The present contribution addresses the analysis of the leakage behavior of a small hydro Francis turbine using an analytical approach, which was validated based on the results of computational fluid dynamics (CFD). For a custom-designed Francis turbine with a specific speed of nq = 41.9 rpm, the flow chambers resulting from the labyrinth geometry were added to a traditional full CFD model of the turbine and numerical simulations were performed for several operation points ranging from part load (Qmin = 0.5 × Qopt) to over load (Qmax = 1.3 × Qopt). Consequently, the single losses occurring in the runner seals on crown and band side as well as the pressure distribution within the runner side spaces could be evaluated and compared to the results gained with an analytical approach, which was originally developed to calculate the leakage flow of centrifugal pumps. The comparison of the pressure distribution achieved with the numerical simulation and the analytical calculation shows that both approaches match well if the angular velocity of the fluid ωFluid trapped in the runner side spaces is calculated in an appropriate way. Furthermore, the achieved results demonstrate that the use of the analytical model enables the calculation of the disk friction and leakage losses with sufficient accuracy. This paper contributes to the improvement of the performance prediction of Francis turbines based on combined numerical and analytical calculations.
The complex flow conditions in Pelton turbines make it challenging to gain detailed insight into the local flow processes. However, CFD methods offer vast potential for developing and optimising Pelton turbines due to these flow conditions. In a comprehensive examination, a six-nozzle prototype Pelton turbine with 19 buckets has been investigated using 3D CFD simulations. First, the steady simulations of the manifold and the unsteady runner simulation have been performed with a mesh-based, commercial CFD code, whereby a two-equation turbulence model and the homogeneous two-phase model were used. Then, to limit the simulation time, symmetry was applied in the runner simulation, and also a strategic definition of the mesh element size in selected blocks of higher interest. Subsequently, the simulation results were analysed. Based on the first simulation results, the geometry of the distributor was modified in an iterative process to reduce losses and improve the jet shape. For the improvement of the latter, a characteristic number was introduced to quantify the secondary flows upstream of the nozzles, which act negatively on the jet shape. Furthermore, the results of the runner simulation were analysed with special regard to the jet-bucket interaction from the start to the end of the impingement cycle of a particular bucket. Finally, a potential efficiency increase could be derived from the summary.
Side channel pumps provide high pressure at relatively low flow rates. This comes along with a quite low specific speed and thus with the known disadvantage of a quite poor maximum efficiency. This paper describes the detailed analysis and optimisation of a typical 1-stage side channel pump with an additional radial suction impeller by means of computational fluid dynamics (CFD) simulations. In a first step, the model was successively generated and it was obvious that it has to contain all details including suction impeller and main stage (both 360° models) as well as the pressure housing and all narrow gaps to provide useful simulation results. Numerical simulations were carried out in a stationary and transient way with scale resolving turbulence models to analyse the components in detail. Finally the CFD-simulations were validated with model tests. For the optimisation process it was necessary to generate a reduced numerical model to analyse the effects of more than 300 geometry variations. The findings were then combined to establish the desired objectives. Finally the best combinations were validated again with the full numerical model. Those simulations predict a relative efficiency increase at best efficiency point (BEP) and part load >30% with respect to all given limitations like identical head curve, suction behavior, and dimensions.
Besides operating a centrifugal pump under normal conditions there are additional operating conditions possible; for example, a pump operated as turbine. Another example would be a pump trip where there are several abnormal operating conditions possible when the direction of flow and/or the direction of rotation are changing. The machine behavior in every possible operation condition can be represented by the complete pump characteristics, often called the 4-quadrant (4Q) behavior of a centrifugal pump. To gather the 4Q behavior, a test rig allowing the flow direction as well as the rotation direction to be reverted is necessary, with time-consuming measurements at variable positive and negative discharge in both directions of rotation the complete pump characteristics are evaluated. In the present study, an approach to investigate the complete pump characteristics by means of computational fluid dynamics (CFD) calculations is presented. With steady-state calculations and additional transient CFD investigations in the normal operating conditions, the whole pump characteristics were calculated accurately. Two different types of mixed flow diffuser pumps were investigated—one equipped with adjustable impeller blades, the second one with comparable low specific speed. Experimental verifications have shown a remarkably good agreement. Furthermore, an exemplary numerical waterhammer analysis shows the successful application of the presented approach.
1 June 2021 in IOP Conference Series: Earth and Environmental Science
Fish migrating downstream may face an increased risk of injury when passing through hydropower turbines. The overall influence on fish populations remains unknown. Still, it is undoubtedly linked to the damage potential of the turbines, the stage of maturity and the size of the migrating individuals as well as the proportion of migrating fish in relation to the total population. The sources of injury are usually the contact to the turbine blade and the rapid pressure drop in the turbine as well as shear forces, and large-scale turbulence. The authors investigated the conditions experienced by fish migrating through a 5-bladed vertical Kaplan turbine, each of the two units with a nominal power of 45 MW. Therefore, so-called “Barotrauma Detection Sensors (BDS)” were applied to determine the physical parameters during the turbine passages. Additionally, live fish, fitted externally with Barotrauma Detection Sensors, were introduced.
27 March 2019 in IOP Conference Series: Earth and Environmental Science
Before the invention of the Kaplan turbine, Francis turbines were also built as twin Francis turbines. An example for such a single-regulated horizontal axis twin Francis turbine is the hydro power plant Meitingen – 3 units with an inlet chamber and a single-sided shaft led through. This plant, which is located on a diversion channel, went in operation in 1922 with a nominal power of 11.6 MW for the three machine sets providing an annual production of 72.6 GWh. Due to cracks and cavitation damages, one of the units should be replaced, yet, after a comprehensive study the decision for a major mechanical and electrical refurbishment was taken. The geometry was scanned on-site and a CAD model was generated. The RANS calculation for the whole power plant provided information on the overall performance, the losses referring to each component and the flow situation in each of the turbines. An optimization of the runner design was carried out and an increase of 14.8% of the annual production could be realized. All of the units were brought into operation after the refurbishment and the performance level was checked successfully by means of an on-site efficiency measurement campaign according to IEC 60041.