Qizhi Zhou

Qizhi Zhou


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2023 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
QZQizhi Zhou
Qizhi Zhou
Background: Toxic anterior segment syndrome (TASS) is a non-infectious inflammation that can occur after any anterior segment procedure. This case report presents two relatively rare late-onset TASS cases after V4c implantable collamer lens (ICL) operation. Case presentation: One 25-year-old woman and one 31-year-old woman suddenly had vision loss in monocular for 1 week after biocular V4c ICL operations and with no subjective complaints. They both presented fibrin formation in the anterior chamber such as keratic precipitates and white pus on the surface of the ICL. Fundus examination was normal. After 4 to 5 weeks of topical and oral steroid treatment, visual acuity and fibrin formation in the anterior chamber improved during the follow-up. Conclusions: TASS should be suspected in any patient during the late period following ICL surgery; Once TASS is diagnosed, adequate treatment with intensive steroid therapy can be implemented.

18 July 2023 in International Journal of Ophthalmology
Verified
Journal Article
Closed access
XCXiao Chen
Xiao Chen
LLLi Li
Li Li
JRJing Rao
Jing Rao
YCYue-Xi Chen
Yue-Xi Chen
YGYang Gao
Yang Gao
QZQizhi Zhou
Qizhi Zhou
AIM: To elucidate the safety and visual quality of implantable collamer lens with central hole (ICL V4c) implantation for correcting moderate and high myopia for at least 5y. METHODS: This retrospective study was conducted on 58 patients (114 eyes) who were followed up for at least 5y after ICL V4c implantation. The observation was done before and on 1d, 1mo, 1 and 5y or more after the surgical procedure. The visual acuity, subjective refraction, intraocular pressure, vault, axial length, central hole position, pupil diameter, visual quality, and adverse events were analyzed. The visual quality includes aberration, the modulation transfer function cutoff frequency (MTF cutoff), objective scattering index (OSI), Stroller's ratio (SR), and visual quality questionnaire. RESULTS: The average follow-up period was 69.25±3.80mo (range 60–82mo) and the preoperative spherical equivalent (SE) was -8.66±1.97 D. At 5y after operation, the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was -0.65±0.63 D. The 59.6% of the eyes achieved an uncorrected distance visual acuity of 20/20, 76.3% of the eyes had SE within ±1.0 D at the last visit. The axial length increased by 0.29±0.71 mm 5y after the surgery (t=-3.843, P<0.001). The mean vault at the last follow-up was 510.59±245.61 μm. The central hole was on the temporal side in 80 eyes (84.2%). The visual quality questionnaire showed that 98.2% patients were satisfied with the surgical procedure. Adverse events occurred in 4 eyes (3.5%), including the posttraumatic toric ICL rotation (2 eyes), iris incarceration (1 eye), and posttraumatic ICL displacement (1 eye) at the last follow-up. CONCLUSION: Long-term ICL V4c implantation is safe, effective, and stable for correcting moderate and to high myopia, and the visual quality with patients is excellent and satisfactory, but the progression of axial length still needs attention after surgery.

8 February 2023 in Biomedical Materials
Verified
Journal Article
Closed access
JRJing Rao
Jing Rao
QZQizhi Zhou
Qizhi Zhou
JCJiansu Chen
Jiansu Chen
JGJianing Gu
Jianing Gu
YWYini Wang
Yini Wang
YLYonghuan Liu
Yonghuan Liu
In this study, the drug-loading and antibacterial activity of carbodiimide/N-hydroxysuccinimide (EDC/NHS) crosslinked decellularized lenticules (CDLs) were evaluated. Small incision lenticule extraction derived lenticules were decellularized and modified with crosslinking concentrations of 0.00 (E/L00, non-crosslinked), 0.01 (E/L01), 0.05 (E/L05) and 0.25 mmol (E/L25) EDC per mg lenticules at 5:1 EDC/NHS ratios with non-decellularized non-crosslinked lenticules (NDLs) as controls. NDLs and EDC/NHS CDLs had similar water contents. The light transmittance percentages (400–800 nm) were 91.55 ± 1.16%, 88.68 ± 1.19%, 80.86 ± 1.94%, 85.12 ± 2.42% and 85.62 ± 2.84% for NDLs, E/L00, E/L01, E/L05 and E/L25, respectively (P < 0.01). The EDC/NHS CDLs (diameter: 6.36 ± 0.18 mm; central thickness: 117.31 ± 3.46 μm) were soaked in 3% (wt./vol.) levofloxacin (LEV) solution for 3 h. The drug release concentrations of LEV-impregnated EDC/NHS CDLs were determined by high-performance liquid chromatography. Zone inhibition (ZOI) against Staphylococcus aureus of E/L01, E/L05 and E/L25 were superior to E/L00 CDLs (P < 0.01) and among the different crosslinked groups, E/L05 lenticules produced the largest ZOIs and their drug concentration release over 21 d was the highest. EDC/NHS crosslinking can improve the drug-loading effect and antibacterial activity of decellularized lenticules. LEV-impregnated EDC/NHS CDLs are promising drug delivery carriers.

31 May 2024 in Cell and Tissue Banking
Verified
Journal Article
Closed access
PDF file
QWQin Wang
Qin Wang
YLYonghuan Liu
Yonghuan Liu
YGYang Gao
Yang Gao
MZMing Zhang
Ming Zhang
LYLihong Yang
Lihong Yang
MZMeidong Zhu
Meidong Zhu

25 August 2025 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
LLLi Li
Li Li
QZQizhi Zhou
Qizhi Zhou
To compare the distribution characteristics of corneal biomechanics and tomographic parameters for different corneal diameter (CD) in Chinese patients. A retrospective cohort study of 403 consecutive patients without ectasia who underwent binocular corneal refractive surgery and were followed up for more than 2 years. All patients underwent a preoperative corneal tomography using Pentacam and corneal biomechanics using Corvis-ST. Significant differences were observed in the Stiffness parameter at first applanation (SP-A1), Ambrosio relational thickness to the horizontal profile (ARTh), Belin/Ambrosio enhanced ectasia total deviation index (BAD-D), Corvis Biomechanical Index (CBI), and Tomographic and Biomechanical Index (TBI) indicators among the CD ≤ 11.0 mm, 11.0 mm < CD ≤ 11.5 mm, 11.5 mm < CD < 12.0 mm, and CD ≥ 12.0 mm groups (all P < 0.05). CD was negatively correlated with BAD-D, CBI, and TBI (r = -0.475, -0.269 and − 0.237, all P < 0.05); Multiple linear regression analysis showed that TBI was negatively correlated with CD, SP-A1, and ARTh (R2 = 0.12, p<0.001). CD may correlated with the biomechanical results, where smaller CD is often associated with higher BAD, CBI, and TBI values. CD-specific thresholds for biomechanical indices may reduce overdiagnosis of keratoconus in small corneas.

24 February 2025 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
YGYang Gao
Yang Gao
CLChenxue Liu
Chenxue Liu
LLLi Li
Li Li
QZQizhi Zhou
Qizhi Zhou
The implantable collamer lens (ICL, STAAR Surgical Co.) surgery is popular for its effectiveness and safety, but it carries potential risks. This study presents two unreported cases of hyphema after ICL surgery, highlighting the need for prompt investigation and management of both hyphema and IOP to prevent ocular damage.