Slope fractures play an important role in slope destabilization accidents induced by rainfall, but its influence on seepage field and slope stability is not fully studied, especially under the conditions of soil permeability anisotropy. This study aims to investigate the influence of anisotropic permeability property of soil and fractures on the seepage field and slope stability under rainfall conditions. The surface cracks of the slope are regarded as continuous medium, and the saturated-unsaturated seepage theory is applied to the numerical simulation of the fractured soil slopes with different anisotropic permeability ratios by Geo-studio software. The evolution of seepage field and slope stability under the rainfall conditions are investigated using finite element simulation tool. The simulation results reveal that fractures mainly impact the pressure distribution in the seepage field of the shallow layer of slope, and have little effect on the deep layer. Furthermore, the anisotropic permeability of the soil has a significant effect on the seepage field, safety factor, and fracture action of the slope under rainfall conditions. These findings provide critical insights into slope engineering and management under anisotropic soil conditions.
Earthquakes are often followed by higher-intensity aftershocks, which tend to aggravate the accumulated and more severe damage to building structures. The seismic vulnerability of concrete-filled steel tube (CFST) structures under major aftershocks is more complex. In this paper, a CFST frame and a frame with buckling-restrained braces (BRBs) are studied, and the finite element analysis software Midas 2022 is used to analyze the seismic vulnerability of the two types of structures under main shock and main–aftershock. The results show that the structural vulnerability of the two structures is significantly higher under the main–aftershock sequences than under the main shock alone. Compared with the CFST structure, the structure with BRBs can effectively reduce the structural displacement and the hysteretic energy, decrease the plastic deformation risk of the structural components, and improve the seismic performance. The structure with BRBs can significantly reduce the probability of structural collapse under the main–aftershock sequence and can provide a reliable guarantee of the stability of the building.
Based on the basic control equations of orthotropic anisotropic half‐space under moving harmonic loads, the transfer matrix solution of a single‐layer foundation is derived by introducing the moving coordinate system, Fourier integral transform, and Cayley–Hamilton theorem. The three‐dimensional (3D) dynamic mechanical model of layered orthotropic anisotropic foundation under the rectangular coordinate system is established. The dynamic response of the layered foundation along the depth direction in the frequency domain is derived by using the transfer matrix method, combining boundary conditions, interlayer contact conditions, and continuity conditions. The analytical expressions of the displacements and stresses in the layered foundation are obtained by using Fourier inverse transformation. Based on the derived theoretical method, degradation verification, and corresponding calculation program are prepared for numerical calculation, and numerical example parameter analysis was carried out in combination with the finite element analysis software ABAQUS to study the influence law of the stratification characteristics, load moving speed, load vibration frequency and orthotropic anisotropic properties on the dynamic response of layered foundation. The 3D dynamic characteristics of layered orthotropic anisotropic foundations under the moving load are revealed. The results show that the stratification characteristics of the foundation have a significant effect on the vertical displacement of the surface, and the changes in elastic modulus and shear modulus parameters of the first layer of soil have a greater effect on the displacement dynamic response than that of the subsoil. Within a certain range, the vertical displacement of the foundation surface increases with the increase of load moving speed and decreases with the increase of load vibration frequency. Compared with isotropy, the orthogonal anisotropy of the surface foundation has an obvious influence on the vertical displacement of the foundation surface. In practical engineering, the orthogonal anisotropy of the foundation should be considered in order to obtain more accurate results.
Based on the Kirchhoff thin plate theory, a three-dimensional spatial mechanical model of the subgrade pavement with an infinite elastic plate on the orthotropic saturated foundation in the rectangular coordinate system is established, and the differential equations under a moving harmonic load are derived. The partial differential equations are solved by using coordinate transform and Fourier transform, and the analytical solutions of the dynamic responses of the plate and foundation are obtained. A three-dimensional spatial finite element model of subgrade-pavement is established by ABAQUS finite element software. The correctness of the method is verified by comparing the theoretical solution with the finite element solution. The influence of foundation parameters on plate displacement and vertical normal stress of soil is further studied. The results show that considering the orthogonal anisotropy of saturated soil, the dynamic response of subgrade-pavement slab interaction can be described more accurately.