Seokheun Choi

Prof. Seokheun Choi

Bioelectronics & Microsystems Laboratory (BML), Department of Electrical & Computer Engineering, State University of New York, Binghamton, NY, USA
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
TNThu H Nguyen
Thu H Nguyen
AFArwa Fraiwan
Arwa Fraiwan
Seokheun ChoiSeokheun Choi
Seokheun Choi

1 July 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Seokheun ChoiSeokheun Choi
Seokheun Choi

1 November 2013 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
AFArwa Fraiwan
Arwa Fraiwan
SMSayantika Mukherjee
Sayantika Mukherjee
SSSteven Sundermier
Steven Sundermier
Hyung-Sool LeeHyung-Sool Lee
Hyung-Sool Lee
Seokheun ChoiSeokheun Choi
Seokheun Choi

1 May 2016 in Biotechnology Advances
Verified
Journal Article
Closed access
Seokheun ChoiSeokheun Choi
Seokheun Choi

1 May 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
CFChristopher Fischer
Christopher Fischer
AFArwa Fraiwan
Arwa Fraiwan
Seokheun ChoiSeokheun Choi
Seokheun Choi

31 August 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
ECEunyoung Cho
Eunyoung Cho
MMMaedeh Mohammadifar
Maedeh Mohammadifar
Seokheun ChoiSeokheun Choi
Seokheun Choi
We report a paper-based self-powered sensor patch for prevention and management of exercise-induced hypoglycemia. The article describes the fabrication, in vitro, and in vivo characterization of the sensor for glucose monitoring in human sweat. This wearable, non-invasive, single-use biosensor integrates a vertically stacked, paper-based glucose/oxygen enzymatic fuel cell into a standard Band-Aid adhesive patch. The paper-based device attaches directly to skin, wicks sweat by using capillary forces to a reservoir where chemical energy is converted to electrical energy, and monitors glucose without external power and sophisticated readout instruments. The device utilizes (1) a 3-D paper-based fuel cell configuration, (2) an electrically conducting microfluidic reservoir for a high anode surface area and efficient mass transfer, and (3) a direct electron transfer between glucose oxidase and anodes for enhanced electron discharge properties. The developed sensor shows a high linearity of current at 0.02–1.0 mg/mL glucose centration (R2 = 0.989) with a high sensitivity of 1.35 µA/mM.