alizee porto

Dr. alizee porto

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PDPierre Deharo
Pierre Deharo
LLLionel Leroux
Lionel Leroux
ATalexis theron
alexis theron
JFJerome Ferrara
Jerome Ferrara
AVAntoine Vaillier
Antoine Vaillier
TCThomas Cuisset
Thomas Cuisset
Background: Transcatheter aortic valve implantation (TAVI) is the preferred treatment for symptomatic severe aortic stenosis (AS) in a majority of patients across all surgical risks. Patients and methods: Paravalvular leak (PVL) and patient–prosthesis mismatch (PPM) are two frequent complications of TAVI. Therefore, based on the large France-TAVI registry, we planned to report the incidence of both complications following TAVI, evaluate their respective risk factors, and study their respective impacts on long-term clinical outcomes, including mortality. Results: We identified 47,494 patients in the database who underwent a TAVI in France between 1 January 2010 and 31 December 2019. Within this population, 17,742 patients had information regarding PPM status (5138 with moderate-to-severe PPM, 29.0%) and 20,878 had information regarding PVL (4056 with PVL ≥ 2, 19.4%). After adjustment, the risk factors for PVL ≥ 2 were a lower body mass index (BMI), a high baseline mean aortic gradient, a higher body surface area, a lower ejection fraction, a smaller diameter of TAVI, and a self-expandable TAVI device, while for moderate-to-severe PPM we identified a younger age, a lower BMI, a larger body surface area, a low aortic annulus area, a low ejection fraction, and a smaller diameter TAVI device (OR 0.85; 95% CI, 0.83–0.86) as predictors. At 6.5 years, PVL ≥ 2 was an independent predictor of mortality and was associated with higher mortality risk. PPM was not associated with increased risk of mortality. Conclusions: Our analysis from the France-TAVI registry showed that both moderate-to-severe PPM and PVL ≥ 2 continue to be frequently observed after the TAVI procedure. Different risk factors, mostly related to the patient’s anatomy and TAVI device selection, for both complications have been identified. Only PVL ≥ 2 was associated with higher mortality during follow-up.

18 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
APalizee porto
alizee porto
VOVirgile Omnes
Virgile Omnes
MBMichel A. Bartoli
Michel A. Bartoli
RARon Azogui
Ron Azogui
NRNoémie Resseguier
Noémie Resseguier
MGMARINE GAUDRY
MARINE GAUDRY
Background After a type A aortic dissection repair, a patent false lumen in the descending aorta is the most common situation encountered, and is a well-known risk factor for aortic growth, reinterventions and mortality. The aim of this study was to analyze the long-term results of residual aortic dissection (RAD) at a high-volume aortic center with prospective follow-up. Methods In this prospective single-center study, all patients operated for type A aortic dissection between January 2017 and December 2022 were included. Patients without postoperative computed tomography scans or during follow-up at our center, and patients without RAD were excluded. The primary endpoint was all-cause mortality during follow-up for patients with RAD. The secondary endpoints were perioperative mortality, rate of distal aneurysmal evolution, location of distal aneurysmal evolution, rate of distal reinterventions, outcomes of distal reinterventions, and aortic-related death during follow-up. Results In total, 200 survivors of RAD comprised the study group. After a mean follow-up of 27.2 months (1–66), eight patients (4.0%) died and 107 (53.5%) had an aneurysmal progression. The rate of distal reintervention was 19.5% (39/200), for malperfusion syndrome in seven cases (3.5%) and aneurysmal evolution in 32 cases (16.0%). Most reinterventions occurred during the first 2 years (82.1%). Twenty-seven patients were treated for an aneurysmal evolution of RAD including aortic arch with hybrid repair in 21 cases and branched aortic arch endoprosthesis in six cases. In the hybrid repair group, there was no death, and the rate of morbidity was 28.6% (6/21) (one minor stroke, one pulmonary complication, one recurrent paralysis with complete recovery and three major bleeding events). In the branched endograft group, there was no death, no stroke, and no paraplegia. There was one case (16.7%) of carotid dissection. Complete aortic remodeling or complete FL thrombosis on the thoracic aorta was found in 18 cases (85.7%) and in five cases (83.3%) in the hybrid and branched endograft groups, respectively. Conclusions: Despite a critical course in most cases of RAD, with a high rate of aneurysmal evolution and reintervention, the long-term mortality rate remains low with a close follow-up and a multidisciplinary management in an expert center.

