Sule Sahin

Ms. Sule Sahin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2023 in Tomography
Verified
Journal Article
Open access
PDF file
SSSule Sahin
Sule Sahin
XJXiao Ji
Xiao Ji
SAShubhangi Agarwal
Shubhangi Agarwal
ASAvantika Sinha
Avantika Sinha
IMIvina Mali
Ivina Mali
RSRenuka Sriram
Renuka Sriram
Metabolite-specific echo-planar imaging (EPI) sequences with spectral–spatial (spsp) excitation are commonly used in clinical hyperpolarized [1-13C]pyruvate studies because of their speed, efficiency, and flexibility. In contrast, preclinical systems typically rely on slower spectroscopic methods, such as chemical shift imaging (CSI). In this study, a 2D spspEPI sequence was developed for use on a preclinical 3T Bruker system and tested on in vivo mice experiments with patient-derived xenograft renal cell carcinoma (RCC) or prostate cancer tissues implanted in the kidney or liver. Compared to spspEPI sequences, CSI were found to have a broader point spread function via simulations and exhibited signal bleeding between vasculature and tumors in vivo. Parameters for the spspEPI sequence were optimized using simulations and verified with in vivo data. The expected lactate SNR and pharmacokinetic modeling accuracy increased with lower pyruvate flip angles (less than 15°), intermediate lactate flip angles (25° to 40°), and temporal resolution of 3 s. Overall SNR was also higher with coarser spatial resolution (4 mm isotropic vs. 2 mm isotropic). Pharmacokinetic modelling used to fit kPL maps showed results consistent with the previous literature and across different sequences and tumor xenografts. This work describes and justifies the pulse design and parameter choices for preclinical spspEPI hyperpolarized 13C-pyruvate studies and shows superior image quality to CSI.

14 March 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
NDNikhil Deveshwar
Nikhil Deveshwar
ARAbhejit Rajagopal
Abhejit Rajagopal
SSSule Sahin
Sule Sahin
Efrat ShimronEfrat Shimron
Efrat Shimron
PLPeder Larson
Peder Larson
Despite the proliferation of deep learning techniques for accelerated MRI acquisition and enhanced image reconstruction, the construction of large and diverse MRI datasets continues to pose a barrier to effective clinical translation of these technologies. One major challenge is in collecting the MRI raw data (required for image reconstruction) from clinical scanning, as only magnitude images are typically saved and used for clinical assessment and diagnosis. The image phase and multi-channel RF coil information are not retained when magnitude-only images are saved in clinical imaging archives. Additionally, preprocessing used for data in clinical imaging can lead to biased results. While several groups have begun concerted efforts to collect large amounts of MRI raw data, current databases are limited in the diversity of anatomy, pathology, annotations, and acquisition types they contain. To address this, we present a method for synthesizing realistic MR data from magnitude-only data, allowing for the use of diverse data from clinical imaging archives in advanced MRI reconstruction development. Our method uses a conditional GAN-based framework to generate synthetic phase images from input magnitude images. We then applied ESPIRiT to derive RF coil sensitivity maps from fully sampled real data to generate multi-coil data. The synthetic data generation method was evaluated by comparing image reconstruction results from training Variational Networks either with real data or synthetic data. We demonstrate that the Variational Network trained on synthetic MRI data from our method, consisting of GAN-derived synthetic phase and multi-coil information, outperformed Variational Networks trained on data with synthetic phase generated using current state-of-the-art methods. Additionally, we demonstrate that the Variational Networks trained with synthetic k-space data from our method perform comparably to image reconstruction networks trained on undersampled real k-space data.

22 May 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
SSSule Sahin
Sule Sahin
MGMarie Frederikke Garnæs
Marie Frederikke Garnæs
ABAnna Bennett
Anna Bennett
NDNicholas Dwork
Nicholas Dwork
STShuyu Tang
Shuyu Tang
PLPeder Larson
Peder Larson

22 February 2025 in Tomography
Verified
Journal Article
Open access
PDF file
SNSatvik Nayak
Satvik Nayak
Henry SalkeverHenry Salkever
Henry Salkever
EDErnesto Diaz
Ernesto Diaz
ASAvantika Sinha
Avantika Sinha
NDNikhil Deveshwar
Nikhil Deveshwar
RSRenuka Sriram
Renuka Sriram
Background/Objective: Longitudinal in vivo studies of murine xenograft models are widely utilized in oncology to study cancer biology and develop therapies. Magnetic resonance imaging (MRI) of these tumors is an invaluable tool for monitoring tumor growth and characterizing the tumors as well. Methods: In this work, a pipeline for automating the segmentation of xenografts in mouse models was developed. T2-weighted (T2-wt) MRI images from mice implanted with six different prostate cancer patient-derived xenografts (PDX) in the kidneys, liver, and tibia were used. The segmentation pipeline included a slice classifier to identify the slices that had tumors and subsequent training and validation using several U-Net-based segmentation architectures. Multiple combinations of the algorithm and training images for different sites were evaluated for inference quality. Results and Conclusions: The slice classifier network achieved 90% accuracy in identifying slices containing tumors. Among the various segmentation architectures tested, the dense residual recurrent U-Net achieved the highest performance in kidney tumors. When evaluated across the kidneys, tibia, and liver, this architecture performed the best when trained on all data as compared to training on only data from a single site (and inferring on a multi-site tumor images), achieving a Dice score of 0.924 across the test set.

1 January 2018
Verified
Conference Paper
Closed access
PDF file
MVMorris D. Vanegas
Morris D. Vanegas
BZBernhard B. Zimmermann
Bernhard B. Zimmermann
SSSule Sahin
Sule Sahin
SCStefan Carp
Stefan Carp
QFQianqian Fang
Qianqian Fang
We report a mobile-phone based reflectance pulse oximeter for use in resource-poor regions. The developed prototype was validated against a reference device in a breath-holding study.

1 January 2018
Verified
Conference Paper
Closed access
PDF file
XSXin Sun
Xin Sun
SSSule Sahin
Sule Sahin
MVMorris Vanegas
Morris Vanegas
ATAnh Phong Tran
Anh Phong Tran
QFQianqian Fang
Qianqian Fang
We describe a method to create a complex human brain optical phantom using 3D-printed molds and silicone. The phantom contains 3 tissue layers, including scalp, CSF and grey matter with tissue-like optical properties.