Giant cell tumor of bone (GCTB) is an aggressive non-cancerous bone tumor associated with risks of sarcoma and metastasis. Once malignancy occurs, the prognosis is generally poor. Surgery remains the main treatment for GCTB. Multidisciplinary management is a feasible option for patients wherein surgical resection is not an option or for those with serious surgery-related complications. Denosumab is an anti-nuclear factor kappa B ligand approved for the treatment of postmenopausal women with osteoporosis, bone metastases, and advanced or inoperable GCTB. However, the guidelines for treating GCTB are unclear; its short-term efficacy and safety in inoperable patients have been demonstrated. Lengthier therapies (high cumulative doses) or pre-operative adjuvant therapy may be associated with severe complications and high local recurrence rates. Short-term administration helps attain satisfactory local control and functionality. As a result, lately, the impact of different doses and lengths of treatment on the efficacy of denosumab in GCTB treatment, the incidence of complications, and recurrence rates have gained attention. The efficacy and safety of denosumab against GCTB, its impact on imaging assessment, related complications, and recurrence of GCTB were previously reviewed. For further research direction, this paper reviews the progress of studies evaluating the impact of the dose and duration of denosumab therapy for GCTB.
27 April 2023 in Clinical and Experimental Medicine
Maintaining effective reduction and firm fixation in inferior pole patellar fractures is a highly challenging task. There are various treatment methods available; although tension-band wiring combined with cerclage wiring (TBWC) is the mainstream approach, its effectiveness is limited. Herein, we propose and evaluate a new technique called candy box (CB), based on separate vertical wiring (SVW), for the treatment of inferior pole patellar fractures. Specifically, we provide biomechanical evidence for its clinical application. Five fixation models were built: SVW combined with cerclage wiring (SVWC); TBWC; modified SVW with the middle (MSVW-A) or upper (MSVW-B) 1/3 of the steel wire reserved, and CB. A finite element analysis was performed to compare the displacement and stress under 100-N, 200-N, 300-N, 400-N and 500-N force loads. Three-dimensional printing technology was utilized to create fracture models, and the average displacement of each model group was compared under a 500-N force. The results of the finite element analysis indicate that CB technology exhibits significantly lower maximum displacement, bone stress, and wire stress compared to that with other technologies under different loads. Additionally, in biomechanical experiments, the average force displacement in the CB group was significantly smaller than that with other methods under a 500-N force (P < 0.05). CB technology has the potential to overcome the limitations of current techniques due to its superior biomechanical characteristics. By incorporating early functional exercise and ensuring strong internal fixation, patient prognosis could be enhanced. However, further clinical trials are needed to fully evaluate the therapeutic effects of CB technology.
23 January 2025 in Journal of the Mechanical Behavior of Biomedical Materials
Aims: Our study explores the candy box (CB) technique with sutures and Nice knot as a novel treatment for inferior pole patellar fractures, potentially superior to traditional wire fixation.Methods: CT data from five adult knee joints were extracted to create finite element models for inferior pole patellar fractures and four internal fixation models. These included CB technique combined with high-strength sutures and Nice knot (CB-H), CB technique combined with tendon sutures and Nice knot (CB-T), CB technique combined with steel wires (CB-S), and tension-band wiring combined with cerclage wiring (TBWC). Displacement and stress distribution during knee flexion and extension were compared. Physical models were created using 3D printing technology. These models were then subjected to static tensile test and dynamic fatigue test. Data from 21 patients treated with CB-H and 22 patients treated with TBWC were analyzed to assess the effectiveness.Results: Finite element analysis (FEA) indicated that displacements for CB-H and CB-T were below the failure threshold in all knee joint states. Stresses on the patella and internal fixation were lower in the CB-H and CB-T groups compared with the CB-S and TBWC groups. Both static and dynamic biomechanical experiments confirmed that displacements of CB-H and CB-T also remained below the failure threshold. In clinical research, the CB-H group outperformed the TBWC group in operating time, intraoperative blood loss, length of incision and time to clinical union, and complication control.Conclusion: The CB technique combined with sutures and Nice knot can provide sufficient fixation strength for inferior pole patellar fractures. This method enables early functional exercise and avoids the need for secondary surgery. It could be a promising alternative to traditional TBWC surgery.Cite this article: Bone Joint Res 2025;14(8):721–734.
24 April 2024 in Frontiers in Bioengineering and Biotechnology
The separate vertical wire (SVW) technique and the improved candy box (CB) technique have been proposed for treating inferior pole patellar fractures. However, there is still a lack of clear explanation regarding the location of the wire passing through the patella. Five models of SVW techniques were established in different positions. Finite element analysis was then conducted to determine the optimal bone tunnel position for the SVW technique. Based on these findings, six groups of finite element models were created for CB techniques. The maximum displacement and stress on both the patella and steel wire were compared among these groups under 100-N, 200-N, 300-N, 400-N, and 500-N force loads. The results indicated that, in the SVW technique, the steel wire group near the fracture end of the longitudinal bone tunnel showed minimal displacement and stress on the patella when subjected to different forces. On the other hand, in the CB technique, both the patella and wire experienced minimal stress when a transverse bone tunnel wire was placed near the upper posterior aspect of patella. In conclusion, the SVW technique may require the bone tunnel wire to be positioned near the fractured end of the lower pole of the patella. On the other hand, in CB technique, the transverse bone tunnel wire passing through the patella may be close to its upper posterior aspect. However, further validation is necessary through comprehensive finite element analysis and additional biomechanical experiments.