind is to introduce stringent requirements only when they are technically needed for a reliable and secure power system operation. Voltage stability support and fault-ride-through requirements are considered in the strategy. Simulations are based on the Chilean transmission network, a midsize isolated power system with still low penetration levels of wind power. Simulations include fixed speed induction generators and doubly fed induction generators. The effects on power system stability of the wind power injections, integrated into the network by adopting the adaptive strategy, are compared with the effects that have the same installed capacity of wind power but only considering WTs able to fulfill stringent requirements (fault-ride-through capability and support voltage stability). Based on simulations and international experience, technically justified requirements for the Chilean case are proposed.

27 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
MSMauricio B C Salles
Mauricio B C Salles
JHJunling Huang
Junling Huang
MAMichael J. Aziz
Michael J. Aziz
WHWilliam W. Hogan
William W. Hogan
The volatility of electricity prices is attracting interest in the opportunity of providing net revenue by energy arbitrage. We analyzed the potential revenue of a generic Energy Storage System (ESS) in 7395 different locations within the electricity markets of Pennsylvania-New Jersey-Maryland interconnection (PJM), the largest U.S. regional transmission organization, using hourly locational marginal prices over the seven-year period 2008–2014. Assuming a price-taking ESS with perfect foresight in the real-time market, we optimized the charge-discharge profile to determine the maximum potential revenue for a 1 MW system as a function of energy/power ratio, or rated discharge duration, from 1 to 14 h, including a limited analysis of sensitivity to round-trip efficiency. We determined minimum potential revenue with a similar analysis of the day-ahead market. We presented the distribution over the set of nodes and years of price, price volatility, and maximum potential arbitrage revenue. From these results, we determined the breakeven overnight installed cost of an ESS below which arbitrage would be profitable, its dependence on rated discharge duration, its distribution over grid nodes, and its variation over the years. We showed that dispatch into real-time markets based on day-ahead market settlement prices is a simple, feasible method that raises the lower bound on the achievable arbitrage revenue.

12 April 2010 in Energies
Verified
Journal Article
Open access
PDF file
MSMauricio B C Salles
Mauricio B C Salles
KHKay Hameyer
Kay Hameyer
Jose Roberto CardosoJose Roberto Cardoso
Jose Roberto Cardoso
AGAhda. P. Grilo
Ahda. P. Grilo
CRClaudia Rahmann
Claudia Rahmann
In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT). According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.

18 November 2020 in IEEE Access
Verified
Journal Article
Open access
Seyed Iman TaheriSeyed Iman Taheri
Seyed Iman Taheri
MSMauricio B C Salles
Mauricio B C Salles
ECEduardo Marques da Costa
Eduardo Marques da Costa
Virtual power plant (VPP) interconnects distributed generation (DG) units, microgrids, and energy storage systems (ESSs) of an electrical power system. This paper presents a linear programming cost minimization model of VPP for the design and commitments of DG, ESS, and microgrid. Using a set of renewable energy resources, the proposed model creates a reliable, cost-effective, and environmentally friendly distribution system. Accurately, it illustrates the schedule of the VPP to operate autonomously. The proposed model is applied to a set of United States commercial load profiles to determine the investment benefit of implementing DGs in the power system. Analysis of results concerning variation in energy price illustrates feasible solutions. VPP decision-makers can select the best reasonable solution based on their specific project budget for feature electricity generation. Moreover, results show the need for the proposed method in VPP decision making.

18 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
LGLuis Alejandro Gutierrez Gomez
Luis Alejandro Gutierrez Gomez
AGAhda P. Grilo
Ahda P. Grilo
MSMauricio B C Salles
Mauricio B C Salles
Alfeu J. Sguarezi FilhoAlfeu J. Sguarezi Filho
Alfeu J. Sguarezi Filho
This paper presents a novel methodology for frequency control of a microgrid through doubly fed induction generator (DFIG) employing battery energy storage system (BESS) and droop control. The proposed microgrid frequency control is the result of the active power injection from the droop control implemented in the grid side converter (GSC) of the DFIG, and the BESS implemented in the DC link of the back-to-back converter also in the DFIG. This methodology guarantees the battery system charge during operation of the connected DFIG in the network, and the frequency control in microgrid operation after an intentional disturbance. In order for the DFIG to provide frequency support to the microgrid, the best-performing droop gain value is selected. Afterwards its performance is evaluated individually and together with the power injected by the battery. The power used for both battery charging and frequency support is managed and processed by the GSC without affecting the normal operation of the wind system. The simulation tests are performed using Matlab/Simulink toolbox.

24 January 2019 in Energies
Verified
Journal Article
Open access
PDF file
CPCesar O. Peralta P.
Cesar O. Peralta P.
GVGiovani Giulio Vieira
Giovani Giulio Vieira
SMSimon Meunier
Simon Meunier
RVRodrigo Vale
Rodrigo Vale
MSMauricio B C Salles
Mauricio B C Salles
Bruno Souza CarmoBruno Souza Carmo
Bruno Souza Carmo
Greenhouse gas emissions are one of the most critical worldwide concerns, and multiple efforts are being proposed to reduce these emissions. Shipping represents around 2% of global CO 2 emissions. Since ship power systems have a high dependence on fossil fuels, hybrid systems using diesel generators and batteries are becoming an interesting solution to reduce CO 2 emissions. In this article, we analyze the potential implementation of Li-ion batteries in a platform supply vessel system through simulations using HOMER software (Hybrid Optimization Model for Multiple Energy Resources). We evaluate the impact of battery characteristics such as round trip efficiency, rated power, and energy capacity. We also evaluate the potential CO 2 emissions reduction that could be achieved with two of the most common types of Li-ion batteries (lithium titanate, lithium iron phosphate). Furthermore, we consider that the Li-ion batteries are installed in a 20 ft container. Results indicate that the lithium iron phosphate battery has a better performance, even though the difference between both technologies is lower than 1% of total emissions. We also analyze the potential emissions reduction for different parts of a mission to an offshore platform for different configurations of the ship power system. The most significant potential CO 2 emissions reduction among the analyzed cases is 8.7% of the total emissions, and it is achieved by the configuration including the main and auxiliary diesel engines as well as batteries. Finally, we present managerial implications of these results for both companies operating ships and ship building companies.