Federica Vannetti

Dr. Federica Vannetti

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
TGthe FDG Robotic Rehabilitation Group
the FDG Robotic Rehabilitation Group
Marco GermanottaMarco Germanotta
Marco Germanotta
VGValerio Gower
Valerio Gower
DPDionysia Papadopoulou
Dionysia Papadopoulou
ACArianna Cruciani
Arianna Cruciani
Irene AprileIrene Aprile
Irene Aprile
Background: The majority of stroke survivors experiences significant hand impairments, as weakness and spasticity, with a severe impact on the activity of daily living. To objectively evaluate hand deficits, quantitative measures are needed. The aim of this study is to assess the reliability, the validity and the discriminant ability of the instrumental measures provided by a robotic device for hand rehabilitation, in a sample of patients with subacute stroke.Material and methods: In this study, 120 patients with stroke and 40 controls were enrolled. Clinical evaluation included finger flexion and extension strength (using the Medical Research Council, MRC), finger spasticity (using the Modified Ashworth Scale, MAS) and motor control and dexterity during ADL performance (by means of the Frenchay Arm Test, FAT). Robotic evaluations included finger flexion and extension strength, muscle tone at rest, and instrumented MAS and Modified Tardieu Scale. Subjects were evaluated twice, one day apart, to assess the test-retest reliability of the robotic measures, using the Intraclass Correlation Coefficient (ICC). To estimate the response stability, the standard errors of measurement and the minimum detectable change (MDC) were also calculated. Validity was assessed by analyzing the correlations between the robotic metrics and the clinical scales, using the Spearman’s Correlation Coefficient (r). Finally, we investigated the ability of the robotic measures to distinguish between patients with stroke and healthy subjects, by means of Mann-Whitney U tests.Results: All the investigated measures were able to discriminate patients with stroke from healthy subjects (p < 0.001). Test-retest reliability was found to be excellent for finger strength (in both flexion and extension) and muscle tone, with ICCs higher than 0.9. MDCs were equal to 10.6 N for finger flexion, 3.4 N for finger extension, and 14.3 N for muscle tone. Conversely, test-retest reliability of the spasticity measures was poor. Finally, finger strength (in both flexion and extension) was correlated with the clinical scales (r of about 0.7 with MRC, and about 0.5 with FAT).Discussion: Finger strength (in both flexion and extension) and muscle tone, as provided by a robotic device for hand rehabilitation, are reliable and sensitive measures. Moreover, finger strength is strongly correlated with clinical scales. Changes higher than the obtained MDC in these robotic measures could be considered as clinically relevant and used to assess the effect of a rehabilitation treatment in patients with subacute stroke.

1 November 2015 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
FGFrancesco Giovacchini
Francesco Giovacchini
FVFederica Vannetti
Federica Vannetti
MFMatteo Fantozzi
Matteo Fantozzi
MCMarco Cempini
Marco Cempini
MCMario Cortese
Mario Cortese
NVNicola Vitiello
Nicola Vitiello

31 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LRLuca Ragno
Luca Ragno
Alberto BorboniAlberto Borboni
Alberto Borboni
FVFederica Vannetti
Federica Vannetti
Cinzia AmiciCinzia Amici
Cinzia Amici
NCNicoletta Cusano
Nicoletta Cusano
Cyber-physical or virtual systems or devices that are capable of autonomously interacting with human or non-human agents in real environments are referred to as social robots. The primary areas of application for biomedical technology are nursing homes, hospitals, and private homes for the purpose of providing assistance to the elderly, people with disabilities, children, and medical personnel. This review examines the current state-of-the-art of social robots used in healthcare applications, with a particular emphasis on the technical characteristics and requirements of these different types of systems. Humanoids robots, companion robots, and telepresence robots are the three primary categories of devices that are identified and discussed in this article. The research looks at commercial applications, as well as scientific literature (according to the Scopus Elsevier database), patent analysis (using the Espacenet search engine), and more (searched with Google search engine). A variety of devices are enumerated and categorized, and then our discussion and organization of their respective specifications takes place.

1 June 2017 in European Journal of Internal Medicine
Verified
Journal Article
Closed access
RMR. Molino-Lova
R. Molino-Lova
FSFrancesco Sofi
Francesco Sofi
GPGuido Pasquini
Guido Pasquini
FVFederica Vannetti
Federica Vannetti
SRSilvia Del Ry
Silvia Del Ry
CMClaudio MACCHI
Claudio MACCHI

1 April 2018
Verified
Conference Paper
Closed access
ASAgostino Stilli
Agostino Stilli
ACArianna Cremoni
Arianna Cremoni
MBMatteo Bianchi
Matteo Bianchi
ARAlessandro Ridolfi
Alessandro Ridolfi
FGFilippo Gerii
Filippo Gerii
KAKaspar Althoefer
Kaspar Althoefer
Stroke is one of the leading causes of disability worldwide: post-stroke disabilities affect the upper and lower limbs, significantly undermining a subject's autonomy in the Activities of Daily Living (ADLs). Among post-stroke disabilities, one of the most impairing and widespread conditions is the clenched fist deformity: the subject experiences a permanent contraction of the hand, resulting in a closed hand rest pose. In this paper, the authors propose a novel light-weight inflatable soft exoskeleton device, called the AirExGlove, to deliver high-dosage, adaptive and gradual rehabilitation therapy to patients affected by clenched fist deformity. Our system is lightweight, low-cost, adaptable to any hand size and unobtrusive. The system has been extensively tested to assess the hand-opening range in which it can operate according to the severity of the patient condition, which is typically ranked on the Modified Ashworth Scale (MAS) scale. Experimental analysis demonstrates the suitability of the glove for patients affected by post-stroke muscle spasticity scoring up to 3 out of 4 in the MAS scale. Preliminary testing with clenched-fist patient confirmed a higher level of ergonomics of the system in comparison with rigid-linked robotic systems.

9 July 2011 in Internal and Emergency Medicine
Verified
Journal Article
Closed access
PDF file
RMRaffaele Molino-Lova
Raffaele Molino-Lova
GPGuido Pasquini
Guido Pasquini
FVFederica Vannetti
Federica Vannetti
APAnita Paperini
Anita Paperini
TFTatiana Forconi
Tatiana Forconi
CMClaudio MACCHI
Claudio MACCHI