Radiochromic film has become an important tool to verify dose distributions for intensity‐modulated radiotherapy (IMRT) and quality assurance (QA) procedures. A new radiochromic film model, EBT3, has recently become available, whose composition and thickness of the sensitive layer are the same as those of previous EBT2 films. However, a matte polyester layer was added to EBT3 to prevent the formation of Newton's rings. Furthermore, the symmetrical design of EBT3 allows the user to eliminate side‐orientation dependence. This film and the flatbed scanner, Epson Perfection V750, form a dosimetry system whose intrinsic characteristics were studied in this work. In addition, uncertainties associated with these intrinsic characteristics and the total uncertainty of the dosimetry system were determined. The analysis of the response of the radiochromic film (net optical density) and the fitting of the experimental data to a potential function yielded an uncertainty of 2.6%, 4.3%, and 4.1% for the red, green, and blue channels, respectively. In this work, the dosimetry system presents an uncertainty in resolving the dose of 1.8% for doses greater than 0.8 Gy and less than 6 Gy for red channel. The films irradiated between 0 and 120 Gy show differences in the response when scanned in portrait or landscape mode; less uncertainty was found when using the portrait mode. The response of the film depended on the position on the bed of the scanner, contributing an uncertainty of 2% for the red, 3% for the green, and 4.5% for the blue when placing the film around the center of the bed of scanner. Furthermore, the uniformity and reproducibility radiochromic film and reproducibility of the response of the scanner contribute less than 1% to the overall uncertainty in dose. Finally, the total dose uncertainty was 3.2%, 4.9%, and 5.2% for red, green, and blue channels, respectively. The above uncertainty values were obtained by minimizing the contribution to the total dose uncertainty of the film orientation and film homogeneity.PACS number(s): 87.53.Bn

7 January 2015 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JLJosé Manuel Lárraga-Gutiérrez
José Manuel Lárraga-Gutiérrez
PBPaola Ballesteros-Zebadúa
Paola Ballesteros-Zebadúa
MRMiguel Rodríguez-Ponce
Miguel Rodríguez-Ponce
OGOlivia Amanda García Garduño
Olivia Amanda García Garduño
OCOlga Olinca Galván de la Cruz
Olga Olinca Galván de la Cruz
A CVD based radiation detector has recently become commercially available from the manufacturer PTW-Freiburg (Germany). This detector has a sensitive volume of 0.004 mm 3 , a nominal sensitivity of 1 nC Gy −1 and operates at 0 V. Unlike natural diamond based detectors, the CVD diamond detector reports a low dose rate dependence. The dosimetric properties investigated in this work were dose rate, angular dependence and detector sensitivity and linearity. Also, percentage depth dose, off-axis dose profiles and total scatter ratios were measured and compared against equivalent measurements performed with a stereotactic diode. A Monte Carlo simulation was carried out to estimate the CVD small beam correction factors for a 6 MV photon beam. The small beam correction factors were compared with those obtained from stereotactic diode and ionization chambers in the same irradiation conditions The experimental measurements were performed in 6 and 15 MV photon beams with the following square field sizes: 10 × 10, 5 × 5, 4 × 4, 3 × 3, 2 × 2, 1.5 × 1.5, 1 × 1 and 0.5 × 0.5 cm. The CVD detector showed an excellent signal stability (<0.2%) and linearity, negligible dose rate dependence (<0.2%) and lower response angular dependence. The percentage depth dose and off-axis dose profiles measurements were comparable (within 1%) to the measurements performed with ionization chamber and diode in both conventional and small radiotherapy beams. For the 0.5 × 0.5 cm, the measurements performed with the CVD detector showed a partial volume effect for all the dosimetric quantities measured. The Monte Carlo simulation showed that the small beam correction factors were close to unity (within 1.0%) for field sizes ≥1 cm. The synthetic diamond detector had high linearity, low angular and negligible dose rate dependence, and its response was energy independent within 1% for field sizes from 1.0 to 5.0 cm. This work provides new data showing the performance of the CVD detector compared against a high spatial resolution diode. It also presents a comparison of the CVD small beam correction factors with those of diode and ionization chamber for a 6 MV photon beam.

