Leon von der Emde

Dr. Leon von der Emde


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
LELeon von der Emde
Leon von der Emde
MSMarlene Sassmannshausen
Marlene Sassmannshausen
OMOlivier Morelle
Olivier Morelle
GRGeena Rennen
Geena Rennen
FHFrank G. Holz
Frank G. Holz
TAThomas Ach
Thomas Ach
Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 µm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source bandwidth compared to a conventional OCT device (880 nm central wavelength, 7 µm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in patients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was significantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution.

9 July 2024 in BMJ Open Ophthalmology
Verified
Journal Article
Open access
PDF file
JAJulius Ameln
Julius Ameln
MSMarlene Sassmannshausen
Marlene Sassmannshausen
LELeon von der Emde
Leon von der Emde
ACAlessandra Carmichael-Martins
Alessandra Carmichael-Martins
FHFrank G Holz
Frank G Holz
WHWolf Harmening
Wolf Harmening
Objective: Lesions of incomplete retinal pigment epithelium and outer retinal atrophy (iRORA) are associated with disease progression in intermediate age-related macular degeneration (AMD). However, the corresponding functional impact of these precursor lesions is unknown and needs to be established. Methods and analysis: We present a cross-sectional study of four patients with intermediate AMD employing clinical-grade MAIA (stimulus size: 0.43°, ~125 µm) and adaptive optics scanning light ophthalmoscope (AOSLO, stimulus size 0.07°, ~20 µm) based microperimetry (MP) to assess the specific impact of iRORA lesions on retinal sensitivity. Results: AOSLO imaging showed overall reduced photoreceptor reflectivity and patches of hyporeflective regions at drusen with interspersed hyperreflective foci in iRORA regions. MAIA-MP yielded an average retinal sensitivity loss of -7.3 ±3.1 dB at iRORA lesions compared to the in-eye control. With AOSLO-MP, the corresponding sensitivity loss was -20.1 ±4.8 dB. Conclusion: We demonstrated that iRORA lesions are associated with a severe impairment in retinal sensitivity. Larger cohort studies will be necessary to validate our findings.

1 October 2024 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
MPMaximilian Pfau
Maximilian Pfau
JJJasleen K Jolly
Jasleen K Jolly
JCJason Charng
Jason Charng
LELeon von der Emde
Leon von der Emde
Philipp L. MüllerPhilipp L. Müller
Philipp L. Müller
ZWZhichao Wu
Zhichao Wu
Purpose: The purpose of this study was to provide a large, multi-center normative dataset for the Macular Integrity Assessment (MAIA) microperimeter and compare the goodness-of-fit and prediction interval calibration-error for a panel of hill-of-vision models. Methods: Microperimetry examinations of healthy eyes from five independent study groups and one previously available dataset were included (1137 tests from 531 eyes of 432 participants [223 women and 209 men]). Linear mixed models (LMMs) were fitted to the data to obtain interpretable hill-of-vision models. A panel of regression models to predict normative data was compared using cross-validation with site-wise splits. The mean absolute error (MAE) and miscalibration area (area between the calibration curve and the ideal diagonal) were evaluated as the performance measures. Results: Based on the parameters “participant age,” “eccentricity from the fovea,” “overlap with the central fixation target,” and “eccentricity along the four principal meridians,” a Bayesian mixed model had the lowest MAE (2.13 decibel [dB]; 95% confidence interval [CI] = 1.9–2.36 dB) and miscalibration area (0.13; 95% CI = 0.07–0.19). However, a parsimonious linear model provided a comparable MAE (2.17 dB; 95% CI = 1.93–2.4 dB) and a similar miscalibration area (0.14; 95% CI = 0.08–0.2). Conclusions: Normal variations in visual sensitivity on mesopic microperimetry can be effectively explained by a linear model that includes age and eccentricity. The dataset and a code vignette are provided for estimating normative values across a large range of retinal locations, applicable to customized testing patterns.

Verified
Journal Article
Open access
PDF file
MSMarlene Sassmannshausen
Marlene Sassmannshausen
LSLeyla Sautbaeva
Leyla Sautbaeva
LELeon von der Emde
Leon von der Emde
MVMarc Vaisband
Marc Vaisband
KSKenneth R. Sloan
Kenneth R. Sloan
TAThomas Ach
Thomas Ach
Background: Drusen and drusenoid deposits are a hallmark of age-related macular degeneration (AMD). Nowadays, a multimodal retinal imaging approach enables the detection of these deposits. However, quantitative data on subretinal drusenoid deposits (SDDs) are still missing. Here, we compare the capability of en-face drusen and SDD area detection in eyes with non-exudative AMD using conventional imaging modalities versus Retro mode imaging. We also quantitatively assess the topographic distribution of drusen and SDDs. Methods: In total, 120 eyes of 90 subjects (mean age ± standard deviation = 74.6 ± 8.6 years) were included. Coherent en-face drusen and SDD areas were measured via near-infrared reflectance, green (G-) and blue (B-) fundus autofluorescence (AF), and Retro mode imaging. Drusen phenotypes were classified by correlating en-face drusen areas using structural high-resolution spectral domain optical coherence tomography. The topographic distribution of drusen was analyzed according to a modified ETDRS (Early Treatment of Diabetic Retinopathy Study) grid. Intraclass correlation coefficient (ICC) analysis was applied to determine the inter-reader agreement in the SDD en-face area assessment. Results: The largest coherent en-face drusen area was found using Retro mode imaging with a mean area of 105.2 ± 45.9 mm2 (deviated left mode (DL)) and 105.4 ± 45.5 mm2 (deviated right mode (DR)). The smallest en-face drusen areas were determined by GAF (50.9 ± 42.6 mm2) and BAF imaging (49.1 ± 42.9 mm2) (p < 0.001). The inter-reader agreement for SDD en-face areas ranged from 0.93 (DR) to 0.70 (BAF). The topographic analysis revealed the highest number of SDDs in the superior peripheral retina, whereas sub-retinal pigment epithelium drusen were mostly found in the perifoveal retina. Retro mode imaging further enabled the detection of the earliest SDD stages. Conclusions: Retro mode imaging allows for a detailed detection of drusen phenotypes. While hundreds/thousands of SDDs can be present in one eye, the impact of SDD number or volume on AMD progression still needs to be evaluated. However, this new imaging modality can add important knowledge on drusen development and the pathophysiology of AMD.