Verified
Journal Article
Open access
PDF file
JFJerome FERRARA
Jerome FERRARA
ATalexis theron
alexis theron
APalizee porto
alizee porto
PMPierre Morera
Pierre Morera
PLPaul Luporsi
Paul Luporsi
PDPierre Deharo
Pierre Deharo
Prosthesis–patient mismatch (PPM) is associated with worse outcomes following surgical aortic valve replacement (SAVR). PPM has been identified in a significant proportion of TAVR, particularly in patients with small aortic annuli. Our objective was to evaluate the hemodynamic performances of balloon-expandable (BE) (Sapiens 3TM) versus two different self-expandable (SE) (Evolut ProTM, Accurate NeoTM) TAVR devices in patients with small aortic annulus defined by a computed tomography aortic annulus area (AAA) between 330 and 440 mm2. We enrolled 131 consecutive patients corresponding to 76 Sapiens 3 23 mm (58.0%), 26 Evolut Pro (19.9%) and 29 Accurate Neo (22.1%). Mean age was 82.5 ± 7.06 years, 22.9% of patients were male and mean Euroscore was 4.0%. Mean AAA was 374 ± 27 mm2 for Sapiens 3, 383 ± 29 mm2 for Corevalve Evolut Pro and 389 ± 25 mm2 for Accurate Neo. BE devices were associated with significantly higher rates of PPM (39.5%) as compared to SE devices (15.4% for Corevalve Evolut Pro and 6.9% for Accurate Neo) (p < 0.0001). Paravalvular leaks ≥ 2/4 were more often observed in SE devices (15.4% for Corevalve Evolut Pro and 17.2% for Accurate Neo) than in BE devices (2.6%) (p = 0.007). In conclusion, SE TAVR devices did achieve better hemodynamic results despite higher rates of paravalvular leaks. Therefore, SE TAVI devices could be considered as first choice in small aortic anatomy.

3 August 2023 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
APalizee porto
alizee porto
GSGregoire Stolpe
Gregoire Stolpe
RBRita Badaoui
Rita Badaoui
VBVincent Boudouresques
Vincent Boudouresques
CDCornelia Deutsch
Cornelia Deutsch
ATalexis theron
alexis theron
Introduction: The use of an aortic bioprosthesis is on the rise in younger patients with severe aortic stenosis despite the risk of accelerated structural valve degeneration (SVD). In the search for an optimal valve substitute that would not be prone to SVD, the INSPIRIS bioprosthesis represents a promising solution to lowering the risk of SVD. Here, we report the 1-year outcomes of the INSPIRIS RESILIA aortic bioprosthesis in a population of young patients who underwent aortic valve replacement.Methods: In this prospective single-center study, we included all consecutive patients receiving INSPIRIS RESILIA bioprosthesis between June 2017 and July 2021. Patients with isolated severe aortic regurgitation were excluded. Clinical assessment and transthoracic echocardiography were performed preoperatively and at 1 year post-operatively. The primary outcome was overall mortality at one year.Results: A total of 487 patients were included. The mean age was 58.2 ± 11.5 years, 75.2% were men. Most of the interventions were elective, with a mean EuroSCORE II of 4.8 ± 7.9. The valve annulus size in most cases was either 23 mm or 25 mm. Overall mortality at 1-year was 4.1%. At 1-year, 7 patients (1.4%) had a stroke, 4 patients (0.8%) had a myocardial infarction, and 20 patients (4.1%) were hospitalized for congestive heart failure. The Kaplan-Meier estimated survival rates and survival without major adverse cardiac events at 1-year were 96.4% and 96.7%, respectively. At 1-year follow-up, 10 patients (2.1%) had endocarditis and 1 patient (0.2%) had partial prosthetic thrombosis. Pacemaker implantation at 1-year post-operative was necessary in 27 patients (5.5%). Severe patient prosthesis mismatch and severe intra valvular regurgitation were 1.2% and 0.6%, respectively. The Kaplan-Meier estimated survival rates at 1-year of no infective endocarditis preoperative and infective endocarditis preoperative were 97.9 ± 0.7% and 89.5 ± 3.3%, respectively (P < 0.001). Excluding endocarditis-related complication, no structural valve deterioration and no valve failure requiring redo surgery were reported.Conclusion: This is the largest single-center descriptive study of the 1-year outcomes after INSPIRIS RESILIA bioprosthesis implantation. The EDWARDS INSPIRIS RESILIA bioprosthesis provides encouraging clinical outcomes with an excellent 1- year survival rates and good hemodynamic performance. Long-term studies are mandatory to assess valve durability.

