Kian Kadan-Jamal

Kian Kadan-Jamal


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
KKKian Kadan-Jamal
Kian Kadan-Jamal
MSMarios Sophocleous
Marios Sophocleous
AJAakash Jog
Aakash Jog
DDDayananda Desagani
Dayananda Desagani
OTOrian Teig-Sussholz
Orian Teig-Sussholz
YSYosi Shacham-Diamand
Yosi Shacham-Diamand

2 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
TDTali Dotan
Tali Dotan
AJAakash Jog
Aakash Jog
KKKian Kadan-Jamal
Kian Kadan-Jamal
Adi AvniAdi Avni
Adi Avni
Yosi ShachamYosi Shacham
Yosi Shacham
This work presents an in vivo stem-mounted sensor for Nicotiana tabacum plants and an in situ cell suspension sensor for Solanum lycopersicum cells. Stem-mounted sensors are mechanically stable and less sensitive to plant and air movements than the previously demonstrated leaf-mounted sensors. Interdigitated-electrode-arrays with a dual working electrode configuration were used with an auxiliary electrode and an Ag/AgCl quasi-reference electrode. Signal amplification by redox cycling is demonstrated for a plant-based sensor responding to enzyme expression induced by different cues in the plants. Functional biosensing is demonstrated, first for constitutive enzyme expression and later, for heat-shock-induced enzyme expression in plants. In the cell suspension with redox cycling, positive detection of the enzyme β-glucuronidase (GUS) was observed within a few minutes after applying the substrate (pNPG, 4-Nitrophenyl β-D-glucopyranoside), following redox reactions of the product (p-nitrophenol (pNP)). It is assumed that the initial reaction is the irreversible reduction of pNP to p-hydroxylaminophenol. Next, it can be either oxidized to p-nitrosophenol or dehydrated and oxidized to aminophenol. Both last reactions are reversible and can be used for redox cycling. The dual-electrode redox-cycling electrochemical signal was an order of magnitude larger than that of conventional single-working electrode transducers. A simple model for the gain is presented, predicting that an even larger gain is possible for sub-micron electrodes. In summary, this work demonstrates, for the first time, a redox cycling-based in vivo plant sensor, where diffusion-based amplification occurs inside a tobacco plant’s tissue. The technique can be applied to other plants as well as to medical and environmental monitoring systems.

1 January 2021 in MethodsX
Verified
Journal Article
Open access
KKKian Kadan-Jamal
Kian Kadan-Jamal
MSMarios Sophocleous
Marios Sophocleous
AJAakash Jog
Aakash Jog
DDDayananda Desagani
Dayananda Desagani
OTOrian Teig-Sussholz
Orian Teig-Sussholz
Yosi ShachamYosi Shacham
Yosi Shacham
Electrical impedance spectroscopy was performed on suspensions of plant cells in aqueous buffer media over a wide frequency range of 4 Hz to 20 GHz. Custom probes were designed, manufactured, and used for these investigations. Experiments were performed with a custom-made parallel plate probe and impedance analysers in the low-frequency range (4 Hz to 5 MHz), with a custom-made coaxial airline probe and a vector network analyser in the mid-frequency range (100 kHz to 3 GHz), and with a commercial open-ended probe and a vector network analyser in the high-frequency range (200 MHz to 20 GHz). The impedance data acquired were processed in order to eliminate the effects of parasitics and compensate for geometrical differences between the three probes. Following this, the data were fitted to a unified model consisting of the Randles and Debye models. The data were also normalized to a reference measurement, in order to accentuate the effects of cell concentration on the impedance of the suspensions.•The methodology allows for impedance spectroscopy of cell suspensions over a wide frequency range spanning 10 orders of magnitude.•It allows for compensation of parasitics and of geometrical variations between probes, using mathematical techniques

29 September 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KKKian Kadan-Jamal
Kian Kadan-Jamal
AJAakash Jog
Aakash Jog
MSMarios Sophocleous
Marios Sophocleous
JGJulius Georgiou
Julius Georgiou
AAAdi Avni
Adi Avni
YSYosi Shacham-Diamand
Yosi Shacham-Diamand
An improved approach for comparative study of plant cells for long term and continuous monitoring using electrical impedance spectroscopy is demonstrated for tomato and tobacco plant cells (MSK8 and BY2) in suspensions. This approach is based on the locations and magnitudes of defining features in the impedance spectra of the recently reported unified equivalent circuit model. The ultra-wide range (4 Hz to 20 GHz) impedance spectra of the cell lines were measured using custom probes, and were analyzed using the unified equivalent circuit model, highlighting significant negative phase peaks in the ~ 1 kHz to ~ 10 MHz range. These peaks differ between the tomato and tobacco cells, and since they can be easily defined, they can potentially be used as the signal for differentiating between different cell cultures or monitoring them over time. These findings were further analysed, showing that ratios relating the resistances of the media and the resistance of the cells define the sensitivity of the method, thus affecting its selectivity. It was further shown that cell agglomeration is also an important factor in the impedance modeling in addition to the overall cell concentration. These results can be used for optimizing and calibrating electrical impedance spectroscopy-based sensors for long term monitoring of cell lines in suspension for a given specific cell and media types.