Eren C Karsu Asal

Dr. Eren C Karsu Asal

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Radiation Measurements
Verified
Journal Article
Closed access
EAEren C Karsu Asal
Eren C Karsu Asal
Georgios S. PolymerisGeorgios S. Polymeris
Georgios S. Polymeris
GKG. Kitis
G. Kitis

14 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
MTMehmet TASTAN
Mehmet TASTAN
EAEren C Karsu Asal
Eren C Karsu Asal
HGHayrettin Gökozan
Hayrettin Gökozan
The high installation and operational costs of reference-grade air quality monitoring systems have accelerated the widespread adoption of low-cost sensors (LCS). However, their susceptibility to environmental influences, temporal drift, and measurement uncertainty necessitates robust calibration approaches to ensure reliable measurements. Although machine learning (ML)-based calibration methods have been widely investigated, most existing implementations rely on static analytical workflows and require programming expertise, which limits their accessibility for many domain specialists. To simplify and standardize the calibration process for low-cost air quality sensors, this study presents Air Quality Multi-Model Calibration (AQ-MultiCal), an interactive, no-code platform. The platform provides a unified environment for evaluating 14 regression models, performing automated hyperparameter optimization, and conducting comparative performance analysis through an intuitive graphical interface supported by interactive visualization tools. The platform is validated using CO2 measurements collected from January and February 2025. Experimental results indicate that the optimized k-nearest neighbors (kNN) model achieved the best performance, with a coefficient of determination of R2 = 0.990 with low prediction error. These results demonstrate that AQ-MultiCal enables accurate sensor calibration and systematic comparison of ML models while improving the accessibility of ML-based calibration through an open-source platform designed for domain experts without programming expertise.


28 April 2023 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
EAEren C Karsu Asal
Eren C Karsu Asal

9 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
EAEren C Karsu Asal
Eren C Karsu Asal
MTMehmet TASTAN
Mehmet TASTAN
HGHayrettin Gökozan
Hayrettin Gökozan
MEMuge ErelOzcevik
Muge ErelOzcevik
YÖYusuf Özçevik
Yusuf Özçevik
Low-cost sensors (LCSs) are increasingly used in air quality monitoring because of their affordability and scalability; however, their limited accuracy necessitates reliable calibration approaches. Although machine learning (ML)-based calibration methods have shown promising results, direct comparisons of hyperparameter optimization (HPO) strategies remain challenging due to differences in datasets, search spaces, and optimization budgets. In this study, ML models and HPO methods were evaluated within a standardized experimental framework developed on the AQ-MultiCal platform. Grid Search (GS), Random Search (RS), and Bayesian Optimization (BO) were implemented using identical hyperparameter search spaces and equal iteration budgets across both short-term and long-term real-world CO2 datasets obtained from five low-cost NDIR-based sensors. The results showed that tree-based models achieved strong baseline performance, whereas the k-nearest neighbors (kNN) model demonstrated the greatest improvement after optimization. The optimized kNN model reduced the average RMSE from 77.4 ppm to 54.4 ppm for the short-term dataset and from 37.3 ppm to 26.2 ppm for the long-term dataset. Although the HPO methods achieved comparable predictive accuracy, substantial differences were observed in computational cost. The proposed framework enables fair and reproducible comparison of HPO strategies while balancing predictive performance and computational efficiency in real-world sensor calibration applications.

18 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
EAEren C Karsu Asal
Eren C Karsu Asal
MTMehmet TASTAN
Mehmet TASTAN
HGHayrettin Gökozan
Hayrettin Gökozan
Optically stimulated luminescence (OSL) is widely used in radiation dosimetry and luminescence research, creating a continuing need for flexible measurement systems capable of supporting diverse experimental protocols. In this study, LuminaOSL was designed and developed as a modular, automated, computer-controlled research platform for implementing different OSL measurement protocols. The platform integrates programmable LED-based optical stimulation, photomultiplier tube (PMT)-based photon counting, an automated eight-position sample mechanism, microcontroller-based control, and a Python-based user interface within a unified architecture. System performance was evaluated through repeated measurements using beryllium oxide (BeO), low-signal control tests, and CW-OSL and LM-OSL experiments. A cycle-to-cycle coefficient of variation of 0.41% was obtained over successive measurement cycles, with no missing data observed during data acquisition and transfer. BeO measurements yielded monotonically decreasing CW-OSL responses under constant optical stimulation and peak-shaped LM-OSL responses under linearly increasing optical stimulation. These findings indicate that LuminaOSL can support stable and reproducible measurements through the integration of programmable optical stimulation, automated sample handling, and time-controlled photon counting, with potential applicability to radiation dosimetry and smart healthcare engineering research.