Timur Lesbekov

Dr. Timur Lesbekov

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
RKRymbay Kaliyev
Rymbay Kaliyev
TLTimur Lesbekov
Timur Lesbekov
SBSerik Bekbossynov
Serik Bekbossynov
ZNZhuldyz Nurmykhametova
Zhuldyz Nurmykhametova
MBMakhabbat Bekbossynova
Makhabbat Bekbossynova
YPYuriy Pya
Yuriy Pya
Background: Organ Care System (OCS) minimizes the cold ischemic time and allows for optimization of logistics and meticulous recipient preparation. Impact of normothermic ex-vivo preservation using OCS compared with cold storage (CS) for prolonged heart preservation especially beneficial for high-risk recipients bridged to transplantation with Mechanical Circulatory Support (MCS). Methods: Between 2012 and 2018, we performed a retrospective single-center review of prospectively collected data. All patients who underwent heart transplantation with MCS using the OCS Heart (n = 25) versus standard cold storage (n = 10) were included in this study. Results: During this period, 353 patients were implanted with left ventricular assisted device (LVAD) and 35 (10%) were bridged to heart transplantation. There was no significant difference in donor and recipient characteristics and risk factors. The Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was a trend towards higher estimated risk of death at 1y in the OCS group (14.2 vs. 10.8% p = 0.083). Mean total ischemic time during preservation was statistically significantly longer in CS vs OCS group (210 (23) Vs 74.6 (13) min p = 0.001). Median ex vivo normothermic heart perfusion time in OCS was 348.4(132; 955) min. There was significant difference in total out of body time between OCS group 423(67) Vs CS group 210(23) min p = 0.002). All patients were alive on the 30th days post implant in CS groups and 96% in OCS group (p = 0.5). Conclusion: Normothermic ex-vivo preservation of the allograft during transportation with the organ care system might be beneficial for long-time out of body organ preservation in comparison of cold storage especially for recipients on mechanical circulatory support.

20 January 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TLTimur Lesbekov
Timur Lesbekov
AMAbdurashid Mussayev
Abdurashid Mussayev
ASAliya Sailybayeva
Aliya Sailybayeva
RKRymbay Kaliyev
Rymbay Kaliyev
AKAidyn Kuanyshbek
Aidyn Kuanyshbek
SKSadyk Khamitov
Sadyk Khamitov
Introduction: TAVR remains a complex procedure that may result in serious intraprocedural complications. In many of these circumstances, venoarterial extracorporeal membrane oxygenation (V-A ECMO) helps to manage complications, provides a hemodynamic back-up, and bridges to an emergency open heart surgery. The clinical outcomes of 27 patients who underwent prophylactic implantation of peripheral V-A ECMO (pV-A ECMO) during high-risk transcatheter aortic valve replacement (TAVR) cases are described. Methods: From June 2012 to October 2022, 590 consecutive patients underwent TAVR at our center. Of these, 27 patients (4.5%) underwent TAVR with pV-AECMO because they were deemed very high risk for periprocedural complications and formed the study population. Results: There were no pV-A ECMO, hemodynamic or TAVR implantation complications. Decannulation of the ECMO system was performed in 92.6% of cases at the end of the procedure in the hybrid-operating theatre. The mean duration of pV-A ECMO for procedure support was 51.4 ± 10.3 min. There were no ECMO-related vascular or bleeding complications. Conclusion: This study shows that the prophylactic placement of awake peripheral V-A ECMO provides excellent temporary cardio-circulatory and pulmonary support during very high-risk TAVR procedures.

