Katia Genovese

Prof. Dr. Katia Genovese


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
KGKatia Genovese
Katia Genovese
YCYuxi Chi
Yuxi Chi
Bing PanBing Pan
Bing Pan
We propose an easy-to-implement yet accurate calibration method for large-scale 3D measurements that makes use of a regular-sized phase target and two planar mirrors. Being insensitive to severe defocus, the phase target is placed as to span a large depth within the field of view (FOV) of each camera for accurate intrinsic calibration. Extrinsic calibration is achieved by placing the phase target in the FOV of a short-range virtual stereo-system generated by the mirrors. Results from 3D shape and deformation measurements demonstrate that the proposed method is capable to operate within a working volume of 3 m × 2 m × 1.8 m with an error < 0.1% of the FOV thus opening to new possibilities for large-scale measurements in mechanical and civil engineering applications.

1 May 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
KGKatia Genovese
Katia Genovese
SLSander Leeflang
Sander Leeflang
Amir A ZadpoorAmir A Zadpoor
Amir A Zadpoor

7 April 2015 in Medical Engineering & Physics
Verified
Journal Article
Closed access
KGKatia Genovese
Katia Genovese
AMAreli Montes
Areli Montes
AMAmalia Martínez
Amalia Martínez
SESam L. Evans
Sam L. Evans
Inverse finite element-based analysis of soft biological tissues is an important tool to investigate their complex mechanical behavior and to develop physical models for medical simulations. Although there have recently been advances in dealing with the computational complexities of modeling biological materials, the collection of a sufficiently dense set of experimental data to properly capture their typically regionally varying properties still remains a critical issue. The aim of this work was to develop and test an optical system that combines 2D-Digital Image Correlation (DIC) and a novel Fringe Projection method with radial sensitivity (RFP) to test soft biological tissues under in vitro indentation. This system has the distinctive capability of using a single camera to retrieve the shape and 3D deformation of the whole upper surface of the indented sample without any blind measurement areas (with exception of the area under the indenter), with nominal depth and in-plane resolution of 0.05 mm and 0.004 mm, respectively. To test and illustrate the capabilities of the developed DIC/RFP system, the in vitro response to indentation of a homogeneous and isotropic latex foam is presented against the response of a slab of porcine ventricular myocardium, a highly in-homogeneous and anisotropic tissue. Our results illustrate the enhanced capabilities of the developed method to capture asymmetry in deformation with respect to standard indentation tests. This feature, together with the possibility of miniaturizing the system into a hand-held probe, makes this method potentially extendable to in vivo settings, alone or in combination with ultrasound measurements.

16 July 2021 in Experimental Mechanics
Verified
Journal Article
Open access
PDF file
KGKatia Genovese
Katia Genovese
PBP. Badel
P. Badel
CCC. Cavinato
C. Cavinato
BPB. Pierrat
B. Pierrat
MBMatthew Bersi
Matthew Bersi
JHJ. D. Humphrey
J. D. Humphrey
Background Digital image correlation (DIC) methods are increasingly used for non-contact optical assessment of geometry and deformation in soft tissue biomechanics, thus providing the full-field strain estimates needed for robust inverse material characterization. Despite the well-known flexibility and ease of use of DIC, issues related to spatial resolution and depth-of-field remain challenging in studies of quasi-cylindrical biological samples such as arteries. Objective After demonstrating that standard surrounding multi-view DIC systems are inappropriate for such usage, we submit that both the optical setup and the data analysis need to be specifically designed with respect to the size of the arterial sample of interest. Accordingly, we propose novel and optimized DIC systems for two distinct ranges of arterial diameters: less than 2.5 mm (murine arteries) and greater than 10 mm (human arteries). Methods We designed, set up, and validated a four-camera panoramic-DIC system for testing murine arteries and a multi-biprism DIC system for testing human arteries. Both systems enable dynamic 360-deg measurements with refraction correction over the entire surface of submerged samples in their native geometries. Results Illustrative results for 3D shape and full-surface deformation fields were obtained for a mouse infrarenal aorta and a latex cylinder of size similar to the human infrarenal aorta. Conclusion Results demonstrated the feasibility and accuracy of both proposed methods in providing quantitative information on the regional behavior of arterial samples tested in vitro under physiologically relevant loading.

17 June 2024 in Optics and Lasers in Engineering
Verified
Journal Article
Open access
KGKatia Genovese
Katia Genovese

1 July 2016 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
KGKatia Genovese
Katia Genovese