Francesca Frijia

Dr. Francesca Frijia

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Antonella MeloniAntonella Meloni
Antonella Meloni
FFFrancesca Frijia
Francesca Frijia
DPDaniele Panetta
Daniele Panetta
GDGiulia Degiorgi
Giulia Degiorgi
CGCarmelo De Gori
Carmelo De Gori
Filippo CademartiriFilippo Cademartiri
Filippo Cademartiri
Photon-counting computed tomography (PCCT) is a new advanced imaging technique that is going to transform the standard clinical use of computed tomography (CT) imaging. Photon-counting detectors resolve the number of photons and the incident X-ray energy spectrum into multiple energy bins. Compared with conventional CT technology, PCCT offers the advantages of improved spatial and contrast resolution, reduction of image noise and artifacts, reduced radiation exposure, and multi-energy/multi-parametric imaging based on the atomic properties of tissues, with the consequent possibility to use different contrast agents and improve quantitative imaging. This narrative review first briefly describes the technical principles and the benefits of photon-counting CT and then provides a synthetic outline of the current literature on its use for vascular imaging.

7 February 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
LSLudovica Simonini
Ludovica Simonini
FFFrancesca Frijia
Francesca Frijia
LALamia Ait-Ali
Lamia Ait-Ali
IFIlenia Foffa
Ilenia Foffa
CVCecilia Vecoli
Cecilia Vecoli
FLFrancesco Lombardo
Francesco Lombardo
Olfactory dysfunction (OD) is one of the most common symptoms in COVID-19 patients and can impact patients’ lives significantly. The aim of this review was to investigate the multifaceted impact of COVID-19 on the olfactory system and to provide an overview of magnetic resonance (MRI) findings and neurocognitive disorders in patients with COVID-19-related OD. Extensive searches were conducted across PubMed, Scopus, and Google Scholar until 5 December 2023. The included articles were 12 observational studies and 1 case report that assess structural changes in olfactory structures, highlighted through MRI, and 10 studies correlating the loss of smell with neurocognitive disorders or mood disorders in COVID-19 patients. MRI findings consistently indicate volumetric abnormalities, altered signal intensity of olfactory bulbs (OBs), and anomalies in the olfactory cortex among COVID-19 patients with persistent OD. The correlation between OD and neurocognitive deficits reveals associations with cognitive impairment, memory deficits, and persistent depressive symptoms. Treatment approaches, including olfactory training and pharmacological interventions, are discussed, emphasizing the need for sustained therapeutic interventions. This review points out several limitations in the current literature while exploring the intricate effects of COVID-19 on OD and its connection to cognitive deficits and mood disorders. The lack of objective olfactory measurements in some studies and potential validity issues in self-reports emphasize the need for cautious interpretation. Our research highlights the critical need for extensive studies with larger samples, proper controls, and objective measurements to deepen our understanding of COVID-19’s long-term effects on neurological and olfactory dysfunctions.

19 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
GGGiulio Giovannetti
Giulio Giovannetti
NFNunzia Fontana
Nunzia Fontana
AFAlessandra Flori
Alessandra Flori
Maria Filomena SantarelliMaria Filomena Santarelli
Maria Filomena Santarelli
MTMauro Tucci
Mauro Tucci
FFFrancesca Frijia
Francesca Frijia
Radiofrequency (RF) coils for magnetic resonance imaging (MRI) applications serve to generate RF fields to excite the nuclei in the sample (transmit coil) and to pick up the RF signals emitted by the nuclei (receive coil). For the purpose of optimizing the image quality, the performance of RF coils has to be maximized. In particular, the transmit coil has to provide a homogeneous RF magnetic field, while the receive coil has to provide the highest signal-to-noise ratio (SNR). Thus, particular attention must be paid to the coil simulation and design phases, which can be performed with different computer simulation techniques. Being largely used in many sectors of engineering and sciences, machine learning (ML) is a promising method among the different emerging strategies for coil simulation and design. Starting from the applications of ML algorithms in MRI and a short description of the RF coil’s performance parameters, this narrative review describes the applications of such techniques for the simulation and design of RF coils for MRI, by including deep learning (DL) and ML-based algorithms for solving electromagnetic problems.

