Sophia K Theodossiou

Dr. Sophia K Theodossiou


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Biomaterials
Verified
Journal Article
Closed access
JJJohn S.K. Yuen Jr
John S.K. Yuen Jr
ASAndrew J. Stout
Andrew J. Stout
NKN. Stephanie Kawecki
N. Stephanie Kawecki
SLSophia M. Letcher
Sophia M. Letcher
STSophia K Theodossiou
Sophia K Theodossiou
DKDavid Kaplan
David Kaplan

29 November 2019 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
STSophia K Theodossiou
Sophia K Theodossiou
NSNathan R Schiele
Nathan R Schiele
Tendons link muscle to bone and transfer forces necessary for normal movement. Tendon injuries can be debilitating and their intrinsic healing potential is limited. These challenges have motivated the development of model systems to study the factors that regulate tendon formation and tendon injury. Recent advances in understanding of embryonic and postnatal tendon formation have inspired approaches that aimed to mimic key aspects of tendon development. Model systems have also been developed to explore factors that regulate tendon injury and healing. We highlight current model systems that explore developmentally inspired cellular, mechanical, and biochemical factors in tendon formation and tenogenic stem cell differentiation. Next, we discuss in vivo,in vitro,ex vivo,and computational models of tendon injury that examine how mechanical loading and biochemical factors contribute to tendon pathologies and healing. These tendon development and injury models show promise for identifying the factors guiding tendon formation and tendon pathologies, and will ultimately improve regenerative tissue engineering strategies and clinical outcomes.

1 January 2018 in MethodsX
Verified
Journal Article
Open access
ARAbigail R. Raveling
Abigail R. Raveling
STSophia K Theodossiou
Sophia K Theodossiou
NSNathan R Schiele
Nathan R Schiele
Mechanical loading is an important cue for directing stem cell fate and engineered tissue formation in vitro. Stem cells cultured on 2-dimensional (D) substrates and in 3D scaffolds have been shown to differentiate toward bone, tendon, cartilage, ligament, and skeletal muscle lineages depending on their exposure to mechanical stimuli. To apply this mechanical stimulus in vitro, mechanical bioreactors are needed. However, current bioreactor systems are challenged by their high cost, limited ability for customization, and lack of force measurement capabilities. We demonstrate the use of 3-dimensional printing (3DP) technology to design and fabricate a low-cost custom bioreactor system that can be used to apply controlled mechanical stimuli to cells in culture and measure the mechanical properties of small soft tissues. The results of our in vitro studies and mechanical evaluations show that 3DP technology is feasible as a platform for developing a low-cost, customizable, and multifunctional mechanical bioreactor system. • 3DP technology was used to print a multifunctional bioreactor system/tensile load frame for a fraction of the cost of commercial systems. • The system mechanically stimulated cells in culture and evaluated the mechanical properties of soft tissues. • This system is easily customizable and can be used to evaluate multiple types of soft tissues.

16 February 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
AGAnthony Tushar Giduthuri
Anthony Tushar Giduthuri
STSophia K Theodossiou
Sophia K Theodossiou
NSNathan R Schiele
Nathan R Schiele
Soumya SrivastavaSoumya Srivastava
Soumya Srivastava
Tendons are collagenous musculoskeletal tissues that connect muscles to bones and transfer the forces necessary for movement. Tendons are susceptible to injury and heal poorly, with long-term loss of function. Mesenchymal stem cell (MSC)-based therapies are a promising approach for treating tendon injuries but are challenged by the difficulties of controlling stem cell fate and of generating homogenous populations of stem cells optimized for tenogenesis (differentiation toward tendon). To address this issue, we aim to explore methods that can be used to identify and ultimately separate tenogenically differentiated MSCs from non-tenogenically differentiated MSCs. In this study, baseline and tenogenically differentiating murine MSCs were characterized for dielectric properties (conductivity and permittivity) of their outer membrane and cytoplasm using a dielectrophoretic (DEP) crossover technique. Experimental results showed that unique dielectric properties distinguished tenogenically differentiating MSCs from controls after three days of tenogenic induction. A single shell model was used to quantify the dielectric properties and determine membrane and cytoplasm conductivity and permittivity. Together, cell responses at the crossover frequency, cell morphology, and shell models showed that changes potentially indicative of early tenogenesis could be detected in the dielectric properties of MSCs as early as three days into differentiation. Differences in dielectric properties with tenogenesis indicate that the DEP-based label-free separation of tenogenically differentiating cells is possible and avoids the complications of current label-dependent flow cytometry-based separation techniques. Overall, this work illustrates the potential of DEP to generate homogeneous populations of differentiated stem cells for applications in tissue engineering and regenerative medicine.

1 January 2019 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
STSophia K Theodossiou
Sophia K Theodossiou
JTJohn Tokle
John Tokle
NSNathan R Schiele
Nathan R Schiele

7 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
CJCalvin L Jones
Calvin L Jones
BPBrian T. Penney
Brian T. Penney
STSophia K Theodossiou
Sophia K Theodossiou
The extracellular microenvironment regulates many of the mechanical and biochemical cues that direct musculoskeletal development and are involved in musculoskeletal disease. The extracellular matrix (ECM) is a main component of this microenvironment. Tissue engineered approaches towards regenerating muscle, cartilage, tendon, and bone target the ECM because it supplies critical signals for regenerating musculoskeletal tissues. Engineered ECM–material scaffolds that mimic key mechanical and biochemical components of the ECM are of particular interest in musculoskeletal tissue engineering. Such materials are biocompatible, can be fabricated to have desirable mechanical and biochemical properties, and can be further chemically or genetically modified to support cell differentiation or halt degenerative disease progression. In this review, we survey how engineered approaches using natural and ECM-derived materials and scaffold systems can harness the unique characteristics of the ECM to support musculoskeletal tissue regeneration, with a focus on skeletal muscle, cartilage, tendon, and bone. We summarize the strengths of current approaches and look towards a future of materials and culture systems with engineered and highly tailored cell–ECM–material interactions to drive musculoskeletal tissue restoration. The works highlighted in this review strongly support the continued exploration of ECM and other engineered materials as tools to control cell fate and make large-scale musculoskeletal regeneration a reality.