Ser Garcia

Dr. Ser Garcia

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Revista Clínica Española
Verified
Journal Article
Closed access
ACA.M. Costa-Alcaraz
A.M. Costa-Alcaraz
JSJ.C. Siurana-Aparisi
J.C. Siurana-Aparisi
CAC. Almendro-Padilla
C. Almendro-Padilla
SGSer Garcia
Ser Garcia
ROR. Ordovás-Casaurrán
R. Ordovás-Casaurrán

1 November 2015 in Nefrología
Verified
Journal Article
Open access
SGSer Garcia
Ser Garcia
MSMaría Morales Suárez-Varela
María Morales Suárez-Varela
AMAnna Martí Monrós
Anna Martí Monrós
AGAgustín Llopis González
Agustín Llopis González
The environmental impact of haemodialysis is very high. Institutional activity in this sense is important, even in the production of references. Voluntary environmental management systems (EMS), environmental management and auditing systems (EMAS) and the International Organization for Standardization standards (ISO 14001) are important tools for environmental protection, together with legislation, taxation and tax benefits. To determine the degree of implementation of EMS in hospital units and outpatient haemodialysis in the Spanish National Health System to provide a group of reference centres in environmental management in this healthcare activity. Development of a list by autonomous communities showing hospital and outpatient dialysis units using an EMAS and/or ISO 14001 in 2012-2013. The sources of information were the Spanish National Catalogue of Hospitals, Spanish Registry of Healthcare Certification and Accreditation, European and regional EMAS records, world ISO registrations, dialysis centre lists from scientific societies and patients, responses from accredited entities in Spain for environmental certification and the institutional website of each haemodialysis centre identified. Of the 210 hospitals with a dialysis unit, 53 (25%) have the ISO 14001 and 15 of these also have an EMAS). This constitutes 30% of all hospital dialysis chairs in Spain: 1,291 (of 4,298). Only 11 outpatient clinics are recorded, all with the ISO 14001. There is no official documentation of the implementation of EMS in dialysis units. Making this list provides an approach to the situation, with special reference to haemodialysis because of its significant environmental impact.

10 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CFCarlos Fernández-Vizcaino
Carlos Fernández-Vizcaino
CRCARMEN NARANJO - RUIZ
CARMEN NARANJO - RUIZ
NFNadia Fernandez-Ehrling
Nadia Fernandez-Ehrling
SGSer Garcia
Ser Garcia
EGEduardo Nieto García
Eduardo Nieto García
Javier Ferrer-TorregrosaJavier Ferrer-Torregrosa
Javier Ferrer-Torregrosa
Background: Metatarsalgia is a common pathology that is initially treated conservatively, but failure to do so requires surgery, such as the minimally invasive distal metatarsal osteotomy (DICMO). Methods: In this prospective study of 65 patients with primary metatarsalgia who underwent DICMO, plantar pressures, American Orthopaedic Foot and Ankle Society MetaTarsoPhalangeal-InterPhalangeal scale (AOFAS-MTP-IP) and Visual Analog Scale (VAS) were evaluated pre-operatively and post-operatively and there was a subgroup in which an inclinometer was used to observe the importance of the inclination of the osteotomy. Results: The results show a significant reduction in plantar pressures after DICMO surgery without overloading the adjacent radii, especially in the subgroup with an inclinometer to guide the osteotomy. The AOFAS-MTP-IP scale evidenced a marked improvement in metatarsal function and alignment with scores close to normal. The VAS scale showed a substantial decrease in pain after DICMO osteotomy. Conclusions: DICMO, with an inclinometer for a 45° osteotomy, proved to be a safe and effective procedure for primary metatarsalgia, although further comparative studies are needed to confirm its superiority.

