Wind turbines emit infrasound and low-frequency noise (ILFN), which can be annoying for people living near wind farms. To assess the acoustic impact of wind turbines on the environment, it is essential to model ILFN propagation during the forecasting stage. This study assesses the effectiveness of three commonly used sound propagation models (ISO 9613-2, CNOSSOS-EU for favourable propagation conditions, Nord2000) in predicting ILFN generated by wind turbines. The performance of these models in modelling ILFN is generally not validated or guaranteed. The analysis covers octave frequency bands ranging from 4 Hz to 250 Hz, and comparisons are made against measurements conducted at a wind farm in Poland. Non-parametric statistical tests were used with a significance level of to determine significant differences between measured and predicted results. The results show that the Nord2000 method provides accurate calculations, while the ISO 9613-2 method can be used for simplified assessments of ILFN generated by wind turbines during the investment preparation phase.
This paper contains a detailed description of the design and validation of a measurement stand for testing the airborne sound insulation of specimens made at a small scale. The stand is comprised of two coupled reverberation rooms in which the geometry represents the full-size reverberation rooms used at the AGH University of Science and Technology at a 1:8 scale. The paper proves that both the scaled measurement stand and the testing methodology conform to the ISO 10140 standards, and that the obtained measurement uncertainty does not exceed the maximum values specified in ISO 12999-1. Moreover, the calculated uncertainty of measurements obtained for the 1:8 scale stand is comparable with the typical uncertainty given in ISO 12999-1 and the uncertainty obtained on the full-scale measurement stand. In connection with the above, the authors have proved that by using the scaled-down measurement stands, one can obtain reliable and repeatable results of measurements of airborne sound insulation.
Measuring noise from wind turbines is a problematic metrological task due to the significant interference caused by the wind, especially in the low-frequency range. In the audible band, especially A-weighted, the impact of interference from wind is considerably less than in the low-frequency and infrasound bands. In the audible band, especially the A-weighted curve, the impact of interference from wind is significantly less than in the low-frequency and infrasound bands. For this reason, methods are still being sought to reduce interference from wind in the lowest frequency bands effectively. Experimental tests within the scope of the work were carried out using several windshields, with a single standard windscreen at 1.5 m and 4 m height, with an additional microphone shield (tent), and on the board with a double windscreen at a ground level according to IEC 61400-11. Experimental verification of a windshield’s effectiveness and impact under real conditions was carried out using a low-frequency noise source, which was the main fan station at the salt mine shaft. This source generates noise with similar spectral characteristics to wind turbines and can operate in windless conditions. This allowed noise measurements to be made without interference from the wind. Signals were recorded in windless and windy conditions at different wind speeds using tested windshields. An effectiveness analysis of the proposed measurement methods was also carried out on the wind farm. Performed research indicates that the best of the tested variants, when measuring wind turbine noise in the low-frequency range, is to place the microphone on the board with a double windscreen according to IEC 61400-11. At wind speeds of less than 5 m/s at 1.5 m above the ground, the shield effectively eliminates disturbances in the band above 4 Hz. Still, as the wind speed increases above 6 m/s, the level of disturbance increases, and its bandwidth in the lowest frequencies expands.
Wind turbines (WT) are a specific type of noise source, with unique characteristics, such as amplitude modulation (AM) and tonality, infrasonic and low frequency (LF) components. The present study investigates the influence of wind turbine infrasound and low frequency noise (LFN) on human well-being. In the between-subjects study design, 129 students performed a cognitive test evaluating attention and filled out questionnaires in three various exposure conditions, including background noise, synthesized LFN (reference noise) and registered WT infrasound (stimulus). No significant differences in test results or in the number of reported post-exposure feelings and ailments in various exposure conditions were found when analyzing them in males and females, separately. However, a significant association between pre-exposure well-being and reported post-exposure complaints was noted and explained by in-depth statistical analysis.
For a long time there is a need in industry of acoustical modeling of rooms. It is necessary for new production room design, machine exchange, renovation or enlargement of production rooms, change in a production profile or acoustical room adaptation for acoustical work conditions improvement. In such cases modeling quality is essential and thanks to uncertainty analysis it is possible to quantitatively estimate the effect that input parameters value variation has on model behavior. The article presents general rules for sound pressure level prediction uncertainty calculation in a room. By partial uncertainty calculation analysis of input parameters influence on uncertainty prediction an effort was taken to find parameters with biggest influence on the prediction process. As an example an industrial production room is presented which was modeled to predict noise level on a work stands after it was expanded.