Ali Alenezi

Dr. Ali Alenezi

Assistant Professor,
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
AAAli Alenezi
Ali Alenezi
MAMohammad Alsweed
Mohammad Alsweed
SMSaleh Mohammad
Saleh Mohammad
Bruno Ramos ChrcanovicBruno Ramos Chrcanovic
Bruno Ramos Chrcanovic
The presented study aimed to assess the survival rate of porcelain laminate veneers (PLV) based on a systematic review of the literature. An electronic search was last updated in February 2021. Eligibility criteria included clinical series of patients rehabilitated with PLVs published in the last 25 years, with a minimum follow-up of 3 years. Survival analysis methods were applied. Twenty-five studies were included, with 6500 PLVs. The 10-year estimated cumulative survival rate (CSR) of PLVs was 95.5%. The 10-year CSR of PLVs when fracture, debonding, occurrence of secondary caries, and need of endodontic treatment were considered as isolated reasons for failure were 96.3%, 99.2%, 99.3%, and 99.0%, respectively. PLVs without incisal coverage had a higher failure rate than PLVs with incisal coverage. Non-feldspathic PLVs performed better than feldspathic PLVs. As a conclusion, the 10-year CSR of PLVs was 95.5%, when fracture, debonding, occurrence of secondary caries, and need of endodontic treatment were considered as reasons for restoration failure. Fracture seems to be most common complication of PLVs, followed by debonding, with both more commonly happening within the first years after PLV cementation. PLVs with incisal coverage and non-feldspathic PLVs presented lower failure rates than PLVs without incisal coverage and feldspathic PLVs.

31 October 2022 in Journal of Family Medicine and Primary Care
Verified
Journal Article
Open access
AAAli Alenezi
Ali Alenezi
HAHamad S. Aldokhayel
Hamad S. Aldokhayel
A BSTRACT: Objective: The aim is to investigate the causes of dental fear and its impact on dental attendance behaviors. Materials and Methods: A short questionnaire was distributed to participants at different dental clinics and by emails to evaluate their perceptions of dental fear. The questionnaire contained questions related to gender and age group. The remaining part of the questionnaire investigated the causes of dental fear and its impact on dental visits. Results: A total of 2264 participants aged 18 years and above agreed to complete the questionnaire. There were 1177 (52%) male participants and 1095 (48%) female participants. There was a response rate of approximately 60%. Drilling tooth devices and their sounds was the option that caused the highest dental fear among the participants who had it ( n = 248; 37.7%). Pain was the second most frequently chosen option to cause dental fear ( n = 165; 25%). Around 70% ( n = 1257) of the participants who had dental fear overcame their fear and decided to seek treatment when they experienced annoying pain. At the same time, 18% ( n = 323) of them sought the treatment when they experienced slight pain and 10% ( n = 180) sought the treatment once they noticed a large carious lesion. Conclusion: People from both genders responded similarly to dental fear, and age was not found to be a significant factor in individuals’ reactions to dental treatment. The sounds of teeth-drilling devices and related sounds may be responsible for the dental fear, as reported by many people. People with dental fear are more likely to avoid regular dental visits.

26 November 2022 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
AAAli Alenezi
Ali Alenezi
OAOmar Alkhudhayri
Omar Alkhudhayri
FAFahad Altowaijri
Fahad Altowaijri
LALina Aloufi
Lina Aloufi
FAFatimah Alharbi
Fatimah Alharbi
DADhafer Al Asmari
Dhafer Al Asmari
Objectives: Even with excellent fixed dental prostheses (FDPs), there will be a substantial risk of biological complications, such as caries, if proper oral hygiene is not maintained. This study aimed to evaluate the risks of developing secondary caries with FDPs in relation to the patient oral hygiene status.Material and Methods: Clinical and radiographic examinations were performed for patients to collect data related to their FDP complications and oral hygiene status. The main clinical parameter analyzed was secondary caries. Complications such as a fracture, debonding, or the need for endodontic therapy were also analyzed. The interval survival rate and the cumulative survival rate of FDPs from the time of treatment to the time of follow‐up were analyzed.Results: A total of 423 patients (with a total of 1116 FDPs) were examined in this study, with a mean age of 43.7 years and a mean follow‐up time of 7 years. Regarding complications, secondary caries was detected in 94 FDPs (8.4%), fracture (or chipping) in 85 (7.6%) cases, need for endodontic treatment in 42 cases (3.7%), and debonding in four (0.3%) cases. Secondary caries was found in nine out of 219 FDPs (4%) in patients with good oral hygiene, 35 out of 634 FDPs (5.5%) in patients with fair oral hygiene, and 50 out of 272 FDPs (18.4%) in patients with poor oral hygiene (p ≤ .001).Conclusions: Good oral hygiene has a great influence on reducing the risk of secondary caries in patients with FDPs. The occurrence of secondary caries is a common complication in patients with poor oral hygiene.