1 January 2020 in Clinical and Experimental Surgery. Petrovsky journal
Verified
Journal Article
Closed access
YPYu.V. Pya
Yu.V. Pya
RKR. Kaliyev
R. Kaliyev
ASAliya Sailybayeva
Aliya Sailybayeva
TLTimur Lesbekov
Timur Lesbekov
SBS.T. Bekbossynov
S.T. Bekbossynov
GTG.M. Turganbayeva
G.M. Turganbayeva

17 September 2025 in JACC: Case Reports
Verified
Journal Article
Open access
AMAbdurashid Mussayev
Abdurashid Mussayev
PFPhillip Freeman
Phillip Freeman
YRYerkezhan Raissov
Yerkezhan Raissov
YOYerik Otarbayev
Yerik Otarbayev
LALyazzat Abikeyeva
Lyazzat Abikeyeva
YPYuriy Pya
Yuriy Pya
The LAMPOON (laceration of the anterior mitral leaflet to prevent outflow obstruction) procedure is an innovative transcatheter technique designed to prevent left ventricular outflow tract obstruction during transcatheter mitral valve interventions. A 14-year-old male patient with a history of infective endocarditis, previously treated with surgical aortic valve replacement and mitral annuloplasty, presented with severe mitral regurgitation and decompensated heart failure. Owing to prohibitive surgical risk, a transcatheter mitral valve-in-ring replacement (TMViR) was performed with adjunctive LAMPOON to prevent left ventricular outflow tract obstruction. This is to our knowledge the first reported pediatric case of TMViR facilitated by LAMPOON. The procedure was technically successful, and the patient recovered without major complications. This case highlights a novel application of LAMPOON in the pediatric population. Given the absence of surgical options, this approach offers a life-saving, minimally invasive alternative and expands the role of structural interventions in children with complex valvular disease. LAMPOON can enable safe TMViR in high-risk pediatric patients. Successful outcomes require careful planning, imaging, and multidisciplinary coordination.

1 January 2023 in Clinical and Experimental Surgery. Petrovsky journal
Verified
Journal Article
Open access
AKA.S. Kuanyshbek
A.S. Kuanyshbek
TLTimur Lesbekov
Timur Lesbekov
BBB.E. Bekishev
B.E. Bekishev
RKR.B. Kaliev
R.B. Kaliev
NJN.A. Jabayeva
N.A. Jabayeva
LFL.R. Faizov
L.R. Faizov
Гемадсорбция для инфекционного эндокардита, требующего операции на открытом сердце

15 October 2020 in Research Square
Verified
Preprint
Open access
PDF file
RKRymbay Kaliyev
Rymbay Kaliyev
TLTimur Lesbekov
Timur Lesbekov
SBSerik Bekbossynov
Serik Bekbossynov
ZNZhuldyz Nurmykhametova
Zhuldyz Nurmykhametova
ASAliya Sailybayeva
Aliya Sailybayeva
YPYuriy Pya
Yuriy Pya
Background: Organ Care System (OCS) minimizes the cold ischemic time and allows for optimization of logistics and meticulous recipient preparation. Impact of normothermic ex-vivo preservation using OCS compared with cold storage (CS) for prolonged heart preservation especially beneficial for high-risk recipients bridged to transplantation with Mechanical Circulatory Support (MCS).Methods: Between 2012 and 2018, we performed a retrospective single-center review of prospectively collected data. All patients who underwent heart transplantation with MCS using the OCS Heart (n=25) versus standard cold storage (n=10) were included in this study. Results: During this period, 353 patients were implanted with left ventricular assisted device (LVAD) and 35 (10 %) were bridged to heart transplantation. There was no significant difference in donor and recipient characteristics and risk factors. The Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was a trend towards higher estimated risk of death at 1y in the OCS group (14.2 vs. 10.8% p= 0.083). Mean total ischemic time during preservation was statistically significantly longer in CS vs OCS group (210 (23) Vs 74.6 (13) min p=0.001). Median ex vivo normothermic heart perfusion time in OCS was 348.4(132; 955) min. There was significant difference in total out of body time between OCS group 423(67) Vs CS group 210(23) min p=0.002). All patients were alive on the 30th days post implant in CS groups and 96% in OCS group (p=0.5).Conclusion: Normothermic ex-vivo preservation of the allograft during transportation with the organ care system might be beneficial for long-time out of body organ preservation in comparison of cold storage especially for recipients on mechanical circulatory support.