The extensive application of power transfer through high-voltage direct current (HVDC) transmission links in smart grid scenarios is due to many factors such as high-power transfer efficiency, decoupled interconnection, control of AC networks, reliable and flexible operation, integration of large wind and photovoltaic (PV)-based off-shore and on-shore farms, cost-effectiveness, etc. However, it is vital to focus on many other aspects like control, protection, coordinated operation, and power management to acquire the above benefits and make them feasible in real-time applications. HVDC protection is needed to focus further on innovative and devoted research because the HVDC system is more vulnerable to system faults and changes in operational conditions in comparison to AC transmission because of the adverse effects of low DC-side impedances and sensitive semi-conductor-based integrated power electronics devices. This paper provides a comprehensive review of the techniques proposed in the last three decades for HVDC protection, analyzing the advantages and disadvantages of each method. The review also examines critical findings and assesses future research prospects for the development of HVDC protection, particularly from the perspective of smart-grid-based power systems. The focus of the review is on bridging the gap between existing protection schemes and topology and addressing the associated challenges and issues. The aim is to inform power engineers and researchers about potential research avenues to tackle the challenges in HVDC protection in smart-grid-based power systems.
1 November 2019 in International Journal of Electrical Power & Energy Systems
The quality of power in modern‐day power system is polluted with increased penetration of converter‐based distributed generations such as wind farm, solar PV system. In such scenarios detection of islanding and power quality disturbances as well as the removal of these from the system is quite crucial for equipment and maintenance personnel safety. Here, a down‐sampling empirical mode decomposition (DEMD) and optimized random forest (RF) machine learning approach are hybridized to detect islanding conditions with reduced non‐detection zone (NDZ) and classify non‐islanding power quality events in a highly wind energy penetrated distribution generation system. DEMD has a special ability to filter out the fundamental signal from the polluted signal and random forest is quite an unbiased non‐linear machine learning approach. Moreover, an improved grey wolf optimization technique is proposed to optimize the parameter of RF. The proposed technique is simulated in MATLAB/Simulink with IEEE 13‐Bus test grid. The efficacy of the proposed method is evaluated through comparative analysis with existing machine learning techniques under normal and noisy environments as well as validated in narrow NDZ with lesser detection time.
The trend of integrating different distributed generation sources into the existing grid have increased the probability of power quality disturbances to a threatening level. Eventually, detection, protection and mitigation of these disturbances are even more challenging. In this regard, the article presents an intelligent power quality disturbance classification scheme using a 2D convolutional neural network designed from a systematic and structural standpoint. A total of 8 singular, 5 complex power quality events are simulated and voltage data collection is made from a test system designed in MATLAB Simulink environment. The three-phase voltage data is converted to a single signal arrangement through a newly proposed Unique Clark’s Transformed Sequence. In addition to that, the scheme completely eliminates the worry of a signal processing stage by proposing a novel scaled matrix image created out of 2-cycle data collected at 6.4kHz sampling frequency that acts as input to the CNN architecture designed in the PYTHON environment. Further, the novelty extended to design a pseudo-real-time setup where the MATLAB environment continuously runs the test system, producing scaled matrix images. These images are saved to a shared directory, enabling a PYTHON loop for prompt event classification through the trained CNN model. The model performance is found to be 100% under ideal conditions. It has also tested under three different noise conditions of 40dB, 30dB and 20dB and obtained an overall accuracy of 98.86% with singular events. Further, the method is also verified for complex and unsymmetrical dataset and found to be equally effective. Additionally, the validation is likewise made with a trivial set of real-time simulated data using OPAL-RT 4510 setup. Finally, the proposed PQ detection scheme is compared with recently published work to express its superiority over other similar studies in terms of classification accuracy.