Qiuqin Sun

Dr. Qiuqin Sun

College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2016 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
FWFeng Wang
Feng Wang
JFJingmin Fan
Jingmin Fan
Qiuqin SunQiuqin Sun
Qiuqin Sun
QJQinji Jiang
Qinji Jiang
SCShe Chen
She Chen
WZWu Zhou
Wu Zhou
The content of hydrogen is a key quantity in condition assessment and fault diagnosis of power transformer. Based on the density functional theory (DFT), the adsorption mechanism of Cu-doped SnO2 surface toward H2 has been systematically studied in this work. Firstly, the relaxation, the bond length, and overlap population of both the pure and Cu-doped SnO2 are computed. To determine the optimal doping position, the formation energies of four potential sites (i.e., Sn5c, Sn6c, Sn5c-s, and Sn6c-s) are then compared with each other. The adsorption energy and the electronic structure of SnO2 surface are analysed and discussed in detail. Furthermore, to estimate the partial atomic charges and the electrical conductance, the Mulliken population analysis is also performed. It has been found that the bridge oxygen is the most favourable position. The partial density of states of H2 after adsorption is broadened and shifted close to the Fermi level. A large amount of charges would be transferred and then released back into its conduction band, leading to the reduction of resistance and the enhancement of sensitivity toward H2. The results of this work provide references for SnO2-based sensor design.

2 August 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JFJingmin Fan
Jingmin Fan
FWFeng Wang
Feng Wang
Qiuqin SunQiuqin Sun
Qiuqin Sun
FBFeng Bin
Feng Bin
FLFangwei Liang
Fangwei Liang
XXXuanyi Xiao
Xuanyi Xiao
Dissolved gas analysis (DGA) is a popular method for diagnosing faults inside power transformers. However, some of the recorded data for the analysis are with ambiguous characteristic, leading to misdiagnosis of conventional methods. In this work, a hybrid method, which combines the relevance vector machine (RVM) and the adaptive neural fuzzy inference system (ANFIS) has been proposed to address this issue. Given the fuzziness between DGA records and fault type, and to minimise the number of rules that ANFIS needs to extract, the RVM algorithm performs binary separation firstly, and then ANFIS is utilised to achieve further fault diagnosis in this study. The experimental results demonstrate that the hybrid RVM–ANFIS algorithm can achieve an accuracy rate as high as 95%. Moreover, the proposed algorithm exceeds single ANFIS, support vector machine, and artificial neural network on distinguishing multiple faults and samples with ambiguous characteristic. The engineering application results also demonstrate the effectiveness and superiority of the proposed RVM–ANFIS.

31 July 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JFJingmin Fan
Jingmin Fan
FWFeng Wang
Feng Wang
Qiuqin SunQiuqin Sun
Qiuqin Sun
FBFeng Bin
Feng Bin
HYHuisheng Ye
Huisheng Ye
YLYuhan Liu
Yuhan Liu
In this paper, an online monitoring system based on a SnO 2 gas chromatographic detector for power transformer condition assessment is developed. For a quantitative analysis of feature gases dissolved in transformer oil, a mathematical model derived from the chemistry and semiconductor theory is proposed. On the basis of this, gas chromatography measurement module along with electronic controlling and data sampling system is designed and integrated. A series of repeatability test and quantitative analysis has been performed; the repeatability performance is excellent for given concentrations; the measurement accuracy based on the proposed mathematical model for the feature gases shows good suitability. Furthermore, the transformer diagnosis is performed for identifying fault types. The experimental and practical application results demonstrate the effectiveness of this system.

15 June 2024 in Measurement
Verified
Journal Article
Closed access
Qiuqin SunQiuqin Sun
Qiuqin Sun
KQKang Qiu
Kang Qiu
ZZZhi Zheng
Zhi Zheng
XLXiaofeng Lu
Xiaofeng Lu
LDLumei Du
Lumei Du
Qiuqin SunQiuqin Sun
Qiuqin Sun

1 April 2019 in Journal of Fluorine Chemistry
Verified
Journal Article
Closed access
LZLipeng Zhong
Lipeng Zhong
SJShengchang Ji
Shengchang Ji
FWFeng Wang
Feng Wang
Qiuqin SunQiuqin Sun
Qiuqin Sun
SCShe Chen
She Chen
LTLu Tang
Lu Tang

27 November 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JFJingmin Fan
Jingmin Fan
FWFeng Wang
Feng Wang
Qiuqin SunQiuqin Sun
Qiuqin Sun
FBFeng Bin
Feng Bin
JDJiafeng Ding
Jiafeng Ding
HYHuisheng Ye
Huisheng Ye
Dissolved gas analysis (DGA) is widely used in diagnosing the incipient faults of power transformer. The detector is the key component for this method. Despite various sensors for DGA application, many of them suffer from poor stability and low sensitivity. A solid oxide fuel cell (SOFC) detector is designed in this paper to address these problems. The mechanism of the detector is briefly introduced, and it is fabricated in a mold. The test process is elucidated. For calibration purpose, two mathematical models of the detector, i.e., double-logarithmic model (DLM) and linearity model (LM), are compared with each other. Experimental results demonstrate that the SOFC detector exhibits good repeatability at given concentrations and excellent linearity with DLM. The results indicate that accurate and high-precision measurement of H2, CH4, CO, C2H4, C2H6, and C2H2 can be achieved using the SOFC detector and the proposed DLM.