It is very important for holographic optical tweezers (OTs) to develop high-quality phase holograms through calculation by using some computer algorithms, and one of the most commonly used algorithms is the Gerchberg–Saxton (GS) algorithm. An improved GS algorithm is proposed in the paper to further enhance the capacities of holographic OTs, which can improve the calculation efficiencies compared with the traditional GS algorithm. The basic principle of the improved GS algorithm is first introduced, and then theoretical and experimental results are presented. A holographic OT is built by using a spatial light modulator (SLM), and the desired phase that is calculated by the improved GS algorithm is loaded onto the SLM to obtain expected optical traps. For the same sum of squares due to error SSE and fitting coefficient η, the iterative number from using the improved GS algorithm is smaller than that from using traditional GS algorithm, and the iteration speed is faster about 27%. Multi-particle trapping is first achieved, and dynamic multiple-particle rotation is further demonstrated, in which multiple changing hologram images are obtained continuously through the improved GS algorithm. The manipulation speed is faster than that from using the traditional GS algorithm. The iterative speed can be further improved if the computer capacities are further optimized.
This article describes a global structure optimization methodology for microelectromechanical system devices based on a multi-objective elitist genetic algorithm. By integrating a parameterized model with a multi-objective evolutionary framework, the approach can efficiently explore design space and concurrently optimize multiple metrics. A differential capacitive MEMS accelerometer is presented to demonstrate the method. Four key objectives, including resonant frequency, static capacitance, dynamic capacitance, and feedback force, are simultaneously optimized to enhance sensitivity, bandwidth, and closed-loop driving capability. After 25 generations, the algorithm converged to a uniformly distributed Pareto front. The experimental results indicate that, compared with the initial design, the sensitivity-oriented design achieves a 56.1% reduction in static capacitance and an 85.5% improvement in sensitivity. The global multi-objective optimization achieves a normalized hypervolume of 35.8%, notably higher than the local structure optimization, demonstrating its superior design space coverage and trade-off capability. Compared to single-objective optimization, the multi-objective approach offers a superior strategy by avoiding the limitation of overemphasizing resonant frequency at the expense of other metrics, thereby enabling a comprehensive exploration of the design space.
Viscosity measurement is crucial in biomedical research and clinical diagnosis. Currently, rapid and non-contact methods for measuring viscosity remain challenging. We propose a method based on optical coherence tomography for fast, remote assessment of the liquid viscosity. The viscosity of the liquid sample was quantified according to Poiseuille's law, the flow velocity was determined using optical coherence tomography, and the real-time pressure difference was measured by two manometers. Glycerol–water mixtures with various viscosities were tested to assess the accuracy of the optical coherence tomography (OCT) viscosity measurement. Then, blood samples with different levels of hemodilution and hematocrit were measured to validate the feasibility of the OCT method in the blood viscosity measurement. The results indicate that the proposed method can provide rapid, non-contact liquid viscosity measurement. It could significantly impact research on hemodynamics and diagnosis of blood disorders.
The circumferential stress caused by blood flow in blood vessels is closely related to the structural and functional changes of blood vessels. Measuring the circumferential stress of blood vessel models in vitro is an important issue in biomechanics research. A method for measuring the circumferential stress of blood vessels by using fiber gratings was proposed, and a three-dimensional circular blood vessel model integrating fiber gratings was established by using steel needle mold based on microfluidic technology. The relationship between different flow velocities and stress was studied through simulation. The simulation results show that the stress changes linearly with the flow velocity in the range of 8 mm/s~75 mm/s. The circumferential stress generated by fluid flow was measured by fiber Bragg grating sensor. According to the experiment, the relationship between wavelength change of grating and velocity was obtained. When the flow velocity range varies from 8 mm/s to 75 mm/s, the wavelength change caused by velocity is 0.173 nm. The relationship between stress and wavelength change of grating was obtained by simulation experiment. A microfluidic blood vessel model with fiber Bragg grating sensor was proposed and implemented, which provides a new idea for measuring circumferential stress in vitro when blood flows.
In order to measure the cell traction more quickly and intuitively, a measurement method based on Fourier transform was proposed. Firstly, the two-dimensional fast Fourier transform was applied to the image of the micro-column array to obtain its spatial spectrum. Then, one spot in the first-order diffraction spot was selected for the fast Fourier transform to obtain the amplitude distribution of the micro-column array. Finally, the distribution of the offset of the micro-column array could be obtained from the distribution of amplitude mutation and the severity of mutation, and then the distribution of cell force could be obtained by multiplying the stiffness of the micro-column. The influence of frequency point selection, filter window size and offset point size on the experimental results was investigated through simulation experiments. On this basis, the high-power micrograph of cell micro-column was measured. The experimental results show that this method is comparable to the centroid method in terms of the result presentation. The relative error of the maximum cell force measured in each region is within 17.37%, the relative error of the average cell force measured in each region is within 7.93%, and the operation speed is nearly 10 times faster than that of the centroid method.