David Kwartowitz

Dr. David Kwartowitz


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2015 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
LBLane B. Bailey
Lane B. Bailey
ESEllen Shanley
Ellen Shanley
RHRichard Hawkins
Richard Hawkins
PBPaul F. Beattie
Paul F. Beattie
SFStacy Fritz
Stacy Fritz
CTCharles A. Thigpen
Charles A. Thigpen
Shoulder range of motion (ROM) deficits have been identified as injury risk factors among baseball athletes. Despite the knowledge surrounding these risk factors, there is a lack of consensus regarding the specific tissues responsible for these deficits in ROM. The purpose of this study was to elucidate the primary mechanisms of posterior shoulder tightness (capsular, musculotendinous, bony) by examining the tissue responses that occur with the application of an acute intervention in baseball players with ROM deficits. The hypothesis was that posterior rotator cuff stiffness, not glenohumeral joint mobility, would be primarily responsible for ROM gains observed within an acute treatment setting. Controlled laboratory study. Through use of ultrasound elastography, electromagnetic motion analysis, and ultrasound imaging, posterior rotator cuff stiffness, glenohumeral joint translation, and humeral torsion were examined in 60 asymptomatic baseball players (age, mean ± SD, 19 ± 2 years) with shoulder ROM deficits. Tissue mechanisms were examined concurrently, with the ROM gains elicited by an acute application of instrument-assisted soft tissue mobilization plus self-stretching (n = 30) versus self-stretching only (n = 30). Separate 3-way analyses of variance (group × arm × time) and linear regression analyses were used to determine the treatment effects and relationships between tissue mechanisms and ROM gains. ROM gains were associated with decreases in rotator cuff stiffness (internal rotation: r = 0.35, P = .034; horizontal adduction: r = 0.44, P = .008) and increased humeral retrotorsion (internal rotation: r = −0.35, P = .034), not joint translation (P > .05). Players receiving instrument-assisted soft tissue mobilization plus stretching displayed greater shoulder ROM gains (internal rotation, +5° ± 2° [P = .010]; total arc of motion, +8° ± 6° [P = .010]; horizontal adduction, +7° ± 2° [P = .004]; and decreased posterior rotator cuff stiffness, −0.2 ± 0.3 kPa [P = .050]) compared with players receiving self-stretching alone. Decreases in rotator cuff stiffness were associated with acute ROM gains in baseball players. The study results show that changes in rotator cuff stiffness, not glenohumeral joint mobility or humeral torsion, are most likely associated with the ROM deficits observed in adolescent baseball players. Reducing rotator cuff stiffness may be beneficial in improving the ROM deficits associated with injury risk in overhead athletes.

11 October 2006 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
DKDavid Kwartowitz
David Kwartowitz
SHS. Duke Herrell
S. Duke Herrell
RGRobert L. Galloway
Robert L. Galloway

1 February 2009 in Journal of Urology
Verified
Journal Article
Closed access
SHStanley D. Herrell
Stanley D. Herrell
DKDavid Kwartowitz
David Kwartowitz
PMPaul M. Milhoua
Paul M. Milhoua
RGRobert L. Galloway
Robert L. Galloway
Navigation for current robotic assisted surgical techniques is primarily accomplished through a stereo pair of laparoscopic camera images. These images provide standard optical visualization of the surface but provide no subsurface information. Image guidance methods allow the visualization of subsurface information to determine the current position in relationship to that of tracked tools. A robotic image guided surgical system was designed and implemented based on our previous laboratory studies. A series of experiments using tissue mimicking phantoms with injected target lesions was performed. The surgeon was asked to resect "tumor" tissue with and without the augmentation of image guidance using the da Vinci robotic surgical system. Resections were performed and compared to an ideal resection based on the radius of the tumor measured from preoperative computerized tomography. A quantity called the resection ratio, that is the ratio of resected tissue compared to the ideal resection, was calculated for each of 13 trials and compared. The mean +/- SD resection ratio of procedures augmented with image guidance was smaller than that of procedures without image guidance (3.26 +/- 1.38 vs 9.01 +/- 1.81, p <0.01). Additionally, procedures using image guidance were shorter (average 8 vs 13 minutes). It was demonstrated that there is a benefit from the augmentation of laparoscopic video with updated preoperative images. Incorporating our image guided system into the da Vinci robotic system improved overall tissue resection, as measured by our metric. Adding image guidance to the da Vinci robotic surgery system may result in the potential for improvements such as the decreased removal of benign tissue while maintaining an appropriate surgical margin.

18 February 2007 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
DKDavid Kwartowitz
David Kwartowitz
SHS. Duke Herrell
S. Duke Herrell
RGRobert L. Galloway
Robert L. Galloway

19 March 2009 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
DKDavid Kwartowitz
David Kwartowitz
MMMichael I. Miga
Michael I. Miga
SHS. Duke Herrell
S. Duke Herrell
RGRobert L. Galloway
Robert L. Galloway

4 March 2010
Verified
Conference Paper
Closed access
PDF file
DKDavid Kwartowitz
David Kwartowitz
MRMarayam E. Rettmann
Marayam E. Rettmann
DIDavid R. Holmes Iii
David R. Holmes Iii
RRRichard A. Robb
Richard A. Robb
With the increased use and development of image-guided surgical applications, there is a need for methods of analysis of the accuracy and precision of the components which compose these systems. One primary component of an image-guided surgery system is the position tracking system which allows for the localization of a tool within the surgical field and provides information which is translated back to the images. Previously much work has been done in characterizing these systems for spatial accuracy and precision. Much of this previous work examines single tracking systems or modalities. We have devised a method which allows for the characterization of a novel tracking system independent of modality and location. We describe the development of a phantom system which allows for rapid design and creation of surfaces with different geometries. We have also demonstrated a method of analysis of the data generated by this phantom system, and used it to compare Biosense-Webster's CartoXPTM, and Northern Digital's AuroraTMmagnetic trackers. We have determined that the accuracy and precision of the CartoXP was best, followed closely by the Aurora's dome volume, then the Aurora's cube volume. The mean accuracy for all systems was better than 3mm and decays with distance from the field generator.