Md. Hasan Ali

Dr. Md. Hasan Ali

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in Energy
Verified
Journal Article
Closed access
NPNahyan Ahnaf Pratik
Nahyan Ahnaf Pratik
MAMd. Hasan Ali
Md. Hasan Ali
NLNafisa Lubaba
Nafisa Lubaba
NHNahid Hasan
Nahid Hasan
ASAsaduzzaman
Asaduzzaman
MAMiyara Akio
Miyara Akio

13 October 2017 in Resources
Verified
Journal Article
Open access
PDF file
MAMd. Hasan Ali
Md. Hasan Ali
KKKeishi Kariya
Keishi Kariya
MAMiyara Akio
Miyara Akio
This paper highlights the thermal performance of reclined (parallel to ground surface) and standing (perpendicular to ground surface) slinky horizontal ground heat exchangers (HGHEs) with different water mass flow rates in the heating mode of continuous and intermittent operations. A copper tube with an outer surface protected with low-density polyethylene was selected as the tube material of the ground heat exchanger. Effects on ground temperature around the reclined slinky HGHE due to heat extraction and the effect of variation of ground temperatures on reclined HGHE performance are discussed. A higher heat exchange rate was experienced in standing HGHE than in reclined HGHE. The standing HGHE was affected by deeper ground temperature and also a greater amount of backfilled sand in standing HGHE (4.20 m3) than reclined HGHE (1.58 m3), which has higher thermal conductivity than site soil. For mass flow rate of 1 L/min with inlet water temperature 7 °C, the 4-day average heat extraction rates increased 45.3% and 127.3%, respectively, when the initial average ground temperatures at 1.5 m depth around reclined HGHE increased from 10.4 °C to 11.7 °C and 10.4 °C to 13.7 °C. In the case of intermittent operation, which boosted the thermal performance, a short time interval of intermittent operation is better than a long time interval of intermittent operation. Furthermore, from the viewpoint of power consumption by the circulating pump, the intermittent operation is more efficient than continuous operation.

12 October 2023 in International Journal of Thermofluids
Verified
Journal Article
Open access
SPShuvo Paul
Shuvo Paul
NLNafisa Lubaba
Nafisa Lubaba
NPNahyan Ahnaf Pratik
Nahyan Ahnaf Pratik
MAMd. Hasan Ali
Md. Hasan Ali
MAMahmodul Alam
Mahmodul Alam

2 August 2024 in Heliyon
Verified
Journal Article
Open access
NHNahid Hasan
Nahid Hasan
MAMd. Hasan Ali
Md. Hasan Ali
NPNahyan Ahnaf Pratik
Nahyan Ahnaf Pratik
NLNafisa Lubaba
Nafisa Lubaba
MAMiyara Akio
Miyara Akio
Ground heat exchanger (GHE) is the most crucial element of a ground source heat pump (GSHP) system for building cooling and heating by the utilization of geothermal energy. Therefore, intending to enhance the performance of GHE, the present study conducts a computational investigation of the thermal performance of modified spiral tube vertical GHEs. Several modifications of uniform-pitched spiral GHE are made to increase its thermal performance. Some modifications are introduced as variable-pitched spiral tube GHE where spiral inlet pipes are densified in the lower part of GHEs by reducing pitch distance. Conversely, in some modifications, the position of the outlet straight pipe is changed. Water is considered as the working fluid and the inlet temperature of the water is maintained fixed at 300.15 K. After extensive analysis, it is evident that, when the outlet pipe is placed outside of the spiral coil, there is a 7.67 % enhancement in the thermal performance than a traditional uniform-pitched spiral tube GHE. However, modifications like variable-pitched spiral tube GHEs are not significant to improve the thermal performance due to the quick saturation of the ground soil temperature around the GHE pipes. To have a balance between heat transfer rate and pressure drop, thermal performance capability (TPC) and coefficient of performance improvement (COPimprvt) criterion were evaluated and it is found that the uniform-pitched spiral tube GHE along with the outlet pipe at the outside of the spiral provides maximum thermal performance with a maximum TPC value of 1.062 and provides the positive value of COPimprvt criterion. The positive values of COPimprvt indicate that the spiral tube GHEs are energy efficient based on heat transfer and pressure drop. Moreover, spiral GHE with high-density polyethylene (HDPE), concrete pile, and sandy clay outperform the other materials for pipe, backfill, and soil, respectively. Specifically, HDPE pipe, concrete backfill, and sandy clay as soil offer around 7 %, 5 %, and 7.8 % higher thermal performance compared to polyethylene, sand silica, and clay, respectively.

1 October 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
RIRafiqul Islam
Rafiqul Islam
MAMd. Hasan Ali
Md. Hasan Ali
NPNahyan Ahnaf Pratik
Nahyan Ahnaf Pratik
NLNafisa Lubaba
Nafisa Lubaba
MAMiyara Akio
Miyara Akio
To obtain improved thermal performance of flat plate solar collectors, the effect of square and rectangular riser tubes of a flat plate collector (FPC) were numerically investigated and compared with circular riser tube FPC in the present study. For this purpose, a three-dimensional numerical model for FPC collectors has been developed and simulated in CFD software ANSYS FLUENT. Transient thermal performance analysis is carried out to find out the optimum geometrical configuration of the FPC riser tube. The numerical results indicated that using the square-shaped riser tube in FPC improves the collector’s useful heat exchange rate as well as thermal efficiency as compared to the use of circular and rectangular riser tubes. There is a maximum 8.1% higher heat exchange rate of the collector with a square riser tube than a circular riser tube under the same operating conditions. The average efficiency of the collector with the circular tube is 65.95%, whereas the square tube has the highest efficiency of 70.44%. However, the pressure drops through the square and rectangular riser geometry are higher than the circular tube. By making a balance between enhanced heat exchange rate and increased pressure drop, the performance evaluation criterion was evaluated and the square-shaped riser tube having the highest value of 2.65 is better than the other configurations. The results clearly indicate that the collector’s performance is notably influenced by the shape of the riser tube, with a square shape yielding superior performance.

10 November 2024 in International Journal of Thermofluids
Verified
Journal Article
Open access
NCNafisa Riza Chowdhury
Nafisa Riza Chowdhury
ATAbu Hena Toslim
Abu Hena Toslim
MAMd. Hasan Ali
Md. Hasan Ali
AMAkio Miyara
Akio Miyara