1 August 2010 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
OGOlivia Amanda García Garduño
Olivia Amanda García Garduño
JLJosé M. Lárraga-Gutiérrez
José M. Lárraga-Gutiérrez
MRMercedes Rodríguez-Villafuerte
Mercedes Rodríguez-Villafuerte
AMArnulfo Martínez-Dávalos
Arnulfo Martínez-Dávalos
MCMiguel A. Celis
Miguel A. Celis

23 June 2008 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
OGOlivia Amanda García Garduño
Olivia Amanda García Garduño
MCMiguel Ángel Celis
Miguel Ángel Celis
JLJosé Manuel Lárraga‐Gutiérrez
José Manuel Lárraga‐Gutiérrez
SMSergio Moreno‐Jiménez
Sergio Moreno‐Jiménez
AMArnulfo Martínez‐Dávalos
Arnulfo Martínez‐Dávalos
MRMercedes Rodríguez‐Villafuerte
Mercedes Rodríguez‐Villafuerte
Micro‐multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation system and requires the use of detectors with high spatial resolution, high sensitivity and practically no energy dependence. In this work the use of GafChromic EBT radiochromic film to measure the basic dosimetric properties of the m3‐mMLC (BrainLAB, Germany) micro‐multileaf collimator system integrated to a 6 MV linear accelerator, is reported. Results show that average values of transmission and leakage radiation areand, respectively. The 80–20% beam penumbra were found to bealong the leaf side (perpendicular to leaf motion) andalong the leaf end (parallel to leaf motion) using square field sizes ranging from 9.1 to 1.8 cm. These measurements are in agreement with values reported in the literature for the same type of mMLC using different radiation detectors.PACS number: 87.56.N‐

21 April 2007 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
MCMiguel Angel Celis-Lopez
Miguel Angel Celis-Lopez
SMS. Moreno-Jiménez
S. Moreno-Jiménez
JLJ. M. Lárraga-Gutiérrez
J. M. Lárraga-Gutiérrez
MVMARIO ALONSO VANEGAS
MARIO ALONSO VANEGAS
OGOlivia Amanda García Garduño
Olivia Amanda García Garduño
MFM. C. Fernández-Gónzalez
M. C. Fernández-Gónzalez

1 March 2018 in Physica Medica
Verified
Journal Article
Open access
JGJosé Manuel Lárraga Gutiérrez
José Manuel Lárraga Gutiérrez
OGOlivia Amanda García Garduño
Olivia Amanda García Garduño
CTCarlos Treviño-Palacios
Carlos Treviño-Palacios
JHJosé Alfredo Herrera-González
José Alfredo Herrera-González
Flatbed scanners are the most frequently used reading instrument for radiochromic film dosimetry because its low cost, high spatial resolution, among other advantages. These scanners use a fluorescent lamp and a CCD array as light source and detector, respectively. Recently, manufacturers of flatbed scanners replaced the fluorescent lamp by light emission diodes (LED) as a light source. The goal of this work is to evaluate the performance of a commercial flatbed scanner with LED based source light for radiochromic film dosimetry. Film read out consistency, response uniformity, film-scanner sensitivity, long term stability and total dose uncertainty was evaluated. In overall, the performance of the LED flatbed scanner is comparable to that of a cold cathode fluorescent lamp (CCFL). There are important spectral differences between LED and CCFL lamps that results in a higher sensitivity of the LED scanner in the green channel. Total dose uncertainty, film response reproducibility and long-term stability of LED scanner are slightly better than those of the CCFL. However, the LED based scanner has a strong non-uniform response, up to 9%, that must be adequately corrected for radiotherapy dosimetry QA. The differences in light emission spectra between LED and CCFL lamps and its potential impact on film-scanner sensitivity suggest that the design of a dedicated flat-bed scanner with LEDs may improve sensitivity and dose uncertainty in radiochromic film dosimetry.