Verified
Journal Article
Open access
PDF file
MGMARINE GAUDRY
MARINE GAUDRY
CGCarine Guivier-Curien
Carine Guivier-Curien
ABArnaud Blanchard
Arnaud Blanchard
APalizee porto
alizee porto
LBLaurence Bal
Laurence Bal
VDValerie Deplano
Valerie Deplano
Background: The aim of this study was to evaluate the aortic diameter and volume during the first year after a type A repair to predict the long-term prognosis of a residual aortic dissection (RAD). Methods: All patients treated in our center for an acute type A dissection with a RAD and follow-up > 3 years were included. We defined two groups: group 1 with dissection-related events (defined as an aneurysmal evolution, distal reintervention, or aortic-related death) and group 2 without dissection-related events. The aortic diameters and volume analysis were evaluated on three postoperative CT scans: pre-discharge (T1), 3–6 months (T2) and 1 year (T3). Results: Between 2009 and 2016, 54 patients were included. Following a mean follow-up of 75.4 months (SD 31.5), the rate of dissection-related events was 62.9% (34/54). The total aortic diameters of the descending thoracic aorta were greater in group 1 at T1, T2 and T3, with greater diameters in the FL (p < 0.01). The aortic diameter evolution at 3 months was not predictive of long-term dissection-related events. The total thoracic aortic volume was significantly greater in group 1 at T1 (p < 0.01), T2 (p < 0.01), and T3 (p < 0.01). At 3 months, the increase in the FL volume was significantly greater in group 1 (p < 0.01) and was predictive for long-term dissection-related events. Conclusion: This study shows that an initial CT scan volume analysis coupled with another at 3 months is predictive for the long-term evolution in a RAD. Based on this finding, more aggressive treatment could be given at an earlier stage.

Verified
Journal Article
Open access
PDF file
RARon AZOGUI
Ron AZOGUI
APalizee porto
alizee porto
MCMaxime Castelli
Maxime Castelli
VOVirgile Omnes
Virgile Omnes
Mariangela DE MASIMariangela DE MASI
Mariangela DE MASI
MGMARINE GAUDRY
MARINE GAUDRY
Objectives: Aortic dissection in patients with Marfan and related syndromes (HTAD) is a serious pathology whose treatment by thoracic endovascular repair (TEVAR) is still under debate. The aim of this study was to assess the results of the TEVAR for aortic dissection in patients with HTAD as compared to a young population without HTAD. Methods: The study received the proper ethical oversight. We performed an observational exposed (confirmed HTAD) vs. non-exposed (<65 years old) study of TEVAR-treated patients. The preoperative, 1 year, and last available CT scans were analyzed. The thoracic and abdominal aortic diameters, aortic length, and volumes were measured. The entry tears and false lumen (FL) status were assessed. The demographic, clinical, and anatomic data were collected during the follow-up. Results: Between 2011 and 2021, 17 patients were included in the HTAD group and 22 in the non-HTAD group. At 1 year, the whole aortic volume increased by +21.2% in the HTAD group and by +0.2% the non-HTAD groups, p = 0.005. An increase in the whole aortic volume > 10% was observed in ten cases (58.8%) in the HTAD group and in five cases (22.7%) in the non-HTAD group (p = 0.022). FL thrombosis was achieved in nine cases (52.9%) in the HTAD group vs. twenty (90.9%) cases in the non-HTAD group (p < 0.01). The risk factors for unfavorable anatomical evolution were male gender and the STABILISE technique. With a linear model, we observed a significantly different aortic volume evolution between the two groups (p < 0.01) with the STABILISE technique; this statistical difference was not found in the TEVAR subgroup. In the HTAD patients, there was a significant difference in the total aortic volume evolution progression between the patients treated with the STABILISE technique and the patients treated with TEVAR (+160.1 ± 52.3% vs. +47 ± 22.5%, p < 0.01 and +189.5 ± 92.5% vs. +58.6 ± 34.8%, p < 0.01 at 1 year and at the end of follow-up, respectively). Conclusions: TEVAR in the HTAD patients seemed to be associated with poorer anatomical outcomes at 1 year. This result was strongly related to the STABILISE technique which should be considered with care in these specific patients.