Nuo Zhang

Nuo Zhang


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Yaoguang WangYaoguang Wang
Yaoguang Wang
DFDawei Fan
Dawei Fan
GZGuanhui Zhao
Guanhui Zhao
JFJinhui Feng
Jinhui Feng
DWDong Wei
Dong Wei
Qin WeiQin Wei
Qin Wei

1 April 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
XLXiaojian Li
Xiaojian Li
DWDan Wu
Dan Wu
HMHongmin Ma
Hongmin Ma
HWHuan Wang
Huan Wang
Yaoguang WangYaoguang Wang
Yaoguang Wang
NZNuo Zhang
Nuo Zhang

22 January 2019 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
JFJinhui Feng
Jinhui Feng
FLFaying Li
Faying Li
XLXiaojian Li
Xiaojian Li
XRXiang Ren
Xiang Ren
DFDawei Fan
Dawei Fan
Qin WeiQin Wei
Qin Wei
In this work, the heterostructures of Au nanoparticles loaded on 3D flower-like α-Fe2O3 (Au NPs/α-Fe2O3) as a platform and core–shell CdSe@CdS quantum dots sensitized graphene oxide (GO/CdSe@CdS QDs) as a signal amplification label were established in an ultrasensitive sandwich-type photoelectrochemical (PEC) immunosensor based on the “signal-on” type amplification method for detection of amyloid β-protein (Aβ). Specifically, the ultrahigh sensitivity of the proposed immunosensor came from two main properties. First, Au NPs/α-Fe2O3 could partially absorb visible-light, which dramatically promotes electron transfer because of the excellent conductivity of Au NPs, and effectively inhibits the electron–hole recombination, thanks to the effect of heterostructures. Second, the signal-on type is based on the signal amplification label of GO/CdSe@CdS QDs which on adequate absorption of visible-light can improve generation of photogenerated electron–hole pairs effectively. Under optimal conditions, the well-prepared PEC immunosensor exhibited a low detection limit of 0.02 pg mL−1 and a wide linear range from 0.06 pg mL−1 to 350 ng mL−1 for Aβ detection. Meanwhile, it also presented good reproducibility, specificity, and stability and might open a new promising pathway for detection of other important biomarkers.

19 March 2024 in Talanta
Verified
Journal Article
Closed access
HWHuan Wang
Huan Wang
YJYue Jia
Yue Jia
TFTao Feng
Tao Feng
BABing An
Bing An
HMHongmin Ma
Hongmin Ma
Qin WeiQin Wei
Qin Wei

10 March 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Guanhui ZhaoGuanhui Zhao
Guanhui Zhao
YWYingying Wang
Yingying Wang
HWHuixin Wang
Huixin Wang
GBGuozhen Bai
Guozhen Bai
NZNuo Zhang
Nuo Zhang
Qin WeiQin Wei
Qin Wei
As an inflammatory marker, procalcitonin (PCT) is more representative than other traditional inflammatory markers. In this work, a highly efficient photoelectrochemical (PEC) immunosensor was constructed based on the photoactive material Bi2S3/Ag2S to realize the sensitive detection of PCT. Bi2S3 was prepared by a hydrothermal method, and Ag2S quantum dots were deposited on the ITO/Bi2S3 surface via in situ reduction. Bi2S3 is a kind of admirable photoelectric semiconductor nanomaterial on account of its moderate bandgap width and low binding rate of photogenerated electron holes, which can effectively convert light energy into electrical energy. Therefore, based on the energy level matching principle of Bi2S3 and Ag2S, a labeled Bi2S3/Ag2S PEC immunosensor was constructed, and the sensitive detection of PCT was successfully established. The linear detection range of the PEC immunosensor was 0.50 pg∙mL−1 to 50 ng∙mL−1, and the minimum detection limit was 0.18 pg∙mL−1. Compared with the traditional PEC strategy, the proposed PEC immunosensor is simple, convenient, and has good anti-interference, sensitivity, and specificity, which could provide a meaningful theoretical basis and reference value for the clinical detection of PCT.