Amyotrophic Lateral Sclerosis (ALS) is a neurodegenerative disorder, which has complex diagnostic steps. Electrochemical immunoassays may make the diagnosis simpler and faster. Here, we present the detection of ALS-associated neurofilament light chain (Nf-L) protein through an electrochemical impedance immunoassay on reduced graphene oxide (rGO) screen-printed electrodes. The immunoassay was developed in two different media, i.e., buffer and human serum, to compare the effect of the media on their figures of merit and calibration models. The label-free charge transfer resistance (RCT) of the immunoplatform was used as a signal response to develop the calibration models. We found that exposure of the biorecognition layer to human serum improved the impedance response of the biorecognition element with significantly lower relative error. Moreover, the calibration model obtained in the human serum environment has higher sensitivity and a better limit of detection (0.087 ng/mL) than the buffer medium (0.39 ng/mL). The analyses of the ALS patient samples show that concentrations obtained from the buffer-based regression model was higher than the serum-based model. However, a high Pearson correlation (r = 1.00) between the media suggests that concentration in one medium may be useful to predict the concentration in the other medium. Moreover, the Nf-L concentration appears to increase with age in both male and female groups, while overall higher Nf-L was found in the male group than the female group.
A simple, specific, and isocratic reversed phase-high performance liquid chromatography (RP-HPLC) method with UV detection at 293 nm and column Agela Technology, Venosil XBP C18, (Venosil XBP, 4.6mm×250mm, 10µm) was developed and validated for analysis of moxifloxacin hydrochloride (MOXI) in presence of its degradation products. The retention time of the MOXI was found at 9.99 min. A mobile phase consisting of phosphate buffer and methanol (18:7 v/v) at flow rate of 1.3mL/min, at temperature 50°C maintained by using column oven in the study. While 0.1N HCl was used as diluent. The calibration curves were linear with correlation coefficient (R2) of 0.999. The detection and quantification limit were found as 0.029 µg mL-1 and 0.095 µg mL-1 respectively. The method was validated in accordance with International Conference on Harmonization (ICH) guidelines. The proposed method was found sensitive, specific and was successfully applied for the estimation of MOXI in pharmaceutical formulations. Innumerable analytical measurements are made for the estimation of MOXI in pharmaceutical formulations, so the proposed analytical method leads to provision of cost effective by using low-cost diluents and the reagents.