19 December 2022 in Electronics
Verified
Journal Article
Open access
PDF file
GGGiulio Giovannetti
Giulio Giovannetti
FFFrancesca Frijia
Francesca Frijia
AFAlessandra Flori
Alessandra Flori
Low-field magnetic resonance imaging (MRI) has become increasingly popular due to cost reduction, artifact minimization, use for interventional radiology, and a better safety profile. The different applications of low-field systems are particularly wide (muscle–skeletal, cardiac, neuro, small animals, food science, as a hybrid scanner for hyperthermia, in interventional radiology and in radiotherapy). The low-field scanners produce lower signal-to-noise ratio (SNR) images with respect to medium- and high-field scanners. Thus, particular attention must be paid in the minimization of the radiofrequency (RF) coil losses compared to the sample noise. Following a short description of the coil design and simulation methods (magnetostatic and full-wave), in this paper we will describe how the choice of electrical parameters (such as conductor geometry and capacitor quality) affects the coil’s overall performance in terms of the quality factor Q, ratio between unloaded and loaded Q, and coil sensitivity. Subsequently, we will summarize the work carried out at our electromagnetic laboratory in collaboration with MR-manufacturing companies in the field of RF coil design, building, and testing for 0.18–0.55 T magnetic resonance (MR) clinical scanners by classifying them between surface-, volume-, and phased-array coils.

26 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
GGGiulio Giovannetti
Giulio Giovannetti
AFAlessandra Flori
Alessandra Flori
NMNicola Martini
Nicola Martini
RFRoberto Francischello
Roberto Francischello
GAGiovanni Donato Aquaro
Giovanni Donato Aquaro
FFFrancesca Frijia
Francesca Frijia
Sodium (23Na) is the most abundant cation present in the human body and is involved in a large number of vital body functions. In the last few years, the interest in Sodium Magnetic Resonance Imaging (23Na MRI) has considerably increased for its relevance in physiological and physiopathological aspects. Indeed, sodium MRI offers the possibility to extend the anatomical imaging information by providing additional and complementary information on physiology and cellular metabolism with the heteronuclear Magnetic Resonance Spectroscopy (MRS). Constraints are the rapidly decaying of sodium signal, the sensitivity lack due to the low sodium concentration versus 1H-MRI induce scan times not clinically acceptable and it also constitutes a challenge for sodium MRI. With the available magnetic fields for clinical MRI scanners (1.5 T, 3 T, 7 T), and the hardware capabilities such as strong gradient strengths with high slew rates and new dedicated radiofrequency (RF) sodium coils, it is possible to reach reasonable measurement times (~10–15 min) with a resolution of a few millimeters, where it has already been applied in vivo in many human organs such as the brain, cartilage, kidneys, heart, as well as in muscle and the breast. In this work, we review the different geometries and setup of sodium coils described in the available literature for different in vivo applications in human organs with clinical MR scanners, by providing details of the design, modeling and construction of the coils.

17 May 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
FFFrancesca Frijia
Francesca Frijia
AFAlessandra Flori
Alessandra Flori
GGGiulio Giovannetti
Giulio Giovannetti
Andrea BarisonAndrea Barison
Andrea Barison
Luca MenichettiLuca Menichetti
Luca Menichetti
Vincenzo PositanoVincenzo Positano
Vincenzo Positano
Cardiovascular disease shows, or may even be caused by, changes in metabolism. Hyperpolarized magnetic resonance spectroscopy and imaging is a technique that could assess the role of different aspects of metabolism in heart disease, allowing real-time metabolic flux assessment in vivo. In this review, we introduce the main hyperpolarization techniques. Then, we summarize the use of dedicated radiofrequency 13C coils, and report a state of the art of 13C data acquisition. Finally, this review provides an overview of the pre-clinical and clinical studies on cardiac metabolism in the healthy and diseased heart. We furthermore show what advances have been made to translate this technique into the clinic in the near future and what technical challenges still remain, such as exploring other metabolic substrates.