29 November 2015 in Journal of Renal Care
Verified
Journal Article
Closed access
PDF file
SGSer Garcia
Ser Garcia
AGAgustin Llopis González
Agustin Llopis González
CGC. González‐Steinbauer
C. González‐Steinbauer
MSM. Morales Suárez‐Varela
M. Morales Suárez‐Varela

Javier Ferrer-TorregrosaJavier Ferrer-Torregrosa
Javier Ferrer-Torregrosa
SGSer Garcia
Ser Garcia
NFNadia Fernández-Ehrling
Nadia Fernández-Ehrling
JTJavier Torralba-Estellés
Javier Torralba-Estellés
CBCarlos Barrios
Carlos Barrios
Background: Precision in minimal-incision surgery allows surgeons to achieve accurate osteotomies and patients to avoid risks. Herein, a surgical guide for the foot is designed and validated in vitro using resin foot models for hallux abducto valgus surgery. Methods: Three individuals with different experience levels (an undergraduate student, a master's student, and an experienced podiatric physician) performed an Akin osteotomy, a Reverdin osteotomy, and a basal osteotomy of the first metatarsal. Results: The average measurements of each osteotomy and the angle of the basal osteotomy do not reveal significant differences among the three surgeons. A shorter deviation from the planned measurements has been observed in variables corresponding to the Akin osteotomy (the maximum deviation in the measurement of the distance from the proximal medial end of the Akin osteotomy to the first metatarsophalangeal joint interline was 1.67 mm, and the maximum deviation from the proximal lateral end of the Akin osteotomy to the first metatarsophalangeal joint interline was 1.00 mm). As for the Reverdin osteotomies, the maximum deviations in the measurement of the distance from the proximal medial end of the osteotomy to the first metatarsophalangeal joint interline were 3.60 and 3.53 mm in the expert and undergraduate surgeons, respectively. All of the osteotomies were precise among the groups, reducing the learning curve to the maximum. Conclusions: The three-dimensional–printed prototype has been proven effective in guiding surgeons to perform different types of osteotomies. Minimal deviations from the predefined osteotomies were found among the three surgeons.

2 October 2024 in Medicina
Verified
Journal Article
Open access
PDF file
NFNadia Fernandez-Ehrling
Nadia Fernandez-Ehrling
EGEduardo Nieto García
Eduardo Nieto García
LRLEONOR RAMIREZ
LEONOR RAMIREZ
EGElena Nieto Gonzalez
Elena Nieto Gonzalez
CBCarlos Barrios
Carlos Barrios
Javier Ferrer-TorregrosaJavier Ferrer-Torregrosa
Javier Ferrer-Torregrosa
Background/Objectives: Hallux valgus is a common foot deformity that requires surgical correction to restore proper alignment. Precision in the osteotomies performed during these surgeries is critical to avoid complications and improve outcomes. However, variability in surgeon experience can negatively affect precision. In this context, advances in 3D printing have enabled the development of customized surgical guides, which may enhance precision and reduce variability among surgeons with different levels of expertise. This study aims to evaluate the effectiveness of a 3D-printed surgical guide in minimally invasive hallux valgus correction, focusing on the accuracy of osteotomies performed by novice surgeons, experienced surgeons, and theoretically trained consultants. Methods: An ex vivo study was performed with 30 cadaveric feet, divided into three groups according to the level of experience of the surgeons: 3D guide group, Master’s students, professionals. All surgeons performed Akin and Reverdin-Isham osteotomies, but the experimental group (the 3D guide group) utilized a customized 3D-printed surgical guide for enhanced precision during these procedures. Radiographic measurements of osteotomy angles and alignment were taken after the interventions, and compared with the planned values. Statistical analyses were conducted to evaluate the variability in the precision of the cuts. Results: The use of the 3D-printed surgical guide significantly reduced angular variability in the experienced group, achieving higher levels of accuracy than experienced surgeons. Effect sizes, which ranged from small to large, indicated a greater impact on angle measurements (η2 = 0.46, p < 0.001); no significant differences were found between the groups in other evaluated parameters. Conclusions: The incorporation of 3D-printed surgical guides in hallux valgus surgery significantly improves osteotomy accuracy, particularly in less experienced surgeons. This suggests that these guides can help standardize procedures, reduce the learning curve, and lower intraoperative complications.