Robert Martin

Dr. Robert Martin

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2003
Verified
Conference Paper
Closed access
PDF file
RCRichard A Chamberlin
Richard A Chamberlin
RMRobert Martin
Robert Martin
CMChristopher Louis Martin
Christopher Louis Martin
ASAntony A Stark
Antony A Stark
A submillimeter Fourier Transform Spectrometer of the Martin-Puplett type was constructed and deployed to the geographical South Pole in 2001. The instrument operates from about 300 GHz to almost 2 THz and was used over winter to acquire atmospheric spectra with resolution as fine as 250 MHz. The main motivation for constructing and deploying this FTS was for astronomical site testing, but the obtained spectra can have important secondary uses in atmospheric science and transmission model validation. Some preliminary, low spectral resolution site testing results are presented here.

28 February 2023 in Photonics
Verified
Journal Article
Open access
PDF file
Marija StrojnikMarija Strojnik
Marija Strojnik
BBBeethoven Bravo-Medina
Beethoven Bravo-Medina
RMRobert Martin
Robert Martin
YWYaujen Wang
Yaujen Wang
High-performance megapixel focal plane arrays with small pixels have been widely used in modern optical remote sensing, astronomical, and surveillance instruments. In the prediction models applied in the traditional instrument performance analysis, the image of a point source is assumed to fall on the center of a detector pixel. A geometrical image of a point source in the realistic optical system may actually fall on any position on the detector pixel because the sensor’s line of sight includes pointing errors and jitter. This traditional assumption may lead to an optimistic error, estimated at between 10% and 20%. We present the critical factors that impact the performance estimate in a realistic instrument design based on the prediction for the noise-equivalent power (NEP). They are the optical centroid efficiency (OCE) and the ensquared energy, or more precisely, the energy on the rectangular detector pixel (EOD). We performed the simulation studies for imaging with an optical system with and without a generalized rectangular central obscuration.

10 September 2024 in Photonics
Verified
Journal Article
Open access
PDF file
Marija StrojnikMarija Strojnik
Marija Strojnik
RMRobert Martin
Robert Martin
YWYaujen Wang
Yaujen Wang
We previously proposed that the optical centroid efficiency (OCE) might be a preferred figure-of-merit to the enclosed energy of a rectangular pixel (EOD) for an instrument subject to unpredictable environmental jitter and alignment conditions. Here we follow the same symbols for the corresponding quantities, particularly the width of the pixel as being equal to 2d. Here we analyze the performance of the OCE vs. the EOD for the three Seidel primary aberrations of an optical component: spherical, coma, and astigmatism, plus defocus. We show that the OCE has an approximate U-shape when graphed against the EOD, for the aberrations ranging from 0 to 1.25λ. We conclude that for pixels larger than 2d = 3λF/#, a small pixel will feature better performance when expecting jitter, misalignment, and other environmental and unpredictable conditions. When evaluating the performance of low-aberration instruments in dynamic and unpredictable environments, the choice of the lager pixel 2d = 7λF/# might be advantageous. Its selection will result in the deterioration of image resolution.

1 September 2020 in Annals of Oncology
Verified
Journal Article
Closed access
STShunji Takahashi
Shunji Takahashi
TST. Shimizu
T. Shimizu
TDT. Doi
T. Doi
JLJ.A. Lopez-Vilarino
J.A. Lopez-Vilarino
RMRobert Martin
Robert Martin
AZA. Zeaiter
A. Zeaiter

9 February 2012
Verified
Conference Paper
Closed access
PDF file
CWChristopher C Wilcox
Christopher C Wilcox
MBMichael Baker
Michael Baker
DWDavid V Wick
David V Wick
RRRobert C Romeo
Robert C Romeo
RMRobert Martin
Robert Martin
BBB L Boyce
B L Boyce
Thin-shelled composite mirrors have been recently proposed as both deformable mirrors for aberration correction and as variable radius of curvature mirrors for phase diversity, auto focus, and adaptive optical zoom. The requirements of actuation of a composite mirror far surpass those for MEMS deformable mirrors. This paper will discuss the development of a finite element model for a 0.2 meter carbon fiber reinforced polymer mirror for use as a variable radius of curvature mirror in conjunction with a MEMS deformable mirror for aberration correction.