1 January 2018 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
AAAli Alenezi
Ali Alenezi
Bruno Ramos ChrcanovicBruno Ramos Chrcanovic
Bruno Ramos Chrcanovic
AWAnn Wennerberg
Ann Wennerberg
Ali Alenezi, BDS, MSc/Bruno Chrcanovic, DDS, MSc/Ann Wennerberg, DDS, PhD: Purpose: One of the suggested methods for enhancing osseointegration is the local application of drug agents around implant surfaces. The aim of this review was to evaluate the methods most commonly used for local drug and chemical compound delivery to implant sites and assess their influence on osseointegration. Materials and Methods: An electronic search was undertaken in three databases (PubMed, Scopus, Embase). The search was limited to animal experiments using endosseous implants combined with local drug delivery systems. Meta-analyses were performed for the outcome bone-to-implant contact (BIC). Results: Sixty-one studies met the inclusion criteria. Calcium phosphate (CaP), bisphosphonates (BPs), and bone morphogenetic proteins (BMPs) were the most commonly used chemical compounds. There were two main methods for local drug delivery at the bone-implant interface: (1) directly from an implant surface by coating or immobilizing techniques, and (2) the local application of drugs to the implant site, using carriers. There was a statistically significant increase in BIC for both local drug delivery methods (P = .02 and P < .0001, respectively) compared with the control methods. There was a statistically significant increase in BIC when CaP (P = .0001) and BMPs (P = .02) were either coating implants or were delivered to the implant site, in comparison to when drugs were not used. The difference was not significant for the use of BPs (P = .15). Conclusion: It is suggested that the use of local chemical compound delivery systems around implants could significantly improve implant osseointegration in animal models. It is a matter of debate whether these in vivo results might have some significant effect in the human clinical setting in the long term.

15 June 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
AAAli Alenezi
Ali Alenezi
SASarah Aloqayli
Sarah Aloqayli
Backgrounds: Long-span dental bridges may cause excessive load on abutment teeth and the periodontal area, which may lead to bridge fractures or periodontal problems. However, some reports have revealed that short- and long-span bridges can provide a similar prognosis. This clinical study aimed to investigate the technical complications associated with fixed dental prostheses (FDPs) of different span lengths. Methods: All patients with previously cemented FDPs were clinically examined during their follow-up visits. Several data related to FDPs were registered, such as design, material type, location, and type of complication. The main clinical factors analyzed were technical complications. Life table survival analyses were performed to calculate the cumulative survival rate of FDPs when technical complications were detected. Results: The study examined 229 patients with a total number of 258 prostheses and an average of 98 months of follow-up. Seventy-four prostheses suffered from technical complications, and the most common complication was ceramic fracture or chipping (n = 66), while loss of retention occurred in 11 prostheses. The long-term evaluation of long-span prostheses revealed a significantly higher technical complication rate compared to short-span prostheses (P = ,003). The cumulative survival rate for short-span FDPs was 91% in year 5, 68% in year 10, and 34% in year 15. For long-span FDPs, the cumulative survival rate was 85% in year 5, 50% in year 10, and 18% in year 15. Conclusion: Long-span prostheses (5 units or more) can be associated with a higher technical complication rate compared to short-span prostheses after long-term evaluation.

12 October 2019 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Open access
PDF file
AAAli Alenezi
Ali Alenezi
SGSilvia Galli
Silvia Galli
SASaba Atefyekta
Saba Atefyekta
MAMartin Andersson
Martin Andersson
AWAnn Wennerberg
Ann Wennerberg
Background: Numerous studies have reported the beneficial effects of strontium on bone growth, particularly by stimulating osteoblast proliferation and differentiation. Thus, strontium release around implants has been suggested as one possible strategy to enhance implant osseointegration. Aim: This study aimed to evaluate whether the local release of strontium ranelate (Sr-ranelate) from implants coated with mesoporous titania could improve bone formation around implants in an animal model. Materials and methods: Mesoporous titania (MT) thin coatings were formed utilizing the evaporation induced self-assembly (EISA) method using Pluronic (P123) with or without the addition of poly propylene glycol (PPG) to create materials with two different pore sizes. The MT was deposited on disks and mini-screws, both made of cp Ti grade IV. Scanning electron microscopy (SEM) was performed to characterize the MT using a Leo Ultra55 FEG instrument (Zeiss, Oberkochen, Germany). The MT was loaded with Sr-ranelate using soaking and the drug uptake and release kinetics to and from the surfaces were evaluated using quartz crystal microbalance with dissipation monitoring (QCM-D) utilizing a Q-sense E4 instrument. For the in vivo experiment, 24 adult rats were analyzed at two time points of implant healing (2 and 6 weeks). Titanium implants shaped as mini screws were coated with MT films and divided into two groups; supplied with Sr-ranelate (test group) and without Sr-ranelate (control group). Four implants (both test and control) were inserted in the tibia of each rat. The in vivo study was evaluated using histomorphometric analyses of the implant/bone interphase using optical microscopy. Results: SEM images showed the successful formation of evenly distributed MT films covering the entire surface with pore sizes of 6 and 7.2 nm, respectively. The QCM-D analysis revealed an absorption of 3300 ng/cm2 of Sr-ranelate on the 7.2 nm MT, which was about 3 times more than the observed amount on the 6 nm MT (1200 ng/cm2). Both groups showed sustained release of Sr-ranelate from MT coated disks. The histomorphometric analysis revealed no significant differences in bone implant contact (BIC) and bone area (BA) between the implants with Sr-ranelate and implants in the control groups after 2 and 6 weeks of healing (BIC with a p-value of 0.43 after 2 weeks and 0.172 after 6 weeks; BA with a p-value of 0.503 after 2 weeks, and 0.088 after 6 weeks). The mean BIC and BA values within the same group showed significant increase among all groups between 2 and 6 weeks. Conclusion: This study could not confirm any positive effects of Sr-ranelate on implant osseointegration.