Claude Inserra

Dr. Claude Inserra

Laboratory of Therapeutic Applications of Ultrasound, INSERM U1032, University of Lyon, Lyon, France

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in International Journal of Rock Mechanics and Mining Sciences
Verified
Journal Article
Closed access
CIClaude Inserra
Claude Inserra
SBShiro Biwa
Shiro Biwa
YCYouqing Chen
Youqing Chen

7 December 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HTHong-Chieh Tsai
Hong-Chieh Tsai
CTChih-Hung Tsai
Chih-Hung Tsai
WCWen-Shiang Chen
Wen-Shiang Chen
CIClaude Inserra
Claude Inserra
KWKuo-Chen Wei
Kuo-Chen Wei
Hao-Li LiuHao-Li Liu
Hao-Li Liu
Focused ultrasound (FUS) with the presence of microbubbles induces blood brain barrier (BBB) opening in targeted areas and facilitates drug delivery. However, recent studies have indicated that FUS-BBB opening with excessive exposure levels may be associated with inflammatory response and cellular/tissue damage. Multiple weekly FUS exposures have been shown to be safe for human subjects. However the effect of more frequent FUS exposures is still unknown. This study examines whether frequent focused ultrasound blood brain barrier opening is associated with aggravated behavioral, histopathologic change or brain tissue damage. Two protocols of focused ultrasound blood brain barrier opening were devised using different microbubble doses (0.15 µl/kg and 0.4 µl/kg). Focused ultrasound exposure at a threshold level of BBB-opening, below-threshold level, or above level for intracerebral hemorrhage were delivered every 2 days. Animal behavioral and physiological changes were examined and recorded. Brain tissue was examined for hemorrhage and apoptosis. Results indicate that frequent exposure of excessive focused ultrasound (1.4 mechanical index) produced minor and short-term behavioral changes despite significant tissue damage, while frequent BBB opening with threshold or below-threshold FUS exposure (0.33–0.8 mechanical index) did not cause behavioral or histological change. Immunofluorescent examination of rat brain tissue indicated that excessive doses of microbubble administration induce an apparent cellular apoptotic response, which may be exacerbated by intracerebral hemorrhage. Experimental results suggest that frequent focused ultrasound blood brain barrier opening with sufficient ultrasound exposure level and a microbubble dose can be safe and pose minimal risk to brain tissue.

22 July 2019 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
SCS. Cleve
S. Cleve
MGM. Guédra
M. Guédra
CMC. Mauger
C. Mauger
CIClaude Inserra
Claude Inserra
PBP. Blanc-Benon
P. Blanc-Benon
While numerous theoretical studies exist on microstreaming around acoustically excited, trapped gas bubbles, experimental approaches have mainly been conducted for bubbles attached to a solid boundary. One of the main difficulties lies in the positional stability of the microbubble. In the present work we trigger surface modes by bubble coalescence, with the advantage of limiting translational instabilities and controlling the orientation of the axisymmetric deformation. Furthermore, streaming is visualised by fluorescent tracer particles. In this way, bubble dynamics and streaming patterns can be studied together. Different types of streaming patterns are observed and correlated to the respective mode number. Besides the mode number, the bubble size and the phase difference between modal components are identified as important parameters in the definition of the pattern type.

1 September 2017 in Ultrasonics Sonochemistry
Verified
Journal Article
Open access
MGMatthieu Guédra
Matthieu Guédra
CCCorentin Cornu
Corentin Cornu
CIClaude Inserra
Claude Inserra
The subharmonic emission of sound coming from the nonlinear response of a bubble population is the most used indicator for stable cavitation. When driven at twice their resonance frequency, bubbles can exhibit subharmonic spherical oscillations if the acoustic pressure amplitude exceeds a threshold value. Although various theoretical derivations exist for the subharmonic emission by free or coated bubbles, they all rest on the single bubble model. In this paper, we propose an analytical expression of the subharmonic threshold for interacting bubbles in a homogeneous, monodisperse cloud. This theory predicts a shift of the subharmonic resonance frequency and a decrease of the corresponding pressure threshold due to the interactions. For a given sonication frequency, these results show that an optimal value of the interaction strength (i.e. the number density of bubbles) can be found for which the subharmonic threshold is minimum, which is consistent with recently published experiments conducted on ultrasound contrast agents.

18 November 2016 in Physical Review E
Verified
Journal Article
Closed access
PDF file
MGMatthieu Guédra
Matthieu Guédra
CIClaude Inserra
Claude Inserra
CMCyril Mauger
Cyril Mauger
BGBruno Gilles
Bruno Gilles
We report observations of strong nonlinear interactions between the spherical, translational, and shape oscillations of micrometer-size bubbles. This is achieved through high-speed recordings of single bubble dynamics driven by amplitude-modulated ultrasound. The features of mode coupling are highlighted through (i) the exponential growth of the parametrically excited mode (n=3) triggered by the spherical oscillations followed by a saturation due to energy transfer towards the translation and even modes, (ii) the excitation of modes well below their parametric pressure threshold, and (iii) clear modification of the breathing mode R(t). These results are compared to recent theories accounting for nonlinear mode coupling, providing predictions in agreement with the observed bubble dynamics.

1 March 2011 in Ultrasonics Sonochemistry
Verified
Journal Article
Closed access
ASAbbas Sabraoui
Abbas Sabraoui
CIClaude Inserra
Claude Inserra
BGBruno Gilles
Bruno Gilles
JBJean-Christophe Béra
Jean-Christophe Béra
JMJean-Louis Mestas
Jean-Louis Mestas