Mauro Sergio Braga

Dr. Mauro Sergio Braga

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MBMauro Sergio Braga
Mauro Sergio Braga
RJRuth F. V. V. Jaimes
Ruth F. V. V. Jaimes
WBWalter Borysow
Walter Borysow
OGOsmar Gomes
Osmar Gomes
WSWalter Salcedo
Walter Salcedo
This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView®). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution.

13 June 2017 in Preprints.org
Verified
Preprint
Open access
MBMauro Sergio Braga
Mauro Sergio Braga
RJRuth F. V. V. Jaimes
Ruth F. V. V. Jaimes
WBWalter Borysow
Walter Borysow
OGOsmar F. Gomes
Osmar F. Gomes
WSWalter J. Salcedo
Walter J. Salcedo
In the present work, a portable device system applied in the detection and classification of different metallic ions was proposed and developed, aiming at its application in the monitoring of hydrological systems like rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using Optoelectronic Multispectral sensors was fully integrated in the embedded hardware FPGA technology and software based on virtual Instrumentation (NI LabView ®). The system was used as a colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN) as an indicator and the results obtained together with the signal processing and pattern analysis using the method of the linear discriminant analysis, allowed to obtain excellent results in detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance in relation to those obtained from the UV-VIS spectrometers of high spectral resolution.

1 August 2017
Verified
Conference Paper
Closed access
FOFatima C. de Oliveira
Fatima C. de Oliveira
MBMauro Sergio Braga
Mauro Sergio Braga
MBMarcella P. G. Baltazar
Marcella P. G. Baltazar
WSWalter Salcedo
Walter Salcedo
HCHipolito A. Arredondo Champi
Hipolito A. Arredondo Champi
The real time monitoring of biological microorganism growth dynamics without enter any interference is a challenging problems of nowadays. The present work report a portable multispectral system for monitoring the bacterial microorganism growth dynamics. The portable multispectral system proposed in this work is based in the optoelectronic integrated photodetector and the acquisition, control and processing of the signals based on FPGA technology, with hardware manufactured by National Instruments, NI model myRIO-1900. The results obtained with this system showed to have the same performance to the commercial biophotometer bench system.

4 September 2009 in ECS Transactions
Verified
Journal Article
Closed access
PDF file
MBMauro Sergio Braga
Mauro Sergio Braga
KMKeth R. Maciel de Matos
Keth R. Maciel de Matos
DSDaniela S. Santos
Daniela S. Santos
FRFrancisco J. Ramirez-Fernandez
Francisco J. Ramirez-Fernandez
WSWalter Salcedo
Walter Salcedo
This paper presents an analysis of the performance of a Pd-MOS structure with respect to their sensitivity to hydrogenated gases. Assays using an experimental arrangement of the scanning light pulse technique (SLPT) were carried out. This arrangement allowed the chemical images patterns generation that show the sensitivity of the device to different gas composition, which the sensor was exposed.

13 July 2026 in Sensors
Verified
Journal Article
Open access
PDF file
EBEdmilson Roberto Braga
Edmilson Roberto Braga
RJRoberto Márcio Braga Júnior
Roberto Márcio Braga Júnior
MBMauro Sergio Braga
Mauro Sergio Braga
JCJanete Cerutti
Janete Cerutti
WSWalter Salcedo
Walter Salcedo
This study reports the development of a portable multispectral optoelectronic system for automated thyroid cancer detection in immunohistochemically stained histological slides. The platform integrates a 14-band AS7343 multispectral sensor, a dual-fiber optical setup operating in transreflectance geometry, and a two-dimensional scanning subsystem for spatially resolved acquisition. Data acquisition and management were implemented on a Raspberry Pi using Python, Flask, React 19.1.0, Redis, and SocketIO for control, visualization, and real-time updates. A standardized Dark–White–Sample protocol was adopted for baseline correction and the generation of multispectral cubes organized by spatial position and spectral band. The dataset comprised 29 patients, 84 FFPE biomarker-stained histological sections, and 66,510 original point-by-point multispectral measurements. Spectral patterns associated with malignant and non-malignant thyroid samples were analyzed using Linear Discriminant Analysis (LDA), Support Vector Machine with radial basis function kernel (SVM-RBF), and Multilayer Perceptron (MLP). All metrics were evaluated on an independent slide-level test set. LDA achieved 86.8% sensitivity, 95.9% specificity, and 91.0% accuracy. SVM-RBF and MLP achieved accuracies of 90.8% and 90.4%, respectively. Macro-averaged AUC-ROC values were 0.836, 0.865, and 0.761, respectively. These findings support the system as a portable proof-of-concept platform for computer-aided thyroid pathology.

1 January 2024
Verified
Conference Paper
Open access
PDF file
LSLuis Henrique Franco de Sousa
Luis Henrique Franco de Sousa
MBMauro Sergio Braga
Mauro Sergio Braga
Ao longo das últimas décadas, a agricultura tem passado por uma significativa transformação impulsionada pela incorporação de avanços tecnológicos. Nesse cenário, os sensores ópticos multiespectrais emergem como ferramentas cruciais, desempenhando um papel fundamental na otimização dos processos agrícolas. O objetivo principal deste trabalho é desenvolver uma tecnologia que utilize esses sensores para a leitura de sinais ópticos, obtidos pela reflectância de uma fonte de luz branca (LED) e pela resposta fluorescente do mesmo sensor a partir da excitação luminosa de um laser azul (450nm), incidida sobre a superfície de folhas de espécies vegetais e correlacionem a concentração de umidade, nutrientes ou fertilizantes no solo, nos quais essas plantas estejam inseridas, em substituição aos tradicionais métodos realizados pela observação humana. Os sensores ópticos multiespectrais são destacados pela sua sensibilidade, facilidade de operação, baixo custo e possibilidade de integração em redes de sensores sincronizados em IoT (Internet of Things) para monitoramento em tempo real e à distância. A metodologia adotada utiliza o método de reflectância e fluorescência, baseados em sensor óptico multiespectral modelo AS7341 evk reflection da empresa AMS. Foram utilizadas em ambos os ensaios, de 96 horas (quatro dias), duas mudas de plantas (Impatiens parviflora), sendo uma irrigada diariamente e outra não. As folhas foram levemente pressionadas pelo sensor para a leitura de 10 medidas de reflectância ou fluorescência. Para a aquisição de dados, foi utilizado o software AS7341 Demo, da própria empresa AMS; consequentemente, os dados eram salvos em um banco de dados feito no Excel e eram plotados os gráficos de suas respectivas análises. No primeiro ensaio, pelo método de reflectância por um LED de luz branca (sunlike), o comportamento óptico ao estresse hídrico foi analisado e os resultados foram obtidos, destacando variações de intensidade entre os comprimentos de onda de 500 nm e 700 nm, que correspondem aos comprimentos de onda de absorção da molécula de clorofila. Após os relevantes resultados do primeiro ensaio, foi possível realizar as análises de concentrações de clorofila pela resposta da fluorescência das folhas, quando realizado a excitação luminosa do laser de 450nm, obtendo uma análise comparativa entre os métodos. Como conclusão, os métodos utilizados nos ensaios permitiram observar alterações tanto na absorção óptica quanto nas respostas fotoluminescentes, sendo possível obter a validação da estratégia de quantificação de umidade no solo pela resposta de estresse hídrico nas folhas, sugerindo a otimização de processos automatizados em sistemas de irrigação. Este estudo contribui para o avanço da agricultura de precisão, oferecendo uma abordagem tecnológica promissora para a avaliação de umidade e nutrientes em plantas.