The circulatory Marangoni flow can alter the contact line deposition in evaporating colloidal droplets with pinned contact line. Marangoni flow can be induced by surfactants or thermal effects. Although both cases have been exclusively investigated, the combined effect of surfactant-induced and thermal Marangoni flows is still unknown. The lattice Boltzmann method is utilized to simulate droplet evaporation and corresponding Marangoni flow. Five equations for hydrodynamics, interface capturing, vapor concentration, temperature field, and surfactant transport are intrinsically coupled with each other. They are simultaneously solved in the lattice Boltzmann framework. A geometrical method is proposed to pin the contact line at the triple point. First, evaporation-induced and thermal Marangoni flows are successfully captured. By incorporating surfactant-induced effects, interesting flow patterns are observed. Considering the combined effect of surfactant and temperature gradient, maximum surfactant concentration and maximum temperature (local minima for surface tension) are found at the top and the edge of the droplet, respectively. The maximum surface tension is consequently located between them, and double-circulation flow is observed. If the thermal effect is eliminated, surfactant local concentrations intermittently converge to steady values so that the edge concentration becomes higher than the apex concentration. Until reaching the steady state, there are two patterns that the flow alternates between: one in the direction of the thermal Marangoni flow and the other in the opposite direction.
Analysis of circulating tumor cells (CTCs) as a tool for monitoring metastatic cancers, early diagnosis, and evaluation of disease prognosis paves the way toward personalized cancer treatment. Developing an effective, feasible, and low-cost method to facilitate CTC isolation is, therefore, vital. In the present study, we integrated magnetic nanoparticles (MNPs) with microfluidics and used them for the isolation of HER2-positive breast cancer cells. Iron oxide MNPs were synthesized and functionalized with the anti-HER2 antibody. The chemical conjugation was verified by Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and dynamic light scattering/zeta potential analysis. The specificity of the functionalized NPs for the separation of HER2-positive from HER2-negative cells was demonstrated in an off-chip test setting. The off-chip isolation efficiency was 59.38%. The efficiency of SK-BR-3 cell isolation using a microfluidic chip with a S-shaped microchannel was considerably enhanced to 96% (a flow rate of 0.5 mL/h) without chip clogging. Besides, the analysis time for the on-chip cell separation was 50% faster. The clear advantages of the present microfluidic system offer a competitive solution in clinical applications.
Controllable accumulation of carbon nanotubes in self-assembly techniques is of critical importance in smart patterning and printed electronics. This study investigates how inclining the substrate and inhibiting the droplet spreading by sharp solid edges can affect the droplet contact angle and pinning time to improve the electrical conductivity and uniformity of the deposited patterns. Rectangular and circular pedestals were employed to investigate the effect of geometry on the deposition characteristics and to incorporate the gravitational effect by varying the substrate inclination angle. The results indicate that confining the droplet contact line to remain pinned to the pedestal edge can significantly alter the width, uniformity, and precision of the deposited patterns. These improvements correspond to the enhancement of the droplet pinning time (due to the edge effect) and to the further increase of the local evaporation rate near the contact line (due to the droplet elevation). By conducting experiments on different rectangular pedestals with varying solid–liquid interfacial areas and comparing their deposition characteristics, a rectangular pedestal with specific dimensions is selected in terms of pattern consistency and material usage efficiency. It is also shown that higher inclination angles further increase the deposited line accumulation density. Combining confinement and inclination techniques yields promising deposited patterns with high consistency and low resistivity, ranging from 8.75 kΩ mm−1 to a minimum of 0.63 kΩ mm−1 for a 3 × 6 mm2 rectangular pedestal.
Droplet generation in microscale has gained enormous attention in recent years especially in the pharmaceutical industry due to their application in targeted drug delivery into droplets. In most of these applications, monodispersity and uniformity of droplets are essential. Microfluidic devices can generate droplets at high throughput, enabling thousands of droplet compound encapsulation per second. The monodispersity of the droplets is ensured hydrodynamically through the dripping regime and their uniformity is controlled by active and passive microflow control methods. Here, we study numerically a microfluidic chip that uses a non-embedded co-flow-focusing geometry, so that the droplet generation throughput can take advantage of the flow-focusing devices while the non-embedded co-flow geometry forecloses the surfactant addition necessity. The continuous and dispersed phases were light mineral oil and water, respectively. We investigated the formation of droplets and studied how changing the external diameter of the chip affects the transition between the dripping regime (which corresponds to monodispersity) and the jetting regime. The number of parameters to be taken into account for the optimization of the device is enormous; therefore, in order to account for the effect of many geometrical and hydrodynamical parameters, we trained an artificial neural network based on our simulation data. Using this neural network, we evaluated droplet formation in 3240 different cases. This approach resulted in a remarkable reduction of computation time, from months to seconds. Examining numerous cases in such a short period lets us choose the optimum geometry and flow rate based on the application. The optimization was able to find the best geometry to extend the region of dripping regime in the flow rate map. Finally, to harness the droplet generation frequency, we also simulated a periodically switched laser and we were able to predict the generation of droplets with the same frequency as the switching frequency. Therefore, altering and controlling the frequency and dimensions of the droplets for a given flow rate ratio could be achieved with this technique, even without satellite droplets.
Our discovery reveals the existence of an optimum SDS/CNT concentration ratio to achieve the highest conductivity of ring deposition for strain sensing.