Hyungmin Kim

Dr. Hyungmin Kim

Korea Institute of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
WLWonhye Lee
Wonhye Lee
Hyungmin KimHyungmin Kim
Hyungmin Kim
YJYujin Jung
Yujin Jung
ISIn-Uk Song
In-Uk Song
YCYong An Chung
Yong An Chung
SYSeung-Schik Yoo
Seung-Schik Yoo
Focused ultrasound (FUS) has recently been investigated as a new mode of non-invasive brain stimulation, which offers exquisite spatial resolution and depth control. We report on the elicitation of explicit somatosensory sensations as well as accompanying evoked electroencephalographic (EEG) potentials induced by FUS stimulation of the human somatosensory cortex. As guided by individual-specific neuroimage data, FUS was transcranially delivered to the hand somatosensory cortex among healthy volunteers. The sonication elicited transient tactile sensations on the hand area contralateral to the sonicated hemisphere, with anatomical specificity of up to a finger, while EEG recordings revealed the elicitation of sonication-specific evoked potentials. Retrospective numerical simulation of the acoustic propagation through the skull showed that a threshold of acoustic intensity may exist for successful cortical stimulation. The neurological and neuroradiological assessment before and after the sonication, along with strict safety considerations through the individual-specific estimation of effective acoustic intensityin situand thermal effects, showed promising initial safety profile; however, equal/more rigorous precautionary procedures are advised for future studies. The transient and localized stimulation of the brain using image-guided transcranial FUS may serve as a novel tool for the non-invasive assessment and modification of region-specific brain function.

1 September 2014 in Brain Stimulation
Verified
Journal Article
Closed access
Hyungmin KimHyungmin Kim
Hyungmin Kim
ACAlan Chiu
Alan Chiu
SLStephanie D. Lee
Stephanie D. Lee
KFKrisztina Fischer
Krisztina Fischer
SYSeung-Schik Yoo
Seung-Schik Yoo

1 February 2016 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
WLWonhye Lee
Wonhye Lee
SLStephanie D. Lee
Stephanie D. Lee
MPMichael Y. Park
Michael Y. Park
LFLori Foley
Lori Foley
EPErin Purcell-Estabrook
Erin Purcell-Estabrook
SYSeung-Schik Yoo
Seung-Schik Yoo

9 January 2017 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
HBHongchae Baek
Hongchae Baek
KPKi Joo Pahk
Ki Joo Pahk
Hyungmin KimHyungmin Kim
Hyungmin Kim

4 March 2015 in NeuroReport
Verified
Journal Article
Closed access
Hyungmin KimHyungmin Kim
Hyungmin Kim
MPMichael Y. Park
Michael Y. Park
SLStephanie D. Lee
Stephanie D. Lee
WLWonhye Lee
Wonhye Lee
ACAlan Chiu
Alan Chiu
SYSeung-Schik Yoo
Seung-Schik Yoo
We investigated the use of pulsed low-intensity focused ultrasound (FUS) to suppress the visual neural response induced by light stimulation in rodents. FUS was administered transcranially to the rat visual cortex using different acoustic intensities and pulsing duty cycles. The visual-evoked potentials (VEPs) generated by an external strobe light stimulation were measured three times before, once during, and five times after the sonication. The VEP magnitude was suppressed during the sonication using a 5% duty cycle (pulse-repetition frequency of 100 Hz) and a spatial-peak pulse-average acoustic intensity of 3 W/cm2; however, this suppressive effect was not present when a lower acoustic intensity and duty cycle were used. The application of a higher intensity and duty cycle resulted in a slight elevation in VEP magnitude, which suggested excitatory neuromodulation. Our findings demonstrate that the application of pulsed FUS to the region-specific brain area not only suppresses its excitability, but can also enhance the excitability depending on the acoustic intensity and the rate of energy deposition. This bimodal feature of FUS-mediated neuromodulation, which has been predicted by numerical models on neural membrane capacitance change by the external acoustic pressure waves, suggests its versatility for neurotherapeutic applications.

1 October 2010 in Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
STScott Tucker
Scott Tucker
LCLucia Helena Soares Cevidanes
Lucia Helena Soares Cevidanes
MSMartin Styner
Martin Styner
Hyungmin KimHyungmin Kim
Hyungmin Kim
MRMauricio Reyes
Mauricio Reyes
TTTimothy Turvey
Timothy Turvey