18 June 2025 in Survey of Ophthalmology
Verified
Journal Article
Open access
LELeon von der Emde
Leon von der Emde
SPSimon M. Petzinna
Simon M. Petzinna
MHMartina C. Herwig-Carl
Martina C. Herwig-Carl
MAMaike S. Adamson
Maike S. Adamson
CBClaus-Juergen Bauer
Claus-Juergen Bauer
TAThomas Ach
Thomas Ach
Giant cell arteritis (GCA) is an autoimmune disease of medium and large sized vessels. It is the most prevalent form of primary vasculitis in the western world. Vascular inflammation in GCA can lead to vascular occlusion. Severe neuro-ophthalmological complications, such as arteritic anterior ischemic optic neuropathy (AAION), may present with sudden partial or complete vision loss or diplopia. Visual impairment is often refractory to corticosteroid therapy, underscoring the critical importance of early diagnosis. Delayed diagnosis and initiation of high-dose corticosteroids can lead to contralateral eye involvement and bilateral irreversible vision loss. Recent advances in expedited diagnostics have significantly improved outcomes in GCA patients, particularly by reducing ischemic neuro-ophthalmological events. Thus, a key factor has been the introduction of Fast-Track Clinics that have successfully decreased the incidence of permanent blindness in GCA patients. In these clinics, imaging modalities such as vascular ultrasound, magnetic resonance imaging, and positron emission tomography-computed tomography play a critical role in both diagnosis and disease monitoring, enabling timely and accurate intervention. On the therapeutic front, cytokine-specific inhibitors have improved GCA management, enhancing remission rates and reducing glucocorticoid use. Tocilizumab, an IL-6 receptor (IL-6R) inhibitor, has become a cornerstone of GCA treatment; however, since some patients do not respond to IL-6R inhibition, ongoing research is exploring alternative disease-modifying therapies. These new approaches aim to reduce glucocorticoid dependency, mitigate side effects, enhance visual outcomes, and improve patient outcomes, highlighting a shift towards more individualized treatment approaches.

29 April 2024 in BMJ Open Ophthalmology
Verified
Journal Article
Open access
PDF file
LELeon von der Emde
Leon von der Emde
GRGeena C Rennen
Geena C Rennen
MVMarc Vaisband
Marc Vaisband
JHJan Hasenauer
Jan Hasenauer
RLRaffael Liegl
Raffael Liegl
TAThomas Ach
Thomas Ach
Background Retinal imaging, including fundus autofluorescence (FAF), strongly depends on the clearness of the optical media. Lens status is crucial since the ageing lens has both light-blocking and autofluorescence (AF) properties that distort image analysis. Here, we report both lens opacification and AF metrics and the effect on automated image quality assessment. Methods 227 subjects (range: 19–89 years old) received quantitative AF of the lens (LQAF), Scheimpflug, anterior chamber optical coherence tomography as well as blue/green FAF (BAF/GAF), and infrared (IR) imaging. LQAF values, the Pentacam Nucleus Staging score and the relative lens reflectivity were extracted to estimate lens opacification. Mean opinion scores of FAF and IR image quality were compiled by medical readers. A regression model for predicting image quality was developed using a convolutional neural network (CNN). Correlation analysis was conducted to assess the association of lens scores, with retinal image quality derived from human or CNN annotations. Results Retinal image quality was generally high across all imaging modalities (IR (8.25±1.99) >GAF >BAF (6.6±3.13)). CNN image quality prediction was excellent (average mean absolute error (MAE) 0.9). Predictions were comparable to human grading. Overall, LQAF showed the highest correlation with image quality grading criteria for all imaging modalities (eg, Pearson correlation±CI −0.35 (−0.50 to 0.18) for BAF/LQAF). BAF image quality was most vulnerable to an increase in lenticular metrics, while IR (−0.19 (−0.38 to 0.01)) demonstrated the highest resilience. Conclusion The use of CNN-based retinal image quality assessment achieved excellent results. The study highlights the vulnerability of BAF to lenticular remodelling. These results can aid in the development of cut-off values for clinical studies, ensuring reliable data collection for the monitoring of retinal diseases.